7 Troubleshooting

Operation manual

10

FTXP20~35M5V1B/B9

R32 split series

3P520336-6J – 2020.05

6.8

To take following items into
account before a long idle period

1

Set the mode to 

fan only

 by pressing 

 button to dry the

inside of the unit.

2

After operation stops, turn the breaker off.

3

Clean the air filters and replace them in their original position.

4

Remove the batteries from the user interface.

INFORMATION

It  is  recommended  to  have  periodical  maintenance
performed  by  a  specialist.  For  specialist  maintenance,
contact  your  dealer.  Maintenance  costs  shall  be  borne  by
the customer.

In  certain  operating  conditions  the  inside  of  the  unit  may
get dirty after several seasons of use. This results in poor
performance.

7

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  off  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause breakage, electric shock or fire. Contact your dealer.

The system MUST be repaired by a qualified service person.

Malfunction

Measure

If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does NOT properly work.

Turn OFF the main power
switch.

If water leaks from the unit.

Stop the operation.

The operation switch does NOT work
well.

Turn OFF the power
supply.

If the user interface display indicates the
unit number, the operation lamp flashes
and the malfunction code appears.

Notify your installer and
report the malfunction
code.

If  the  system  does  NOT  operate  properly  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  in  accordance  with  the  following
procedures.

INFORMATION

Refer  to  the  reference  guide  located  on 

http://

www.daikineurope.com/support-and-manuals/product-
information/

 for more troubleshooting tips.

If  after  checking  all  above  items,  it  is  impossible  to  fix  the  problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).

7.1

Symptoms that are NOT system
malfunctions

The following symptoms are NOT system malfunctions:

7.1.1

Symptom: A sound like water flowing is
heard

▪ This sound is caused by the refrigerant flowing in the unit.

▪ This  sound  may  be  generated  when  water  is  flowing  away  from

the unit during cooling or drying operation.

7.1.2

Symptom: A blowing sound is heard

This sound is generated when the direction of the refrigerant flow is
changed (e.g. when switching from cooling to heating).

7.1.3

Symptom: A ticking sound is heard

This sound is generated when the unit slightly expands or contracts
with changes in temperature.

7.1.4

Symptom: A whistling sound is heard

This  sound  is  generated  by  the  refrigerant  flowing  during  defrost
operation.

7.1.5

Symptom: A clicking sound during
operation or idle time is heard

This  sound  is  generated  when  the  refrigerant  control  valves  or
electrical parts operate.

7.1.6

Symptom: A clapping sound is heard

This sound is generated when an external device sucks air out of the
room (e.g. exhaust fan, extractor hood) while the doors and windows
in  the  room  are  closed.  Open  the  doors  or  windows,  or  turn  off  the
device.

7.1.7

Symptom: White mist comes out of a unit
(Indoor unit)

7.1.8

Symptom: The units can give off odours

The  unit  can  absorb  the  smell  of  rooms,  furniture,  cigarettes,  etc.,
and then emit it again.

7.1.9

Symptom: The outdoor fan rotates while
the air conditioner is not in operation

After  operation  has  stopped.

  The  outdoor  fan  continues  to

rotate for another 30 seconds for system protection.

While the air conditioner is not in operation.

 When the outdoor

temperature  is  very  high,  the  outdoor  fan  starts  to  rotate  for
system protection.

7.2

Solving problems based on error
codes

If  the  unit  runs  into  a  problem,  the  user  interface  displays  an  error
code.  It  is  important  to  understand  the  problem  and  to  take
measures before resetting an error code. This should be done by a
licensed installer or by your local dealer.

This  chapter  gives  you  an  overview  of  all  possible  error  codes  and
their descriptions as they appear on the user interface.

For detailed troubleshooting of each error, see the service manual.

Summary of Contents for FTXP20M5V1B

Page 1: ...Operation manual R32 split series English Operation manual R32 split series FTXP20M5V1B FTXP25M5V1B FTXP35M5V1B FTXP20M5V1B9 FTXP25M5V1B9 FTXP35M5V1B9...

Page 2: ...The outdoor fan rotates while the air conditioner is not in operation 10 7 2 Solving problems based on error codes 10 8 Disposal 11 1 About this document Thank you for purchasing this product Please...

Page 3: ...es If the user interface signals operate other appliances move the other appliances or contact your installer Curtains Make sure that the signal between the unit and the user interface is NOT blocked...

Page 4: ...rt both batteries at once 3 Put the cover back 2 3 1 AAA LR03 3 3 To switch between Fahrenheit and Celsius Prerequisite Change this setting only when the temperature is displayed 1 Press and simultane...

Page 5: ...r too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to r...

Page 6: ...ore the Comfort airflow mode disappears from the LCD 4 3 5 Powerful operation This operation quickly maximizes the cooling heating effect in any operation mode You can get the maximum capacity INFORMA...

Page 7: ...cted mode will be resumed CAUTION NEVER expose little children plants or animals directly to the airflow WARNING Do NOT place objects below the indoor and or outdoor unit that may get wet Otherwise co...

Page 8: ...r an operating electric heater NOTICE Maintenance MUST be done by an authorized installer or service agent We recommend performing maintenance at least once a year However applicable legislation might...

Page 9: ...icle filter Ag ion filter INFORMATION Clean the filter with water every 6 months 1 Remove the titanium apatite deodorizing and silver particle filters from the tabs a Tabs 2 Remove the dust from the f...

Page 10: ...e model name of the unit with manufacturing number if possible and the installation date possibly listed on the warranty card 7 1 Symptoms that are NOT system malfunctions The following symptoms are N...

Page 11: ...2020 05 8 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be...

Page 12: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 6J 2020 05 Copyright 20...

Reviews: