SiBE04-101
Service Check Function
Service Diagnosis
85
3. Service Check Function
3.1
ARC417 Series
In the ARC417A series, the temperature display sections on the main unit indicate corresponding codes.
1. When the timer cancel button is held down for 5 seconds, a “00” indication flashes on the temperature
display section.
< Cover in open position >
2. Press the timer cancel button repeatedly until a continuous beep is produced.
The code indication changes in the sequence shown below, and notifies with along beep.
Note:
1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the timer cancel button down for 5 seconds. The code display also
cancels itself if the button is not pressed for 1 minute.
No.
Code
No.
Code
No.
Code
No.
Code
1
00
11
E7
21
UA
31
U1
2
U4
12
C7
22
A5
32
UF
3
F3
13
H8
23
J9
4
E6
14
J3
24
E8
5
L5
15
A3
25
P4
6
A6
16
A1
26
L3
7
E5
17
C4
27
L4
8
LC
18
C5
28
H6
9
C9
19
H9
29
H7
10
U0
20
J6
30
U2
SiBE04-101.book Page 85 Monday, October 15, 2001 3:08 PM