background image

[Sticker attachment area]

Attach the SSID&KEY sticker of wireless LAN connecting 

adapter to the sticker attachment area and keep safe.

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

MODELS

FTXM50WVMA 
FTXM60WVMA 
FTXM71WVMA 

FTKM50WVMA 
FTKM60WVMA 
FTKM71WVMA 

   

   

 

Summary of Contents for FTKM20WVMA

Page 1: ...SSID KEY sticker of wireless LAN connecting adapter to the sticker attachment area and keep safe DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXM20WVMA FTXM25WVMA FTXM35WVMA FTXM46WVMA FTKM20W...

Page 2: ...EEKLY TIMER allows you to set on off times and the desired temperature Page 28 INTELLIGENT EYE The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airflow direction If no...

Page 3: ...Basic Operation AUTO DRY COOL HEAT FAN Operation 13 Adjusting the Airflow Rate 15 Adjusting the Airflow Direction 16 Useful Functions MOLD PROOF Operation 17 FLASH STREAMER AIR CLEANING Operation 19...

Page 4: ...r modify the air conditioner yourself as this may result in water leakage electric shock or fire hazards Do not use flammable spray near the air conditioner or otherwise fire may result Do not use a r...

Page 5: ...nel may fall and injury or property damage may result Do not locate obstacles in the route The panel may fall and injury or property damage may result Do not bend or damage the wires The wires may be...

Page 6: ...s switch once to start operation Press once again to stop it For the operation mode setting refer to the following table Model Mode Temperature setting Airflow rate FTXM20 25 35 46 AUTO 25 0 C AUTO FT...

Page 7: ...r outlet Outdoor temperature sensor back Air filter Wireless LAN connecting adapter inside Page 7 34 SSID KEY sticker of wireless LAN connecting adapter Backside of the front panel Fixing tab Panel su...

Page 8: ...om product dmobile compatible Internet line and communicating device Modem router or similar device Wireless LAN access point Application name DAIKIN Mobile Controller free application version 4 0 or...

Page 9: ...reless LAN button POWERFUL button POWERFUL operation Page 23 Wireless LAN button push 5 seconds Wireless LAN connection Page 35 For FTXM20 25 35 46 ARC466A76 For FTKM20 25 35 46 ARC466A77 Display LCD...

Page 10: ...be used for the WEEKLY TIMER operation SELECT button Changes the clock ON OFF TIMER and WEEKLY TIMER settings ECONO QUIET button ECONO OUTDOOR UNIT QUIET operation Page 24 SWING button and MENU butto...

Page 11: ...lacing In some cases when battery consumption is accelerated owing usage conditions signal reception may decline before the LCD begins blinking The batteries supplied with the remote controller are fo...

Page 12: ...day SUN Sunday 3 Press blinks 4 Press to set the clock to the present time Holding down or rapidly increases or decreases the displayed time 5 Press Point the remote controller at the indoor unit when...

Page 13: ...ess or and select menu number 3 Press to confirm the selected setting 4 Press or and select the desired brightness BRIGHTNESS Off BRIGHTNESS High default BRIGHTNESS Low 5 Press again Brightness will b...

Page 14: ...the room by releasing the heat in the room outside Therefore the cooling performance of the air conditioner may be degraded if the outdoor temperature is high Note on DRY operation Eliminates humidit...

Page 15: ...erate level helps save energy Recommended temperature setting for cooling 26 0 28 0 C for heating 20 0 24 0 C Cover windows with a blind or a curtain Blocking sunlight and air from outdoors increases...

Page 16: ...ndoor unit will become quieter In the quiet operation mode the airflow rate is set to a weak level If the temperature dose not reach the desired point change the airflow rate setting If COOL DRY opera...

Page 17: ...ow direction Press and and appear on the LCD The flaps and louvres move in turn To cancel 3 D airflow press either or again The flaps or louvres will stop moving To set the flaps or louvres at the des...

Page 18: ...n is enabled appears on the LCD and the MOLD PROOF lamp lights green when MOLD PROOF operation is in progress The STREAMER lamp lights green and flash streamer air cleaning operation starts Display 6...

Page 19: ...time is short If MOLD PROOF operation does not suit your preference set operation to OFF Page 17 Relation between MOLD PROOF operation and indoor unit lamps Air conditioner MOLD PROOF setting MOLD PRO...

