Specifications

Standard Accessories : ; Quantity : Titanium apatite photocatalytic air purification filter without frame;
Standard Accessories : Indoor unit fixing screws; Quantity : 2;
Standard Accessories : Titanium apatite photocatalytic air purification filter; Quantity : 2;
Standard Accessories : Installation manual; Quantity : 1;
Standard Accessories : Operation manual; Quantity : 1;
Standard Accessories : Infrared remote control; Quantity : 1;
Standard Accessories : Batteries; Quantity : 2;
Standard Accessories : Remote control holder; Quantity : 1;
Standard Accessories : Mounting plate; Quantity : 1;

2-1 Technical Specifications

FTX20JV

FTX25JV

FTX35JV

Power input

Cooling

Nom.

kW

0.040

Heating

Nom.

kW

0.040

Casing

Colour

White

Dimensions

Unit

Height/Width/Depth

mm

283/770/198

Packed unit

Height/Width/Depth

mm

344/840/263

Weight

Unit

kg

7

Packed unit

kg

11

Heat exchanger

Length

mm

610

Rows

Quantity

2

Fin pitch

mm

1.4

Stages

Quantity

14

Tube type

ø7 Hi-XA

Hi-XA

Fin

Type

ML fin (Multi louver)

Fan

Type

Cross flow fan

Air flow rate

Cooling

High

m³/min

9.1

9.2

9.3

cfm

321

325

328

Nom.

m³/min

7.4

7.6

7.7

cfm

261

268

272

Low

m³/min

5.9

6.0

6.1

cfm

208

212

215

Silent 
operation

m³/min

4.7

4.8

4.9

cfm

166

169

173

Heating High

m³/min

9.4

9.7

10.1

cfm

331

342

356

Nom.

m³/min

7.8

8.0

8.4

cfm

276

283

295

Low

m³/min

6.3

6.7

cfm

222

235

Silent 
operation

m³/min

5.5

5.7

cfm

194

201

Fan motor

Model

MM6C02J2V

Speed

Steps

5 + silent, + auto

Cooling

High/
Medium/
Low/Silent 
operation

rpm

1,210/990/780/630

1,250/1,030/820/630

1,300/1,070/850/680

Heating High/

Medium/
Low/Silent 
operation

rpm

1,260/1,090/920/820

1,300/1,110/920/820

1,340/1,150/960/850

Output

High

W

16

Sound power level

Cooling

High

dBA

55

56

57

Heating

High

dBA

55

56

57

Sound pressure level

Cooling

High/Nom./Low/Silent 
operation

dBA

39/33/25/22

40/33/26/22

41/34/27/23

Heating

Super high/High/Nom./
Low/Silent operation

dBA

-/39/34/28/25

-/40/34/28/25

-/41/35/29/26

Temperature control

Microcomputer control

Air direction control

Right, Left, Horizontal, Downward

Air filter

Type

Removable / washable / mildew proof

Summary of Contents for FTX20JV FTX25JV FTX35JV

Page 1: ...FTX JV Technical Data E E D E N 1 2 1 0 0 W a l l m o u n t e d u n i t Air Conditioners...

Page 2: ...res 2 2 Specifications 3 Technical Specifications 3 Electrical Specifications 4 3 Dimensional drawings 5 Dimensional Drawings 5 4 Centre of gravity 6 Centre of Gravity 6 5 Piping diagrams 7 Piping Dia...

Page 3: ...the user Night set mode saves energy by preventing overcooling or overheating during night time Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on...

Page 4: ...Fin pitch mm 1 4 Stages Quantity 14 Tube type 7 Hi XA Hi XA Fin Type ML fin Multi louver Fan Type Cross flow fan Air flow rate Cooling High m min 9 1 9 2 9 3 cfm 321 325 328 Nom m min 7 4 7 6 7 7 cfm...

Page 5: ...s 2 2 Electrical Specifications FTX20JV FTX25JV FTX35JV Power supply Name V1 Phase 1 Frequency Hz 50 Voltage V 220 230 240 Current 60Hz Nominal running current A Wiring connections 50Hz For power supp...

Page 6: ...3 1 3 Spli t Sky Air Indoor Unit 5 Indoor Unit Wall mounted unit FTX JV 3 Dimensional drawings 3 1 Dimensional Drawings...

Page 7: ...Indoor Unit Wall mounted unit FTX JV 1 4 Spli t Sky Air Indoor Unit 6 4 Centre of gravity 4 1 Centre of Gravity...

Page 8: ...3 1 5 Spli t Sky Air Indoor Unit 7 Indoor Unit Wall mounted unit FTX JV 5 Piping diagrams 5 1 Piping Diagrams...

Page 9: ...Indoor Unit Wall mounted unit FTX JV 1 6 Spli t Sky Air Indoor Unit 8 6 Wiring diagrams 6 1 Wiring Diagrams Single Phase...

Page 10: ...3 1 7 Spli t Sky Air Indoor Unit 9 Indoor Unit Wall mounted unit FTX JV 7 Sound data 7 1 Sound Pressure Spectrum...

Page 11: ...Indoor Unit Wall mounted unit FTX JV 1 7 Spli t Sky Air Indoor Unit 10 7 Sound data 7 1 Sound Pressure Spectrum...

Page 12: ...3 1 7 Spli t Sky Air Indoor Unit 11 Indoor Unit Wall mounted unit FTX JV 7 Sound data 7 1 Sound Pressure Spectrum...

Page 13: ...ted by Daikin Europe N V Daikin s unique position as a manufacturer of air conditioning equipment compressors and refrigerants has led to its close involvement in environmental issues For several year...

Reviews: