![background image](http://html1.mh-extra.com/html/daikin/ftxn25l/ftxn25l_service-manual_4200014085.webp)
Refrigerant Diagram
77
6.6 Installation condition check
Is the
discharged air
short-circuited?
Is the
outdoor heat
exchanger very
dirty?
Yes
Installation condition check.
Change the installation location
,direction or remove obstacles.
Clean the outdoor heat
exchanger.
Yes
Check the
allowable dimensions
of the air suction and
discharge area.
OK
No
No
Yes
NG
Check the outdoor
temperature. (The outdoor
temperature should be
within the operation range.)
Is the
airflow blocked by
obstacles or winds
blowing in the opposite
direction?
No
Change the installation location
,direction or remove obstacles.
Change the installation location
,direction or remove obstacles.
6.7 Outdoor fan system check
Outdoor fan running?
No
DC motor
Yes
No
Fan motor
lead wire connector
disconnected?
Refer to
Appendix A Rotation pulse
check on outdoor unit PCB.
Outdoor fan system is
functioning.
Yes
Check the outdoor fan
system.
Reconnect the connector.
Refer Page 78,item 6.6