background image

ISO14001 assures an effective environmental 
management system in order to help protect 
human•health•and the environment from the potential 
impact of our activities, products and services and to 
assist in maintaining and improving the quality of 
the•environment.

Daikin Europe N.V. is approved by LRQA for its Quality 
Management System in accordance with the ISO9001 
standard. ISO9001 pertains to quality assurance regarding 
design, development, manufacturing as well as to services 
related to the product.

Daikin units comply with the European
regulations that guarantee the safety of
the product.

Zandvoordestraat 300
B-8400 Ostend - Belgium
www.daikineurope.com

EED

E06-1/3 • 

05/2006

Pr

e

p

ar

e

d

 in

 Be

lg

iu

m b

y La

nn

o

o

The present publication is drawn up by way of 
information only and does not constitute an offer 
binding upon Daikin Europe N.V.. Daikin Europe N.V. 
has compiled the content of this publication to the 
best of its knowledge. No express or implied warranty 
is given for the completeness, accuracy, reliability or 
fitness for particular purpose of its content and the 
products and services presented therein. Specifications 
are subject to change without prior notice. Daikin 
Europe N.V. explicitly rejects any liability for any direct 
or indirect damage, In the broadest sense, arising from 
or related to the use and/or interpretation of this 
publication. All content is copyrighted by Daikin 
Europe N.V..

ÉEEDE06-1/3ÇËÍ

Split - Sky Air

Daikin Europe N.V. is participating in the 
EUROVENT Certification Programme. 
Products are as listed in the EUROVENT 
Directory of Certified Products. 

Summary of Contents for FTXS20D3VMW

Page 1: ...technical data FTXS D3VMW_D2VMW Wall Mounted Unit air conditioning systems Split Sky Air ...

Page 2: ..._D2VMW 1 Features 2 2 Specifications 3 For indoor units only 3 Technical Specifications 3 Electrical Specifications 4 3 Dimensional drawing centre of gravity 5 Dimensional drawing 5 Centre of gravity 6 4 Piping diagram 7 5 Wiring diagram 8 Wiring diagram 8 6 Sound data 9 Sound pressure spectrum 9 ...

Page 3: ...aves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid cooling or heating Indoor unit silent operation Silent button on the remote control lowers the operation sound of the indoor unit by 3dB A The new titanium apatite photocatalytic air purification filter increases the active surface area for effective purification and deodorisation ECONO m...

Page 4: ...m m min 6 7 6 7 6 9 9 3 Low m min 4 7 4 7 4 8 7 1 Silent Operation m min 3 9 3 9 4 0 6 2 Heating High m min 9 4 9 4 9 7 11 4 Medium m min 7 6 7 6 7 9 9 4 Low m min 5 8 5 8 6 0 7 4 Silent Operation m min 5 0 5 0 5 2 6 3 Fan Motor Quantity 1 1 1 1 Model KFD 28040 8B KFD 280 40 8B KFD 280 40 8B KFD 280 40 8B Number of steps 5 steps silent and auto Motor Speed cooling High rpm 1250 1250 1270 1580 Medi...

Page 5: ...ity 2 2 2 2 Item Mounting plate Quantity 1 1 1 1 Notes Sound values are measured in an anechoic room Sound pressure level is a relative value depending on the distance and acoustic environment For more details please refer to sound level drawings of this chapter The sound power level is an absolute value indicating the power which a sound source generates 2 3 ELECTRICAL SPECIFICATIONS FTXS20D3VMW ...

Page 6: ...or performance Name plate Terminal block with earth terminal Air flow indoor including mounting plate Cooling dry Required space Heating 50 min 50 min 30 min 3D047237B FTXS50D unit mm Left Rear Right The mark Y shows piping direction Signal receiver Bottom Flaps Front panel fixed screws inside Inside Timer lamp Operation lamp Signal transmitter Infrared remote control Up down automatic Blade angle...

Page 7: ... Indoor Units R 410A FTXS D3VMW_D2VMW 3 Split Sky Air Indoor Units 6 3 Dimensional drawing centre of gravity 3 2 Centre of gravity FTK XS20 25 35DVMW L 4D048210 4D048210D FTK XS50D ...

Page 8: ... fan Field piping 6 4 CuT Field piping 12 7 CuT Fan motor Refrigerant flow Cooling Heating 9 5 CuT Heat exchanger 6 4 CuT Indoor unit 7 0 CuT Maffler assy 7 9 CuT 6 4 CuT 6 4 CuT 4D047913D FTXS50D Indoor unit Heat exchanger Cross flow fan Fan motor Field piping Field piping Refrigerant flow Thermistor on heat exchanger Cooling Heating Maffler assy ...

Page 9: ...th 120 2 Refer to purchasing specification AS303002 unless otherwise specified 3 This drawing was drawn on CAD system 4 Caution Note that operation will restart automatically if the main power supply is turned off and then back on again 3D051652 FTK XS50D g Field wiring Outdoor Indoor Infrared remote control R Protective earth FG Frame ground F1U Fuse H1P H3P Pilot lamp M1F Fan motor M1S Swing mot...

Page 10: ...er frequency Octave band center frequency Octave band sound pressure level 0dB 0 0002µbar Octave band sound pressure level 0dB 0 0002µbar NOTES 1 Measurement was taken in an anechoic room 2 The operation noise measuring method is in accordance with JISC9612 3 Operating conditions Power source 230 V 50 Hz o o H A 39 o o L A 26 4 Operation noise differs with operation and ambient conditions Location...

Page 11: ... Indoor Units R 410A FTXS D3VMW_D2VMW 6 Split Sky Air Indoor Units 10 6 Sound data 6 1 Sound pressure spectrum ...

Page 12: ...in Belgium by Lannoo The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N V Daikin Europe N V has compiled the content of this publication to the best of its knowledge No express or implied warranty is given for the completeness accuracy reliability or fitness for particular purpose of its content and the products and services...

Reviews: