![background image](http://html1.mh-extra.com/html/daikin/ft25-35g/ft25-35g_brochure-and-specs_2459306006.webp)
Outdoor unit
Indoor unit
Specifications are subject to change.
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Sound levels are based on the temperature conditions in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual
operation as a result of ambient conditions.
FT50GV1G
R50GV1G
5.3
18,090
6.9
1,570
FT50GV1G
18.0
635
45/35
R50GV1G
1,530
1.85
735 x 825 x 300
48
290 x 1,050 x 238
12
54
15.9
30
FT60GV1G
R60GV1G
6.6
22,530
9.1
2,030
3.25
FT60GV1G
18.5
653
48/38
R60GV1G
2,850
2.0
770 x 900 x 320
62
1 phase, 230 V, 50 Hz
White
5 steps and automatic
Ivory white
Hermetically sealed rotary type
19.4 to 46
6.4
18.0
15
FT25GV1G
R25GV1G
2.62
8,900
3.5
775
FT25GV1G
9.6
339
36/28
R25GV1G
700
0.82
47
31
9.5
FT35GV1G
R35GV1G
12.7
3.70
12,700
4.9
1,095
3.38
FT35GV1G
9.9
350
39/31
R35GV1G
1,000
1.22
48
37
283 x 800 x 195
9
550 x 765 x 285
25
No.
1
2
Kit name
Air direction adjustment grille
Drain plug
R25/35G
KPW937A4
R50/60G
KPW945A4
KKP937A4
Note: *1. One set includes 5 pieces for 5 units.
Notes: *1. A wiring adaptor (KRP413A1S) is also required for each indoor unit.
*2. The time clocks and other devices should be obtained locally.
*3. The air-purifying filter with photocatalytic deodorising function is a standard accessory. The filter should be replaced after approximately 3 years.
No.
1
2
3
4
Item
5-room centralised controller
Wiring adaptor for time clock/remote controller
(Normal open pulse contact/normal open contact)
Air-purifying filter with photocatalytic deodorising function without frame
Remote controller loss prevention with chain
FT25/35G
FT50/60G
*
1
*
2
*
3
*
1
5-room centralised
controller
KRC72
Air-purifying filter with photocatalytic
deodorising function without frame
KAF970A44
Remote controller loss
prevention with chain
KKF910A4
KRC72
KRP413A1S
KKF910A4
kW
Btu/h
A
W
W/W
mm
m
W
kg
dB (A)
kg
mm
cfm
dB (A)
mm
kg
Capacity
Power supply
Running current
Power consumption
COP
Front panel colour
Airflow rate (H)
Fan speed
Sound levels (H/L)
Dimensions (H x W x D)
Machine weight
Casing colour
Compressor
Refrigerant charge (R-22)
Dimensions (H x W x D)
Machine weight
Operation range
Piping connections
Max. piping length
Max. height difference
Type
Motor output
Liquid
Gas
Drain
Sound levels
Model name
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
CDB
m
3
/min
KAF970A44
KAF952A42
New Powerful Operation
Horizontal Auto-Swing (left and right)
See page 7
See page 7
See page 7
See page 7
See page 8
See page 6
See page 6
See page 8
See page 8
See page 7
See page 7
Refer to the Function List on page 5 to check the functions offered by individual models.
New Powerful Operation boosts airflow to maximum
volume for a 20-minute period. After this, the unit
automatically returns to its previous settings.
Comfortable Airflow
Comfort Control
Lifestyle Convenience
Cleanliness
Timers
Worry Free
The smoothly curved Wide-Angle Louvers provide wide
airflow coverage for effective cooling operation no matter
where the indoor unit is placed in a room.
Power-Airflow Dual Flaps can flatten out during cooling
operation to deliver cool air to the corners of a room.
This function automatically moves the flaps up and down
to distribute air across a room.
The microprocessor automatically controls fan speed to
adjust the room temperature to the set temperature.
This function automatically reduces the level of humidity
while maintaining the preset room temperature.
There is a second On/Off switch on the body of the
indoor unit to prevent any problems if the wireless
remote controller is misplaced.
The air filter is finished with a coating that suppresses the
growth of mould on its surface.
The flat panel models can be cleaned with only the single
pass of a cloth across their smooth surface. The flat panel
can also be easily removed for more thorough cleaning.
This timer can be preset to start and stop at any time
within a 24-hour period. The air conditioner is started/
stopped simply by pressing the On/Off timer button on
the wireless remote controller.
Pressing the Off timer button automatically selects Night
Set Mode. This function prevents any sudden change in
room temperature by gently raising the temperature
before the air conditioner stops, so you can sleep
comfortably.
The air conditioner memorises the settings for mode,
airflow, temperature, etc., and automatically returns to
them when power is restored after a power failure.
Malfunction codes are shown on the digital display panel
of the wireless remote controller for fast and easy
maintenance.
The outdoor unit’s heat exchanger fins are processed
using a special anticorrosion treatment. The surface is
covered with a thin acrylic resin layer to enhance the fins’
resistance to acid rain and salt corrosion.
This filter traps microscopic particles, decomposes
odours and even removes bacteria and viruses. It can be
used for up to 3 years.
Power-Airflow Dual Flaps
Wide-Angle Louvers
Vertical Auto-Swing (up and down)
Auto Fan Speed
Programme Dry Function
Indoor Unit On/Off Switch
Mould-Proof Air Filter
24-Hour On/Off Timer
Night Set Mode
Auto-Restart after Power Failure
Self-Diagnosis with Digital Display
Anticorrosion Treatment of Outdoor Heat
Exchanger Fins
Wipe-Clean Flat Panel
Air-Purifying Filter with Photocatalytic
Deodorising Function
Horizontal Auto-Swing automatically moves the louvres
to the left and right to cover a room with cool air.
11