Indoor Unit
SiUS041829E
18
Part 3 Printed Circuit Board Connector Wiring Diagram
Caution
1. Indoor Unit
1.1 FTXR09/12/18TVJUW(S)
Control PCB
(A1P)
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
1)
S21
Connector for centralized control (HA)
2)
S25
Connector for INTELLIGENT EYE sensor PCB (A3P)
3)
S32
Indoor heat exchanger thermistor
4)
S41
Connector for swing motors
5)
S42
Connector for reduction motor (front panel mechanism) and limit
switch
6)
S46
Connector for display/signal receiver PCB (A2P)
7)
S200
Connector for DC fan motor
8)
H1, H2, H3
Connector for terminal strip (indoor - outdoor transmission)
9)
FG
Connector for terminal strip (frame ground)
10)
JB
Jumper for fan speed setting when compressor stops for
thermostat OFF
Refer to page 130 for details.
11)
JC
Jumper for power failure recovery function (auto-restart)
Refer to page 130 for details.
12)
LED A
LED for service monitor (green)
13)
F1U, F2U
Fuse (3.15 A, 250 V)
14)
V1
Varistor
S42
S41
S32
JB
JC
S200
H3
H2
FG
S46
S21
F2U
S25
LED A
V1
F1U
H1
2P357399-6
Summary of Contents for FTXR-T Series
Page 17: ...SiUS041829E Part 2 Specifications 13 1 Specifications 14 Part 2 Specifications...
Page 125: ...SiUS041829E Check Part 6 Service Diagnosis 121 18 class R25105 1 2 3 4 Multimeter...
Page 127: ...SiUS041829E Check Part 6 Service Diagnosis 123 18 class R20704 W V U DC_P1 DC_N1...
Page 143: ...SiUS041829E Operation Limit Part 8 Appendix 139 4 Operation Limit RX09 12 18RMVJU9 3D092209E...