Outdoor Unit: RKS30/36LVJU, RXS30/36LVJU
SiUS091133
367
Removal Procedure
7.2
Removal of Electrical Box
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the screw on
the stop valve mounting
plate.
2
Remove the screw on
the partition plate (1).
3
Remove the 2 screws
to detach the ground
wires.
Stop valve
mounting plate
(R16641)
Partition plate (1)
(R16917)
Ground wire
(R16642)