background image

Indoor Heat Exchanger

Si041265EC

8

Removal Procedure

5. Indoor Heat Exchanger

Warning

Š

Be sure to wait for 10 minutes or more after turning off all power supplies before 
disassembling work.

Š

In pump-down work, be sure to stop the compressor before disconnecting the 
refrigerant pipe. If the refrigerant pipe is disconnected with the compressor operating 
and the stop valve open, air may be sucked in and may generate an over-pressure in 
refrigeration cycle, thus resulting in pipe rupture or accidental injury.

Š

When removing or reinstalling the indoor heat exchanger, be sure to wear gloves or 
wrap the indoor heat exchanger with cloths. (You may be injured by the fins.)

Caution

Š

Be sure to conduct pump down operation before disassembling the refrigerant pipe.

Š

If the refrigerant leaks, repair the spot of leaking, then collect all refrigerant from the 
unit. After conducting vacuum drying, recharge proper amount of refrigerant.

Š

From the viewpoint of global environmental protection, make sure to use a vacuum 
pump for air purging.

Step

Procedure

Points

1

2

Remove the 2 screws 
which fix the indoor 
heat exchanger to the 
installation plate.

Disconnect the drain 
hose.

„

Place a plastic sheet around 
the drain pan to prevent 
wetting the floor with 
remaining drain.

„

If the drain hose is 
embedded in the wall, 
disconnect the drain hose 
beforehand.

3

4

Disconnect the gas 
piping and the liquid 
piping.

Remove the indoor unit 
from the installation 
plate.

„

Hold the indoor unit up with a 
piece of wood.

„

Carry out the removal works 
with 2 wrenches.

„

When the pipings are 
disconnected, protect the 
openings of both the pipes 
and the indoor unit from 
moisture intrusion.

5

Unfasten the hook and 
remove the piping 
fixture on the back.

Drain hose

(R18764)

(R2545)

(R18760)

Piping fixture

Summary of Contents for FT15LV14

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Indoor Unit Non Inverter Wall Mounted Type 1 5 2 0 2 5 3 5 kW Class Si041265EC ...

Page 2: ...oval Procedure Indoor Unit zCooling Only FT15LV14 FT20LV14 FT25LV14 FTE15LV1 FTE20LV1 FTE25LV1 FTE20MV1V FTE25MV1V FTNE15MV1 FTNE20MV1 FTNE25MV1 FTNE35MV1 FTNE15MV14 FTNE20MV14 FTNE25MV14 FTNE35MV14 FTNE25MV18 FTNE35MV18 ...

Page 3: ...s 1 Air Filters Front Panel 2 2 Front Grille 3 3 Horizontal Blades Vertical Blade ASSYs 4 4 Electrical Box PCBs Swing Motor 5 5 Indoor Heat Exchanger 8 6 Fan Motor Fan Rotor 10 Note The illustrations may be slightly different depending on the model ...

Page 4: ... panel to the position where it stops 2 Remove the air filter Left and right filters are interchangeable When reassembling insert the air filter along the guides 2 Remove the front panel 1 2 Open the front panel fully Push the shafts towards the inside to release 3 Remove the front panel When reassembling the front panel fit the shafts one by one into the grooves and fully push them into position ...

Page 5: ...ep Procedure Points 1 Remove the 2 screws 2 Unfasten the 2 hooks on the top 3 Remove the front grille When reassembling make sure that all hooks are securely fastened R18500 Front grille Hook R2519 R2521 In case that the hooks can not be pressed from above remove the front grille while pushing the hook from the space between the front grille and the indoor heat exchanger ...

Page 6: ...osition 3 4 Unfasten the right shaft and remove the horizontal blade small Remove the horizontal blade large in the same way Installation procedure 1 Fit the horizontal blade to the right shaft first Make sure to rotate the horizontal blade so the shaft fits correctly 2 Fit the horizontal blade to the center and left shafts 2 Remove the vertical blade ASSYs Each vertical blade ASSY has 5 fins whic...

Page 7: ...ng wires Remove the screw and then the wire fixture 3 4 Disconnect the connectors Pull out the indoor heat exchanger thermistor S1 CN_FAN fan motor S7 CN_FANFB fan motor S6 CN_STP swing motor 5 Remove the screw on the terminal board 6 Remove the screw and then the electrical box Wire fixture Connecting wire R18503 R21155 Indoor heat exchanger thermistor S1 CN_FAN S7 CN_FANFB S6 CN_STP R18505 Termi...

Page 8: ... plate 2 Unfasten the 2 hooks 3 Slide the electrical box cover to the left and remove the electrical box cover 4 Unfasten the 4 hooks on the back of the signal receiver PCB Step Procedure Points Shield plate R18507 Hook Hook R21157 Push here R18509 Electrical box cover Hook Signal receiver PCB R18502 ...

Page 9: ...and remove the signal receiver PCB Unfasten the 2 hooks at the bottom and remove the control PCB There are 2 hooks also at the top of the control PCB 3 Remove the swing motor 1 Remove the 2 screws and then the swing motor Step Procedure Points R23376 Control PCB Signal receiver PCB Hook S26 CN_DSP1 R21158 Swing motor R2543 ...

Page 10: ...leaks repair the spot of leaking then collect all refrigerant from the unit After conducting vacuum drying recharge proper amount of refrigerant From the viewpoint of global environmental protection make sure to use a vacuum pump for air purging Step Procedure Points 1 2 Remove the 2 screws which fix the indoor heat exchanger to the installation plate Disconnect the drain hose Place a plastic shee...

Page 11: ...emoval Procedure 9 6 Slightly pull out the auxiliary piping 7 Unfasten the 2 hooks on the left side 8 Unfasten the 2 hooks on the right side and remove the indoor heat exchanger Step Procedure Points R2548 R21159 Hook R2550 R18651 Hook ...

Page 12: ...tor provide as much as 5 mm 0 2 inch of play between the side face of the rotor and the bottom frame 1 Insert the fan motor allowing for approx 5 mm 0 2 inch of play 2 Tighten the fan rotor screw until it stops Then give the screw one more turn 3 If the fan rotor rotates appropriately tighten the screw completely 4 If not repeat the procedure from 1 3 Loosen the screw 4 Remove the fan motor and th...

Page 13: ... Fan Rotor Removal Procedure 11 5 Remove the screw on the left side panel 6 Unfasten the hook and remove the left side plate 7 Remove the bearing Step Procedure Points R21160 R21161 Hook Left side plate R2564 Bearing R2565 ...

Page 14: ...ion Revised contents 02 2013 Si041265 First edition 12 2013 Si041265EA Model addition FTE15 20 25LV1 FTE20 25MV1V 12 2014 Si041265EB Model addition FTNE15 20 25 35MV1 FTNE15 20 25 35MV14 05 2016 Si041265EC Model addition FTNE25 35MV18 ...

Page 15: ...sories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage electrical shock fire or explosion z Read the user s manual carefully before using this product The user s manual provides important safety instruc...

Reviews: