background image

Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/products/ac/

All rights reserved

c

Warning

z

Daikin products are manufactured for export to numerous countries throughout the world. Prior to 
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this 
product conforms to the applicable standards, and is suitable for use, in the region where the product 
will be used. This statement does not purport to exclude, restrict or modify the application of any local 
legislation.

z

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. 
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

z

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or 
contractor to install those parts and accessories. Use of unauthorised parts and accessories or 
improper installation of parts and accessories can result in water or refrigerant leakage, electrical 
shock, fire or explosion.

z

Read the user's manual carefully before using this product. The user's manual provides important 
safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install 

the outdoor unit close to the sea shore, contact your local distributor.

Dealer

z

Specifications, designs and other content appearing in this brochure are current as of May 2016 but subject to change without notice.

Si041265EC

05/2016 AK.B

Summary of Contents for FT15LV14

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Indoor Unit Non Inverter Wall Mounted Type 1 5 2 0 2 5 3 5 kW Class Si041265EC ...

Page 2: ...oval Procedure Indoor Unit zCooling Only FT15LV14 FT20LV14 FT25LV14 FTE15LV1 FTE20LV1 FTE25LV1 FTE20MV1V FTE25MV1V FTNE15MV1 FTNE20MV1 FTNE25MV1 FTNE35MV1 FTNE15MV14 FTNE20MV14 FTNE25MV14 FTNE35MV14 FTNE25MV18 FTNE35MV18 ...

Page 3: ...s 1 Air Filters Front Panel 2 2 Front Grille 3 3 Horizontal Blades Vertical Blade ASSYs 4 4 Electrical Box PCBs Swing Motor 5 5 Indoor Heat Exchanger 8 6 Fan Motor Fan Rotor 10 Note The illustrations may be slightly different depending on the model ...

Page 4: ... panel to the position where it stops 2 Remove the air filter Left and right filters are interchangeable When reassembling insert the air filter along the guides 2 Remove the front panel 1 2 Open the front panel fully Push the shafts towards the inside to release 3 Remove the front panel When reassembling the front panel fit the shafts one by one into the grooves and fully push them into position ...

Page 5: ...ep Procedure Points 1 Remove the 2 screws 2 Unfasten the 2 hooks on the top 3 Remove the front grille When reassembling make sure that all hooks are securely fastened R18500 Front grille Hook R2519 R2521 In case that the hooks can not be pressed from above remove the front grille while pushing the hook from the space between the front grille and the indoor heat exchanger ...

Page 6: ...osition 3 4 Unfasten the right shaft and remove the horizontal blade small Remove the horizontal blade large in the same way Installation procedure 1 Fit the horizontal blade to the right shaft first Make sure to rotate the horizontal blade so the shaft fits correctly 2 Fit the horizontal blade to the center and left shafts 2 Remove the vertical blade ASSYs Each vertical blade ASSY has 5 fins whic...

Page 7: ...ng wires Remove the screw and then the wire fixture 3 4 Disconnect the connectors Pull out the indoor heat exchanger thermistor S1 CN_FAN fan motor S7 CN_FANFB fan motor S6 CN_STP swing motor 5 Remove the screw on the terminal board 6 Remove the screw and then the electrical box Wire fixture Connecting wire R18503 R21155 Indoor heat exchanger thermistor S1 CN_FAN S7 CN_FANFB S6 CN_STP R18505 Termi...

Page 8: ... plate 2 Unfasten the 2 hooks 3 Slide the electrical box cover to the left and remove the electrical box cover 4 Unfasten the 4 hooks on the back of the signal receiver PCB Step Procedure Points Shield plate R18507 Hook Hook R21157 Push here R18509 Electrical box cover Hook Signal receiver PCB R18502 ...

Page 9: ...and remove the signal receiver PCB Unfasten the 2 hooks at the bottom and remove the control PCB There are 2 hooks also at the top of the control PCB 3 Remove the swing motor 1 Remove the 2 screws and then the swing motor Step Procedure Points R23376 Control PCB Signal receiver PCB Hook S26 CN_DSP1 R21158 Swing motor R2543 ...

Page 10: ...leaks repair the spot of leaking then collect all refrigerant from the unit After conducting vacuum drying recharge proper amount of refrigerant From the viewpoint of global environmental protection make sure to use a vacuum pump for air purging Step Procedure Points 1 2 Remove the 2 screws which fix the indoor heat exchanger to the installation plate Disconnect the drain hose Place a plastic shee...

Page 11: ...emoval Procedure 9 6 Slightly pull out the auxiliary piping 7 Unfasten the 2 hooks on the left side 8 Unfasten the 2 hooks on the right side and remove the indoor heat exchanger Step Procedure Points R2548 R21159 Hook R2550 R18651 Hook ...

Page 12: ...tor provide as much as 5 mm 0 2 inch of play between the side face of the rotor and the bottom frame 1 Insert the fan motor allowing for approx 5 mm 0 2 inch of play 2 Tighten the fan rotor screw until it stops Then give the screw one more turn 3 If the fan rotor rotates appropriately tighten the screw completely 4 If not repeat the procedure from 1 3 Loosen the screw 4 Remove the fan motor and th...

Page 13: ... Fan Rotor Removal Procedure 11 5 Remove the screw on the left side panel 6 Unfasten the hook and remove the left side plate 7 Remove the bearing Step Procedure Points R21160 R21161 Hook Left side plate R2564 Bearing R2565 ...

Page 14: ...ion Revised contents 02 2013 Si041265 First edition 12 2013 Si041265EA Model addition FTE15 20 25LV1 FTE20 25MV1V 12 2014 Si041265EB Model addition FTNE15 20 25 35MV1 FTNE15 20 25 35MV14 05 2016 Si041265EC Model addition FTNE25 35MV18 ...

Page 15: ...sories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage electrical shock fire or explosion z Read the user s manual carefully before using this product The user s manual provides important safety instruc...