Page 20: ...e STREAMER lamp lights green and flash streamer air cleaning operation starts Display 6 Press to return to the default screen NOTE What is streamer discharge This is a type of plasma discharge compris...

Page 21: ...ficult to warm up COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in COOL DRY operation and in the downward direction while in HEAT operation which will provide a comfo...

Page 22: ...LLIGENT EYE operation and auto swing airflow directions up and down or right and left are set simultaneously priority is given to auto swing airflow directions and INTELLIGENT EYE operation will be op...

Page 23: ...there are people in both areas Due to the position of the sensor people might be exposed to the airflow of the indoor unit if they are close to the front side of the indoor unit If there are people c...

Page 24: ...peration will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation To maximise the coo...

Page 25: ...ration This operation is performed with lower power and therefore may not provide a sufficient cooling heating effect Pressing causes the settings to be cancelled and disappears from the LCD If the po...

Page 26: ...s until the time setting reaches the point you like Each pressing of either button increases or decreases the time setting by 10 minutes Holding down either button changes the setting rapidly 3 Press...

Page 27: ...he time setting rapidly 3 Press again and setting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and setting time disappear from the LCD and day of the week appear on the...

Page 28: ...STEP 2 of 24 HOUR ON OFF TIMER Page 25 26 Timer display mode cannot be changed while or are blinking Press or to stop the blinking Display Combining display modes Different display modes 24 HOUR ON O...

Page 29: ...gs are the same as those for Monday Page 31 6 00 8 30 17 30 22 00 25 0 C 27 0 C Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings for...

Page 30: ...day 2 Press to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set...

Page 31: ...D and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display A reservation made once can be easily copied and the same settings used for another day of the week Refer to Copy mode Pa...

Page 32: ...the selected day of the week will be copied 4 Press to select the destination day of the week 5 Press The reservation will be copied to the selected day of the week The whole reservation of the select...

Page 33: ...witched to setting mode Proceed to Setting mode STEP 4 Page 29 3 Press to exit the confirmation mode appears on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display To...

Page 34: ...will be activated Reservations for each day of the week This function can be used for deleting reservations for each day of the week It can be used while confirming or setting reservations 1 Press Th...

Page 35: ...he above website Application software installation Before downloading the application software for installation please read Configuration on Page 7 For Android phones 1 Open Google Play 2 Search using...

Page 36: ...links briefly The wireless LAN connecting adapter lamp orange blinks for one second 4 Press to return to the default screen To disable 1 While operation is stopped press and hold the button for 5 seco...

Page 37: ...ing blinks briefly The wireless LAN connecting adapter lamp orange blinks more quickly 4 Press the WPS button on your communication device e g router within approximately one minute Please refer to th...

Page 38: ...ANUAL Sticker on the indoor unit SSID KEY sticker Sticker on the cover of the manual 2 Open the DAIKIN Mobile Controller application and select Configure the wireless connection Fig 2 and connect to y...

Page 39: ...performance product quality and life of the streamer Deodorizing filter enzyme blue To purchase the filters Table 1 or to purchase the another type contact the dealer where you bought the air conditio...

Page 40: ...t down 1 Push 2 Pull down 3 Wash the air filters with water or clean them with vacuum cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air...

Page 41: ...et them dry in the shade This filter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years Do not wiring out the filter when removing water from...

Page 42: ...from the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor performance...

Page 43: ...erated when the cabinet and frame of the air conditioner slightly expand or shrink as a result of temperature changes Whistling sound This sound is generated when refrigerant flows during defrosting o...

Page 44: ...progress If this does not suit your preferences set MOLD PROOF to Off The room does not cool down warm up Case Description what to check Air does not come out In HEAT operation The air conditioner is...

Page 45: ...t is discharged with the airflow We recommend that you have the indoor unit cleaned Please consult your dealer Due to streamer discharge the air outlet may emit a slight odour as trace amounts of ozon...

Page 46: ...parts should be done in accordance with the relevant local and national regulations Troubleshooting The following table provides brief descriptions of how to handle problems or carry out connection se...

Page 47: ...R TEMPERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR CC FAULTY HUMIDITY SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START...

