Dry Mode
• When the air humidity is high, the unit can operate in dry
mode. Press <MODE> button and choose <DRY>.
• If the room temperature is 2°C/3.6°F higher than the set
temperature, the air conditioner will operate under
cooling mode until it reaches within the 2°C/3.6°F range
of difference compared to the set temperature before it
converts to dry mode.
• If the room temperature is within the 2°C/3.6°F range
of difference compared to the set temperature, it will
directly operate under dry mode.
• The unit will operate at LOW speed under dry mode.
Air Flow Control
• For more effective air circulation, you can manually
adjust the air discharge grille to the left or right.
• During cool mode operation and dry mode operation, do
not direct the air discharge louver downwards for too long.
If operating continues in this way, condensation may occur
on the louver, thus resulting in drippings.
Frost Prevention
• When the air
fi
lter is dirty, the evaporating temperature
will decrease and eventually cause frosting.
• If the evaporating temperature reaches -1°C/33.8°F, the
unit will trip.
Fan Speed And Rated Cooling Capacity
• The rated cooling capacity is provided at the HIGH fan
speed.
• The cooling capacity is lower when the unit is operating
at MEDIUM and LOW fan speed.
Notes On Flaps And Louvers Angles
• When
“
SWING button
” is selected, the
fl
aps swinging
range depends on the operation mode. (See the
fi
gure.)
ATTENTION
• Always use a remote controller to adjust the
fl
aps angle.
If you attempt to move it forcibly with hand when it
is swinging, the mechanism may be broken.
• Be careful when adjusting the louvers. Inside the air outlet,
a fan is rotating at a high speed.
In COOL, DRY and FAN mode
When stop
operation
Upper limit 55
˚
Lower limit 75
˚
AIR CONDITIONER UNIT OPERATION
OPERATING RANGE
10
60
54
52
50
40
30
20
19
10
14 15
19 20
23
25
COOLING
INDOOR TEMP. WB(
˚
C)
DB: Dry bulb
WB: Wet bulb
OUTDOOR
TEMP
.
DB(
˚
C)