Service Diagnosis
34
3.3 Error Indication from Outdoor
3.3.1 ARXN/RXN50/60L , RXB50/60A - 7 Segment Display
It is located inside outdoor unit control panel beside the terminal block. Control panel cover has to be
removed to get access to the 7 segment display.
When there is no error, the compressor running frequency is displayed.
When there is an error, the error code flashes as below:
e
d
o
C
r
o
r
r
E
g
n
i
h
s
a
l
F
n
o
it
a
r
e
p
o
l
a
m
r
o
N
In addition, 7 segment also can be used to retrieve unit operating conditions such as running current, DC
voltage, ambient temperature, indoor air temperature, etc.
By pressing the tact switch, the 7 segment will start to flash from “ ”. Press again, it will show “
” and
subsequent running number show the parameter number.
Then, the 7 segment will flash again showing the parameter measurement.
When the 7 segment display is left untouched for 5 min, the display will light off (Dim).