Page 48: ...The two dimensional bar code is a manufacturing code 3P651499 1 M21N017 2106 HT Quick Reference MODE On Off FAN Temp Mode Swing...

Page 49: ...Attach the SSID KEY sticker of wireless LAN connecting adapter to the sticker attachment area and keep safe DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXM50WVMA FTXM60WVMA FTXM71WVMA FTKM50W...

Page 50: ...of the week according to your family s life style The WEEKLY TIMER allows you to set on off times and the desired temperature Page 28 INTELLIGENT EYE The INTELLIGENT EYE sensor detects human movement...

Page 51: ...Basic Operation AUTO DRY COOL HEAT FAN Operation 13 Adjusting the Airflow Rate 15 Adjusting the Airflow Direction 16 Useful Functions MOLD PROOF Operation 17 FLASH STREAMER AIR CLEANING Operation 19...

Page 52: ...lt in water leakage electric shock or fire hazards Do not use flammable spray near the air conditioner or otherwise fire may result Do not use a refrigerant other than the one indicated on the outdoor...

Page 53: ...nel may fall and injury or property damage may result Do not locate obstacles in the route The panel may fall and injury or property damage may result Do not bend or damage the wires The wires may be...

Page 54: ...reen Press this switch once to start operation Press once again to stop it For the operation mode setting refer to the following table Model Mode Temperature setting Airflow rate FTXM50 60 71 AUTO 25...

Page 55: ...erature sensor back Air inlet back and side Earth terminal inside Refrigerant pipes and inter unit wire Drain hose SSID KEY sticker of wireless LAN connecting adapter Deodorizing filter enzyme blue Wi...

Page 56: ...om product dmobile compatible Internet line and communicating device Modem router or similar device Wireless LAN access point Application name DAIKIN Mobile Controller free application version 4 0 or...

Page 57: ...Wireless LAN button POWERFUL button POWERFUL operation Page 23 Wireless LAN button push 5 seconds Wireless LAN connection Page 35 For FTXM50 60 71 ARC466A78 For FTKM50 60 71 ARC466A79 Display LCD Dis...

Page 58: ...be used for the WEEKLY TIMER operation SELECT button Changes the clock ON OFF TIMER and WEEKLY TIMER settings ECONO QUIET button ECONO OUTDOOR UNIT QUIET operation Page 24 SWING button and MENU butto...

Page 59: ...lacing In some cases when battery consumption is accelerated owing usage conditions signal reception may decline before the LCD begins blinking The batteries supplied with the remote controller are fo...

Page 60: ...day SUN Sunday 3 Press blinks 4 Press to set the clock to the present time Holding down or rapidly increases or decreases the displayed time 5 Press Point the remote controller at the indoor unit when...

Page 61: ...ess or and select menu number 3 Press to confirm the selected setting 4 Press or and select the desired brightness BRIGHTNESS Off BRIGHTNESS High default BRIGHTNESS Low 5 Press again Brightness will b...

Page 62: ...e room by releasing the heat in the room outside Therefore the cooling performance of the air conditioner may be degraded if the outdoor temperature is high Note on DRY operation Eliminates humidity w...

Page 63: ...erate level helps save energy Recommended temperature setting for cooling 26 0 28 0 C for heating 20 0 24 0 C Cover windows with a blind or a curtain Blocking sunlight and air from outdoors increases...

Page 64: ...ndoor unit will become quieter In the quiet operation mode the airflow rate is set to a weak level If the temperature dose not reach the desired point change the airflow rate setting If COOL DRY opera...

Page 65: ...ow direction Press and and appear on the LCD The flaps and louvres move in turn To cancel 3 D airflow press either or again The flaps or louvres will stop moving To set the flaps or louvres at the des...

Page 66: ...n is enabled appears on the LCD and the MOLD PROOF lamp lights green when MOLD PROOF operation is in progress The STREAMER lamp lights green and flash streamer air cleaning operation starts Display 6...

Page 67: ...time is short If MOLD PROOF operation does not suit your preference set operation to OFF Page 17 Relation between MOLD PROOF operation and indoor unit lamps Air conditioner MOLD PROOF setting MOLD PRO...

Page 68: ...e STREAMER lamp lights green and flash streamer air cleaning operation starts Display 6 Press to return to the default screen NOTE What is streamer discharge This is a type of plasma discharge compris...

