background image

3 About the system

Operation manual

5

35D5V1B6
Split system air conditioners
3P520336-16T – 2021.10

a

c d

ON/OFF

f

g

l

h

i

k

j

e

b

a

Air inlet

b

Air outlet

c

Flap (horizontal blade)

d

Louvers (vertical blades)

e

Front panel

f

Model name plate

g

Room temperature sensor

h

Signal receiver

i

Operation indicator (green)

j

Timer lamp (orange)

k

Indoor unit ON/OFF switch

l

Air filter

ON/OFF button

If the user interface is missing, you can use the ON/OFF button on
the  indoor  unit  to  start/stop  operation.  When  operation  is  started
using this button, the following settings are used:

▪ Operation mode = Automatic

▪ Temperature setting = 25°C

▪ Airflow rate = Automatic

3.2

About the user interface

Direct  sunlight.

  Do  NOT  expose  the  user  interface  to  direct

sunlight.

Dust.

  Dust  on  the  signal  transmitter  or  receiver  will  reduce

sensitivity. Wipe off dust with a soft cloth.

Fluorescent  lights.

  Signal  communication  might  be  disabled  if

fluorescent  lamps  are  in  the  room.  In  that  case,  contact  your
installer.

Other  appliances.

  If  the  user  interface  signals  operate  other

appliances, move the other appliances, or contact your installer.

Curtains.

 Make sure that the signal between the unit and the user

interface is NOT blocked by curtains or other objects.

NOTICE

▪ Do NOT drop the user interface.

▪ Do NOT let the user interface get wet.

3.2.1

Components: User interface

d

a

g

m

h

c

b

n

l

f

e

i

j

k

p
o

a

Signal transmitter

b

LCD display

c

Temperature adjustment button

d

ON/OFF button

e

Vertical swing button

f

Button for

 NOT AVAILABLE

 function horizontal swing

g

Comfort airflow and 

NOT AVAILABLE

 function Intelligent

eye operation button

h

Select button

i

Clock button

j

OFF/ON timer operation buttons

k

Buttons for 

NOT AVAILABLE

 function Weekly timer

operation

l

Button for 

NOT AVAILABLE

 function lamp brightness

setting

m

Button for Econo operation and 

NOT AVAILABLE

function Outdoor unit quiet operation

n

Mode button

o

Powerful button

p

Fan button

3.2.2

Status: User interface LCD

Icon

Description

Operation mode = Automatic

Operation mode = Drying

Operation mode = Heating

Operation mode = Cooling

Operation mode = Fan only

Powerful operation is active

Econo operation is active

Operation is active

Summary of Contents for FTXF25D5V1B6

Page 1: ...Operation manual Split system air conditioners English Operation manual Split system air conditioners FTXF25D5V1B6 FTXF35D5V1B6...

Page 2: ...2 8 1 9 Symptom The outdoor fan rotates while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Th...

Page 3: ...metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteries are disposed o...

Page 4: ...es OFF Otherwise an electrical shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful wit...

Page 5: ...Other appliances If the user interface signals operate other appliances move the other appliances or contact your installer Curtains Make sure that the signal between the unit and the user interface...

Page 6: ...Setting changes Long beep Operation stops 4 Before operation 4 1 To mount the user interface holder 2 b c a a User interface b Screws field supply c User interface holder 1 Choose a place where the s...

Page 7: ...differently depending on the user selection Additional info Outside temperature The system s cooling or heating effect decreases when the outside temperature is too high or too low Defrost operation D...

Page 8: ...e louvers should be facing away from the wall Efficiency will drop if a wall blocks the air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will prov...

Page 9: ...start Result is displayed on the LCD and the timer lamp lights up INFORMATION Each time is pressed the time setting advances by 1 hour The timer can be set between 1 to 9 hours 2 Press to stop Result...

Page 10: ...lculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING The refrigerant inside the uni...

Page 11: ...r then pull it down 2 Pull out the air filters 2 1 3 Wash the air filters with water or clean them with a vacuum cleaner 4 Soak in lukewarm water for about 10 to 15 minutes 5 Install all filters back...

Page 12: ...device sucks air out of the room e g exhaust fan extractor hood while the doors and windows in the room are closed Open the doors or windows or turn off the device 8 1 7 Symptom White mist comes out o...

Page 13: ...erature control High pressure control in cooling mode Compressor system sensor abnormality Position sensor abnormality DC voltage current sensor abnormality Outdoor temperature thermistor abnormality...

Page 14: ......

Page 15: ......

Page 16: ...suyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe stanbul T RK YE Factory Kargal hanbaba OSB Mahallesi Organize Sanayi 1 Sokak No 28 54300 Hendek Sakarya T RK YE 3P520336 16T 2021 10...