![background image](http://html1.mh-extra.com/html/daikin/ftk09nmvju/ftk09nmvju_service-manual_3263258008.webp)
Electrical Box
Si041552E
6
Removal Procedure
2
Pull out the indoor heat
exchanger thermistor.
Be careful not to lose the clip
of the thermistor.
The position of the indoor
heat exchanger thermistor
varies depending on the
model.
3
Release the earth /
ground wires and the
thermistor harness from
the front and the back
slits at the top of the
electrical box.
When reassembling, be sure
to insert the earth / ground
wires in the front slit and
yellow / green wire is above
the green wire and insert the
thermistor harness in the
back slit.
4
Unfasten the 4 hooks
and remove the
electrical box cover.
When reassembling, make
sure that the 4 hooks are
securely fastened.
Step
Procedure
Points
Indoor heat exchanger thermistor
(R21831)
Clip
(R11268)
Electrical box
Earth / ground wire
Thermistor harness
Slit
(R21832)
Front slit
Yellow / green
Green
Back slit
Thermistor
harness
(R21857)
Electrical box cover
Hook
(R21833)