background image

• Indoor Unit • Wall mounted unit • FTX-GV

1

4

• Split - Sky Air • Indoor Unit

6

4

Dimensional drawings

4 - 1

Dimensional Drawings

FTX50-60GV

3D055875A

The mark

Left

Rear

Rear

Right

(Space for 

maintenance)

Min. 50

Model name 
plate

Terminal block 
with earth 
terminal (inside)

Wall hole for 

embedded piping 

ø 80 hole

Infrared

remote control

Signal
transmitter

Front grille fixing screws

(inside)

Flaps

Operation lamp

Signal receiver
Indoor unit on/off 
switch
Room temp. thermistor 
(inside)

Intelligent eye sensor

Timer lamp

Home leave lamp

Horizontal blade

(automatic)

Cooling

Heating

Dry

Vertical blade (automatic)

Fan

Wall hole 
ø 80 hole

STANDARD LOCATIONS OF WALL HOLES

BLADE ANGELS

Gas pipe ø12.7 Cut

(the lenght of pipe outside 

the unit: about 430)

Liquid pipe ø 6.4 Cut

(the lenght of pipe outside the 

unit: about 480)

Drain hose for VP13
(connection part 
I.D. 14.0, O.D. 18.0)

(The hose length 
of outside the unit: 
about 530)

Min. 50

(Space for 

maintenance)

Min. 30

(Space for 

performance)

REQUIRED SPACE

Air flow (indoor)

(For performance and maintenance)

shows piping direction

(Including

installation plate)

FTX71GV

3D055876A

The mark

Left

Rear

Rear

Right

(Space for 

maintenance)

Min. 50

Model name 
plate

(Including

installation plate)

Terminal block 
with earth 
terminal (inside)

Wall hole for 

embedded piping 

ø 80 hole

Infrared

remote control

Signal
transmitter

Front grille fixing screws

(inside)

Flaps

Operation lamp

Signal receiver
Indoor unit on/off 
switch
Room temp. thermistor 
(inside)

Intelligent eye sensor

Timer lamp

Home leave lamp

Horizontal blade

(automatic)

Cooling

Heating

Dry

Vertical blade (automatic)

Fan

Wall hole 
ø 80 hole

STANDARD LOCATIONS OF WALL HOLES

BLADE ANGELS

Gas pipe ø15.9 Cut

(the lenght of pipe outside 

the unit: about 430)

Liquid pipe ø 6.4 Cut

(the lenght of pipe outside the 

unit: about 480)

Drain hose for VP13
(connection part 
I.D. 14.0, O.D. 18.0)

(The hose length 
of outside the unit: 
about 530)

Min. 50

(Space for 

maintenance)

Min. 30

(Space for 

performance)

REQUIRED SPACE

Air flow (indoor)

(For performance and maintenance)

shows piping direction

Summary of Contents for FTX-GV

Page 1: ...Air Conditioning Technical Data Wall mounted unit EEDEN13 100 FTX GV...

Page 2: ......

Page 3: ...ications 4 Technical Specifications 4 Electrical Specifications 5 3 Options 6 Options 6 4 Dimensional drawings 7 Dimensional Drawings 7 5 Centre of gravity 8 Centre of Gravity 8 6 Piping diagrams 9 Pi...

Page 4: ...scharge flaps left and right for efficient air and temperature distribution throughout the room Outdoor unit silent operation silent button on the remote control lowers the operation sound of the outd...

Page 5: ...Cross flow fan Air flow rate Cooling High m min 14 7 16 2 17 4 cfm 519 572 614 Nom m min 14 7 16 2 17 4 cfm 519 572 614 Low m min 10 3 11 4 11 6 cfm 364 403 410 Silent operation m min 9 5 10 2 10 6 cf...

Page 6: ...71GV Power supply Name V1 Phase 1 Frequency Hz 50 Voltage V 220 240 Current Nominal running current RLA 50Hz Cooling A 0 16 2 0 15 3 0 15 4 0 19 2 0 18 3 0 17 4 0 21 2 0 20 3 0 19 4 Heating A 0 17 2 0...

Page 7: ...3 1 3 Split Sky Air Indoor Unit 5 Indoor Unit Wall mounted unit FTX GV 3 Options 3 1 Options...

Page 8: ...for maintenance Min 30 Space for performance REQUIRED SPACE Air flow indoor For performance and maintenance shows piping direction Including installation plate FTX71GV 3D055876A The mark Left Rear Re...

Page 9: ...3 1 5 Split Sky Air Indoor Unit 7 Indoor Unit Wall mounted unit FTX GV 5 Centre of gravity 5 1 Centre of Gravity FTX50 71GV 4D065971B B B...

Page 10: ...Indoor Unit Wall mounted unit FTX GV 1 6 Split Sky Air Indoor Unit 8 6 Piping diagrams 6 1 Piping Diagrams...

Page 11: ...Thermistor H1 H3 Harness S1 S38 Connector H1P H3P Pilot lamp S1W Operation switch M1F Fan motor X1M Terminal strip M1S M2S Swing motor Protective earth LED1 LED2 LED3 RECTIFIER Transmission circuit In...

Page 12: ...B G N is already rectified 2 Measuring place measure in anechoic room 3 Operation noise differs with operation and ambient conditions 4 Location of microphone JISC9612 The operation noise measuring m...

Page 13: ...r All dB B G N is already rectified 2 Measuring place measure in anechoic room 3 Operation noise differs with operation and ambient conditions 4 Location of microphone JISC9612 The operation noise mea...

Page 14: ...mpiled the content of this leaflet to the best of its knowledge No express or implied warranty is given for the completeness accuracy re liability or fitness for particular purpose of its content and...

Reviews: