6
Mounting Installation Plate
Ensure that the wall is strong enough to withstand the weight
of the unit. Otherwise, it is necessary to reinforce the wall
with plates, beams or pillars.
Use the level gauge for horizontal mounting, and
fi
x it with
7 suitable screws for FTS20/25JEV1K.
In case the rear piping draws out, drill a hole 65mm in
diameter with a cone drill, slightly lower on the outside wall
(see
fi
gure).
Through the
wall hole
Ø 65mm
Recommended mounting plate
retention spots (7 spots in all)
190
173
61
310
61
Drain hose
position
Gas pipe end
Liquid pipe end
48
45
580
1065
219
40
40
91
45
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for
smooth drainage. Avoid situations that are likely to cause
water to leak.
Mounting plate
Clip
Mark (rear side)
Bottom frame
Front grille
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the installation
plate (Engage the two hooks at the rear top of the indoor unit
with the upper edge of the installation plate). Ensure that the
hooks are properly seated on the installation plate by moving
it to the left and right.
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the mounting plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the front grille)
to release the claws.
Mounting plate
Interconnecting
wires
Hang indoor unit’s hook here.
Wire guide
When stripping the
ends of interconnecting
wires in advance, bind
right ends of wires with
insulating tape.
Recommended Mounting Plate Retention Spots And
Dimensions
Inside
Caulking
Outside
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Wall embedded pipe
(Field supply)
Ø 65
Hole with cone drill
End dipped
into water
Water leaking
Water leaking
Water leaking
Wrong
Wrong
Wrong
Drain
Water Drainage
Water Retention
Correct
Mounting plate
Mounting plate
fi
xing screw
FTS20/25JEV1K
FTS20/25JEV1K
All dimensions are in mm
!
CAUTION
• Do not install the unit at altitude over 2000m for both indoor and outdoor.
1-EN-IM 5WMJ-0811(0)Daikin.indd 6
1-EN-IM 5WMJ-0811(0)Daikin.indd 6
10/18/11 5:15:31 PM
10/18/11 5:15:31 PM