English

Shut off all electrical power before doing any 

• 

maintenance to avoid the risk of serious 
electric shock; never sprinkle or spill water 
or liquids on the unit.

Do not touch the switch with wet fi ngers. 

• 

Touching a switch with wet fi ngers can cause 
electric shock.

Do not allow children to play on or around 

• 

the unit to prevent injury.

The heat exchanger fi ns are sharp enough to 

• 

cut. To avoid injury wear gloves or cover the 
fi ns while working around them.

Do not put a fi nger or other objects into the 

• 

air inlet or air outlet. The fan is rotating at 
high speed and will cause injury.

Check the unit foundation for damage on a 

• 

continuous basis, especially if it has been in 
use for a long time. If left in a damaged con-
dition the unit may cause injury.

Placing a fl ower vase or other containers 

• 

with water or other liquids on the unit could 
cause a shock or fi re if a spill occurs.

Never touch the internal parts of the control-

• 

ler. Do not remove the front panel because 
some parts inside are dangerous to touch. To 
check and adjust internal parts, contact your 
dealer.

Be aware that prolonged, direct exposure to 

• 

cool or warm air from the air conditioner, or 
to air that is too cool or too warm can be 
harmful to your physical condition and 
health.

Ask your dealer to install in a machine room 

 

that has no water drops by raining.
This unit is for indoor use.
Incomplete installation performed by yourself 
may result in a water leakage, electric shock, 
and fi re.

 CAUTION

Do not use the air conditioner or heat pump 

• 

for any other purposes other than comfort 
cooling or heating. Do not use the unit for 
cooling precision instruments, food, plants, 
animals or works of art.

Do not place items under the indoor unit as 

• 

they may be damaged by condensates that 
may form if the humidity is above 80% or if 
the drain outlet gets blocked.

Before cleaning, stop the operation of the 

• 

unit by turning the power off or by pulling the 
supply cord out from its receptacle. Other-
wise, an electric shock and injury may result.

Do not wash the air conditioner or heat pump 

• 

with excessive water. An electric shock or 
fi re may result.

Avoid placing the controller in a spot 

• 

splashed with water. Water entering the con-
troller may cause an electric shock or dam-
age the internal electronic parts.

Do not operate the air conditioner or heat 

• 

pump when using a room-fumigation type of 
insecticide. Failure to observe this could 
cause the chemicals to be deposited in the 
unit and can endanger the health of those 
who are hypersensitive to chemicals.

Do not shut off the power immediately after 

• 

stopping operation. Always wait for at least 
fi ve minutes before shutting off the power. 
Otherwise, water leakage may occur.

The appliance is not intended for use by 

• 

young children or infi rm persons without 
supervision.

The remote controller should be kept away 

• 

from children so they cannot play with it.

Consult with the installation contractor for 

• 

cleaning.

Incorrect cleaning of the inside of the air con-

• 

ditioner or heat pump could make the plas-
tics parts break and cause water leakage or 
electric shock.

Do not touch the air inlet or aluminum fi n of 

• 

the air conditioner or heat pump as they can 
cut and cause injury.

Do not place objects in direct proximity of 

• 

the outside unit. Do not let leaves and other 
debris accumulate around the unit. Leaves 
are a hotbed for small animals which can 
enter the unit. Once inside the unit, animals 
can cause the unit to malfunction, and cause 
smoke or fi re when they make contact with 
electrical parts.

Be sure that children, plants or animals are 

 

not exposed directly to airfl ow from the unit, 
as adverse effects may ensue.

01_EN_3P250362-4B.indd   3

01_EN_3P250362-4B.indd   3

1/5/2012   2:56:51 PM

1/5/2012   2:56:51 PM

Summary of Contents for FTQ18PBVJU

Page 1: ...with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre donn au propri taire de l quipement Le...

Page 2: ...f a j d k i d b f k e Set to Cool Heat 74F 70F Auto This function is not available CENTRAL CONTROL MASTER CONTROLLED SETBACK STANDBY Standard display example 2 1 8 10 6 7 3 4 5 9 3 2 00_CV_3P250362 4...

Page 3: ...the following control system type Two remote controllers control system Two remote controllers control one indoor unit The unit is individually operated NOTE Contact your dealer in case of two remote...

Page 4: ...t utilizing a burner is used in the same room as the air conditioner or heat pump there is the danger of oxygen deficien cy which could lead to an asphyxiation haz ard resulting in serious injury or d...

Page 5: ...rm if the humidity is above 80 or if the drain outlet gets blocked Before cleaning stop the operation of the unit by turning the power off or by pulling the supply cord out from its receptacle Other w...

Page 6: ...uces elec tromagnetic waves h Places with an acid or alkaline mist i Places where fallen leaves can accumulate or where weeds can grow Take snow protection measures Contact your dealer for the details...

Page 7: ...this air conditioner or heat pump and that all electrical work is car ried out by qualified personnel according to local laws and regulations Pay attention to the installation location Are the followi...

Page 8: ...cur rently selected item Display contents are changed to previous screen per page On Off button 8 Press once to operate and press once again to stop Operation lamp 9 Green lamp lights up during operat...

Page 9: ...lains the sequence of operation for the remote controller Operate the buttons according to the procedure Operation button display Displays the location of buttons to be operated Setting Main Menu Air...

Page 10: ...ive minutes for the condensate pump to finishing draining residual water from the unit CHARACTERISTICS OF HEAT MODE The system automatically controls the follow ing operating modes to prevent the redu...

Page 11: ...lled by the master in 9 door unit Setback 10 Please refer to attached manual with remote con troller for another operation OPTIMUM OPERATION 7 Observe the following precautions to ensure the system op...

Page 12: ...e air conditioner or heat pump If the area around the indoor unit is very dusty use a dust proof cover local procurement Cleaning the inside of the indoor unit It is necessary to clean the inside of t...

Page 13: ...tlet are not blocked Remove any obstacle Check if the ground is connected Might there be a broken wire somewhere Contact your dealer if there are any problems Clean the air filter After cleaning the a...

Page 14: ...less of the remote controller indication WHITE MIST COMES OUT OF A UNIT III When humidity is high during cooling op eration In oily or dusty places If the inside of an indoor unit is extremely con tam...

Page 15: ...case and none of the other mentioned malfunctions are evident investigate the system accord ing to the following procedures If the system does not operate at all 1 Check if there is a power failure W...

Page 16: ...e curtains or blinds When there are too many inhabitants in the room when cooling Cooling effect decreases if heat gain of the room is too large The heat source of the room is excessive when cooling C...

Page 17: ...3P250362 4B EM11A010 1201 HT 00_CV_3P250362 4B indd 2 00_CV_3P250362 4B indd 2 1 17 2012 9 39 37 AM 1 17 2012 9 39 37 AM...

Reviews: