![background image](http://html1.mh-extra.com/html/daikin/ftkj09nv1sw/ftkj09nv1sw_service-manual_4192924022.webp)
Swing Motors
Si041401EB
20
Removal Procedure
6
Unfasten the 4 hooks
and remove the fan
guard.
Use a sharp tool such as an
awl to unfasten the hooks.
7
Remove the shaft of the
vertical blade from the
swing motor shaft with
a flat screwdriver.
8
Remove the 3 screws
of the cover link ASSY.
Step
Procedure
Points
Hook
Hook
Fan guard
(R20019)
(R23809)
(R23810)
Bottom view
(R23811)
Cover link ASSY
Right view