background image

8 Technical data

Installation manual

12

ATXM20~50+FTXM20~71N2V1B

Daikin room air conditioner

3P482320-8K – 2018.09

8

Technical data

subset

  of  the  latest  technical  data  is  available  on  the  regional  Daikin  website  (publicly  accessible).  The 

full  set

  of  latest  technical  data  is

available on the Daikin extranet (authentication required).

8.1

Wiring diagram

,

A

INDOOR

OUTDOOR

For applied parts and numbering, refer to the wiring diagram on the unit. Part numbering is by Arabic numbers in ascending order for each part 

and is represented in the overview below by symbol “*” in the part code.

Unified Wiring Diagram Legend

CIRCUIT BREAKER

: CONNECTION

: CONNECTOR

: EARTH

FIELD WIRING

: FUSE

INDOOR UNIT

OUTDOOR UNIT

PROTECTIVE EARTH

PROTECTIVE EARTH (SCREW)

: RECTIFIER

RELAY CONNECTOR

SHORT-CIRCUIT CONNECTOR

: TERMINAL

TERMINAL STRIP

WIRE CLAMP

WHT : WHITE
YLW : YELLOW

PNK 

: PINK

PRP, PPL :  PURPLE
RED  : RED

GRN : GREEN
GRY : GREY
ORG : ORANGE

BLK  : BLACK
BLU  : BLUE
BRN : BROWN

A*P 

PRINTED CIRCUIT BOARD

BS* 

PUSHBUTTON ON/OFF, OPERATION SWITCH

BZ, H*O 

BUZZER

C* 

: CAPACITOR

AC*, CN*, E*, HA*, HE*, HL*, HN*, : 

CONNECTION, CONNECTOR

HR*, MR*_A, MR*_B, S*, U, V,
W, X*A, K*R_*
D*, V*D 

DIODE

DB* 

DIODE BRIDGE

DS* 

DIP SWITCH

E*H 

: HEATER

F*U, FU* (FOR CHARACTERISTICS,  :  FUSE
REFER TO PCB INSIDE YOUR UNIT)
FG* 

CONNECTOR (FRAME GROUND)

H* 

: HARNESS

H*P, LED*, V*L 

PILOT LAMP, LIGHT EMITTING DIODE

HAP 

LIGHT EMITTING DIODE (SERVICE MONITOR GREEN)

HIGH VOLTAGE 

HIGH VOLTAGE

IES 

INTELLIGENT EYE SENSOR

IPM* 

INTELLIGENT POWER MODULE

K*R, KCR, KFR, KHuR, K*M 

MAGNETIC RELAY

: LIVE

L* 

: COIL

L*R 

: REACTOR

M* 

STEPPER MOTOR

M*C 

COMPRESSOR MOTOR

M*F 

FAN MOTOR

M*P 

DRAIN PUMP MOTOR

M*S 

SWING MOTOR

MR*, MRCW*, MRM*, MRN* 

MAGNETIC RELAY

: NEUTRAL

n=*, N=* 

NUMBER OF PASSES THROUGH FERRITE CORE

PAM 

PULSE-AMPLITUDE MODULATION

PCB* 

PRINTED CIRCUIT BOARD

PM* 

POWER MODULE

PS 

SWITCHING POWER SUPPLY

PTC* 

THERMISTOR PTC

Q* 

INSULATED GATE BIPOLAR TRANSISTOR 
(IGBT)

Q*DI 

EARTH LEAK CIRCUIT BREAKER

Q*L 

OVERLOAD PROTECTOR

Q*M 

THERMO SWITCH

R* 

: RESISTOR

R*T 

: THERMISTOR

RC 

: RECEIVER

S*C 

LIMIT SWITCH

S*L 

FLOAT SWITCH

S*NPH 

PRESSURE SENSOR (HIGH)

S*NPL 

PRESSURE SENSOR (LOW)

S*PH, HPS* 

PRESSURE SWITCH (HIGH)

S*PL 

PRESSURE SWITCH (LOW)

S*T 

: THERMOSTAT

S*RH 

HUMIDITY SENSOR

S*W, SW* 

OPERATION SWITCH

SA*, F1S 

SURGE ARRESTOR

SR*, WLU 

SIGNAL RECEIVER

SS* 

SELECTOR SWITCH

SHEET METAL  : 

TERMINAL STRIP FIXED PLATE

T*R 

: TRANSFORMER

TC, TRC 

TRANSMITTER

V*, R*V 

VARISTOR

V*R 

DIODE BRIDGE

WRC 

WIRELESS REMOTE CONTROLLER

X* 

: TERMINAL

X*M 

TERMINAL STRIP (BLOCK)

Y*E 

ELECTRONIC EXPANSION VALVE COIL

Y*R, Y*S 

REVERSING SOLENOID VALVE COIL

Z*C 

FERRITE CORE

ZF, Z*F 

NOISE FILTER

Summary of Contents for FTXM20N2V1B

Page 1: ...kin room air conditioner English Installation manual Daikin room air conditioner CTXM15N2V1B ATXM20N2V1B ATXM25N2V1B ATXM35N2V1B ATXM50N2V1B FTXM20N2V1B FTXM25N2V1B FTXM35N2V1B FTXM42N2V1B FTXM50N2V1B FTXM60N2V1B FTXM71N2V1B ...

