![background image](http://html1.mh-extra.com/html/daikin/ftxd60jv1b/ftxd60jv1b_user-manual_4699899033.webp)
SiBE04-101
General Functions
Main Function
25
Details of the
Action
It can be commanded for J type by means of a user setting to select either any one desired position among
the five-step directions of air flow adjusted on a remote controller, or Auto-swing.
Although the liquid crystal display of the five-step directions of the air flow is common for the modes of
Cooling·Dry/Heating as illustrated above, in fact the range of the swing angle is slightly different in every
operation mode.
The position a user set will be selected among the five positions calculated through the preliminary and
evenly divided into four partitions which were taken from the upper and lower flap angle’s range limits of
each mode.
When Auto-swing is chosen, the flap swings in the swing range which meets the operation mode selected.
Outline of 3-D
Airflow
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of the
entire room. This function is effective for starting the air conditioner.
Details of the
Action
When the horizontal swing and vertical swing are both set to auto mode in J type, the airflow become 3-D
airflow and the horizontal swing and vertical swing motions are alternated. The order of swing motion is
such that it turns counterclockwise, starting from the right upper point as viewed to the front side of the
indoor unit.
1
2
3
4
5
Initial
Initial
3
4
5
2
1
(R1020)
∗
Fan mode is available for the models of cooling-only.
30˚
60˚
Heating mode
0 degree based on
the horizontal line.
(R1021)
15˚
25˚
Cooling / Dry / Fan mode
0 degree based on
the horizontal line.
(R1022)
Heating / Cooling / Dry / Fan mode
60˚
60˚
(R1023)
���
���
���
���
(R1024)
SiBE04-101.book Page 25 Monday, October 15, 2001 3:08 PM