5 Unit installation
Installation manual
5
CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S)
Daikin room air conditioner
3P697375-6B – 2023.05
Note:
Make sure that there are no obstacles within 500 mm under
the infrared signal receiver. They may influence reception
performance of the wireless remote control.
5.2
Mounting the indoor unit
5.2.1
To install the mounting plate
1
Install the mounting plate temporarily.
2
Level the mounting plate.
3
Mark the centres of the drilling points on the wall using a tape
measure. Position the end of tape measure at symbol " ".
4
Finish the installation by securing the mounting plate on the wall
using M4×25L screws (field supply).
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.
44.5
605
17
110
798
150
155
44.5
± 450 mm
± 440 mm
± 400 mm
Ø65
Ø65
f
j
i
d
k
l
m
a
g
f
a
h
h
b
e
c
a
a
a
a
a
a
a
Recommended mounting plate fixing spots
h
Hole for embedded piping Ø65 mm
b
Pocket for the pipe port cover
i
Value for tape measure
c
Liquid pipe end
j
Position for tape measure at symbol " "
d
Gas pipe end
k
Drain hose
e
Use tape measure as shown
l
Liquid pipe
f
Tabs for placing a spirit level
m
Gas pipe
g
Unit center
5.2.2
To drill a wall hole
CAUTION
For walls containing a metal frame or a metal board, use a
wall embedded pipe and wall cover in the feed-through
hole to prevent possible heat, electrical shock, or fire.
NOTICE
Be sure to seal the gaps around the pipes with sealing
material (field supply), in order to prevent water leakage.
1
Bore a 65 mm large feed-through hole in the wall with a
downward slope towards the outside.
2
Insert a wall embedded pipe into the hole.
3
Insert a wall cover into the wall pipe.
Ø65
a b
c
a
Wall embedded pipe
b
Putty
c
Wall hole cover
4
After completing wiring, refrigerant piping and drain piping, do
NOT forget to seal the gap with putty.