Removal of Electrical Box / Vertical Blades (Pattern 2)
Si041139
16
Removal Procedure
2
Unfasten the 3 hooks at
the shaft mounting part
by pressing them with a
flat screwdriver.
3
Remove the vertical
blade ASSY.
Repeat the same procedure
to remove the vertical blade
ASSY on the other side.
Step
Procedure
Points
(R8022)
Hook
(R8023)