Page 2: ...condiţia ca acestea să fie utilizate în conformitate cu instrucţiunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z našimi navodili on vastavuses järgmis t e standardi te ga või teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele съответстват на следните стандарти или други нормативни документи при условие че с...

Page 3: ...ference Target audience Authorised installers INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions that you MUST read before installing Format Pap...

Page 4: ...tallation 5 1 Opening the indoor unit 5 1 1 To remove the front panel 1 Hold the front panel by the panel tabs on both sides and open it a a Panel tabs 2 Remove the front panel by sliding it to the left or the right and pulling it toward you Result The front panel shaft on 1 side will be disconnected 3 Disconnect the front panel shaft on the other side in the same manner a a Front panel shaft 5 1 ...

Page 5: ... Finish the installation by securing the mounting plate on the wall using M4 25L screws field supply Class 15 42 Class 50 71 INFORMATION The removed pipe port cover can be kept in the mounting plate pocket Class 15 42 337 810 A 294 44 5 170 68 68 44 5 137 137 337 50 213 237 170 A d e mm a a f h g a a b a c a c a d e Class 50 71 A 990 1040 300 170 60 170 52 52 122 126 5 48 60 435 447 PIPING HOLE CE...

Page 6: ...r as this would damage the front grille 5 2 4 To provide drainage Make sure condensation water can be evacuated properly This involves General guidelines Connecting the drain piping to the indoor unit Checking for water leaks General guidelines Pipe length Keep drain piping as short as possible Pipe size If drain hose extension or embedded drain piping is required use appropriate parts that match ...

Page 7: ... drain leakage from the plug a a 4 mm hexagonal wrench 3 Insert the drain hose on the left side and do not forget to tighten it with the fixing screw otherwise water leakage may occur a b a b a Insulation fixing screw b Drain hose 4 Attach the drain hose to the refrigerant pipes bottom side using adhesive vinyl tape A B C b a A Left side piping B Left back piping C Left bottom piping a Remove the ...

Page 8: ...apart from each other Transmission wiring and power supply wiring may cross but may NOT run parallel In order to avoid any electrical interference the distance between both wirings should ALWAYS be at least 50 mm WARNING Provide adequate measures to prevent that the unit can be used as a shelter by small animals Small animals that make contact with electrical parts can cause malfunctions smoke or ...

Page 9: ...o the definition of Directive 2014 53 EU INFORMATION Install the wireless LAN adapter after finishing the indoor unit installation Refer to 5 6 2 To install the wireless LAN adapter on page 9 Basic parameters What Value Frequency range 2400 MHz 2483 5 MHz Radio protocol IEEE 802 11b g n Radio frequency channel 1 11 Output power 0 dBm 18 dBm Effective radiated power 17 dBm 11b 13 dBm 11g 12 dBm 11n...

Page 10: ...essory 2 To place the wireless LAN adapter into the unit For class 15 42 1 Place the wireless LAN adapter against the hooks 2 Lock the adapter by pressing it down 3 To remove the adapter perform the installation steps in reverse order For class 50 71 1 Place the wireless LAN adapter into the holder 2 Press down on the adapter to fix it in the holder 3 To remove the adapter bend one clamp of the ho...

Page 11: ...nts in the switch box The insulation resistance of the compressor is OK There are NO damaged components or squeezed pipes on the inside of the indoor and outdoor units There are NO refrigerant leaks The correct pipe size is installed and the pipes are properly insulated The stop valves gas and liquid on the outdoor unit are fully open 6 2 To perform a test run Prerequisite Power supply MUST be in ...

Page 12: ...TCH E H HEATER F U FU FOR CHARACTERISTICS FUSE REFER TO PCB INSIDE YOUR UNIT FG CONNECTOR FRAME GROUND H HARNESS H P LED V L PILOT LAMP LIGHT EMITTING DIODE HAP LIGHT EMITTING DIODE SERVICE MONITOR GREEN HIGH VOLTAGE HIGH VOLTAGE IES INTELLIGENT EYE SENSOR IPM INTELLIGENT POWER MODULE K R KCR KFR KHuR K M MAGNETIC RELAY L LIVE L COIL L R REACTOR M STEPPER MOTOR M C COMPRESSOR MOTOR M F FAN MOTOR M...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...3P482320 8K 2018 09 Copyright 2018 Daikin ...

Reviews: