![background image](http://html1.mh-extra.com/html/daikin/ftkb09axvju/ftkb09axvju_service-manual_2459336039.webp)
Service Diagnosis
31
3.0 Service Diagnosis
3.1 Error Indication from Indoor
3.1.1 Indoor model
FTK(X)N09/12/18/24AX
•
LED display will either be ON during operation or blinking (blue color) when any error occur as in below
table.
•
The blinking pattern does not indicate error details
•
The error details needs to be retrieved from remote controller in error code form.
LED blinks here
SLEEP
(ORANGE)
COOL/HEAT
(BLUE/RED)
TIMER
(WHITE)
Operation / Fault Indication
Blue
Cooling mode
Red
Heating mode
Red
Auto mode in heating operation
Blue
Auto mode in cooling operation
Timer On
Sleep mode on
Blue
Fan mode on
Blue
Dry mode on
Red
Defrost operation
Blue
Unit error
ON
Blinking