Page 69: ...y be difficult to warm up COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in COOL DRY operation and in the downward direction while in HEAT operation which will provide...

Page 70: ...peration CAUTION Do not place large objects near the INTELLIGENT EYE sensor Also keep heating units and humidifiers outside the sensor s detection area This sensor can detect undesirable objects Do no...

Page 71: ...LIGENT EYE operation Application range is as follows 90 55 7m 55 Vertical angle 90 Side view Horizontal angle 110 Top view 7m When the air conditioner is function in INTELLIGENT EYE operation if no pe...

Page 72: ...peration will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation To maximise the coo...

Page 73: ...ration This operation is performed with lower power and therefore may not provide a sufficient cooling heating effect Pressing causes the settings to be cancelled and disappears from the LCD If the po...

Page 74: ...s until the time setting reaches the point you like Each pressing of either button increases or decreases the time setting by 10 minutes Holding down either button changes the setting rapidly 3 Press...

Page 75: ...he time setting rapidly 3 Press again and setting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and setting time disappear from the LCD and day of the week appear on the...

Page 76: ...STEP 2 of 24 HOUR ON OFF TIMER Page 25 26 Timer display mode cannot be changed while or are blinking Press or to stop the blinking Display Combining display modes Different display modes 24 HOUR ON O...

Page 77: ...gs are the same as those for Monday Page 31 6 00 8 30 17 30 22 00 25 0 C 27 0 C Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings for...

Page 78: ...day 2 Press to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set...

Page 79: ...D and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display A reservation made once can be easily copied and the same settings used for another day of the week Refer to Copy mode Pa...

Page 80: ...the selected day of the week will be copied 4 Press to select the destination day of the week 5 Press The reservation will be copied to the selected day of the week The whole reservation of the select...

Page 81: ...witched to setting mode Proceed to Setting mode STEP 4 Page 29 3 Press to exit the confirmation mode appears on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display To...

Page 82: ...will be activated Reservations for each day of the week This function can be used for deleting reservations for each day of the week It can be used while confirming or setting reservations 1 Press Th...

Page 83: ...he above website Application software installation Before downloading the application software for installation please read Configuration on Page 7 For Android phones 1 Open Google Play 2 Search using...

Page 84: ...links briefly The wireless LAN connecting adapter lamp orange blinks for one second 4 Press to return to the default screen To disable 1 While operation is stopped press and hold the button for 5 seco...

Page 85: ...nnection WPS connection If there is a WPS button on your Wi Fi router please follow the below steps 1 While operation is stopped press and hold the button for 5 seconds appears on the LCD SP menu blin...

Page 86: ...Sticker on the cover of the manual Sticker on the indoor unit SSID KEY sticker OPERATION MANUAL m Y g d m d 2 Open the DAIKIN Mobile Controller application and select Configure the wireless connectio...

Page 87: ...aler where you bought the air conditioner The method of cleaning and replacement of the filters may differ depending on the model Refer to the label attached to the separately sold filters themselves...

Page 88: ...t down 1 Push 2 Pull down 3 Wash the air filters with water or clean them with vacuum cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air...

Page 89: ...et them dry in the shade This filter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years Do not wiring out the filter when removing water from...

Page 90: ...from the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor performance...

Page 91: ...f the air conditioner slightly expand or shrink as a result of temperature changes Whistling sound This sound is generated when refrigerant flows during defrosting operation Clicking sound during oper...

Page 92: ...progress If this does not suit your preferences set MOLD PROOF to Off The room does not cool down warm up Case Description what to check Air does not come out In HEAT operation The air conditioner is...

Page 93: ...t is discharged with the airflow We recommend that you have the indoor unit cleaned Please consult your dealer Due to streamer discharge the air outlet may emit a slight odour as trace amounts of ozon...

Page 94: ...ghtning could strike in the neighbourhood stop operation and turn off the circuit breaker to protect the system Disposal requirements Dismantling of the unit and handling of the refrigerant oil and ot...

Page 95: ...R TEMPERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR CC FAULTY HUMIDITY SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START...

Page 96: ...The two dimensional bar code is a manufacturing code MODE On Off FAN Temp Mode Swing 3P651499 2 M21N018 2106 HT Quick Reference...

Reviews: