The movable limit of the flap is changeable. 
Contact your Daikin dealer for details.

Press the AIR FLOW DIRECTION ADJUST 

button to select the air direction as shown 

below.

The AIR FLOW FLAP display 
swings as shown below and the 
air flow direction continuously 
varies. (Automatic swing set-
ting)

Press AIR FLOW DIRECTION 
ADJUST button to select the air 
direction of your choice.

The AIR FLOW FLAP display 
stops swinging and the air flow 
direction is fixed (Fixed air flow 
direction setting).

MOVEMENT OF THE AIR FLOW FLAP

For the following conditions, micro computer controls 
the air flow direction so it may be different from the dis-
play.

Operation mode includes automatic operation.

Operation 

mode

Cooling

Heating

Operation 

condition

When operating 
continuously at 
horizontal air 
flow direction

When room 
temperature is 
higher than the set 
temperature

At defrost opera-
tion
(Air is blown 
horizontally to pre-
vent the cool air 
from being blown 
directly onto any-
one in the room.)

Up and down adjustment

swing

Operate in the following order.

The timer is operated in the following two ways.

Programming the stop time  (

) .... The sys-

tem stops operating after the set time has elapsed.

Programming the start time (

) .... The sys-

tem starts operating after the set time has elapsed. 

The timer can be programmed a maximum of 
72 hours.

The start and the stop time can be simultaneously 
programmed.

TIMER MODE START/STOP

Press the TIMER MODE START/STOP button 

several times and select the mode on the dis-

play.

The display flashes.
For setting the timer stop .... “

For setting the timer start .... “

PROGRAMMING TIME

Press the PROGRAMMING TIME button and set 

the time for stopping or starting the system.

When this button is pressed, the time 
advances by 1 hour.

When this button is pressed, the time 
goes backward by 1 hour.

TIMER ON/OFF

Press the TIMER ON/OFF button.

The timer setting procedure ends. 
The display “ 

 or 

 ” changes from flash-

ing light to a constant light.

 Refer to figure 4 on page [1] 

NOTE

When setting the timer Off and On at the same time, 
repeat the above procedure from    to   once again.

When the timer is programmed to stop the system 
after 3 hours and start the system after 4 hours, the 
system will stop after 3 hours and then 1 hour later 
the system will start.

After the timer is programmed, the display shows 
the remaining time.

Press the TIMER ON/OFF button once again to 
cancel programming. The display vanishes.

PROGRAM TIMER OPERATION

1

2

3

1

3

01_EN_3P083810-1W.fm  Page 6  Friday, October 14, 2005  1:56 PM

Summary of Contents for FHYCP100DVE

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted Multi flow Cassette type FHYCP50DVE FHYCP71DVL FHYCP60DVE FHYCP100DVL FHYCP71DVE FHYCP125DVL FHYCP100DVE FHYCP140DVL FHYCP125DVE 0...

Page 2: ...EST C hr hr TEST NOT AVAILABLE L H 2 10 11 3 1 4 5 6 7 8 14 15 16 17 18 19 20 21 22 12 9 13 a b c d e e f g h i k e f l d j RZP100 125 140 RZP71 C hr H 00_CV_3P083810 1W_2 fm Page 1 Tuesday October 4...

Page 3: ...cuidadosamente el manual de funcionamiento antes de utilizar el acondicionador de aire Dicho manual le indi car c mo utilizar adecuadamente la m quina y le ayudar en caso de aver a Despu s de leer el...

Page 4: ...Confirm the following if your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units All indoor units are equally set Two remote control...

Page 5: ...tioner Incomplete installation may result in a water leakage electric shock and fire The refrigerant in the air conditioner is safe and normally does not leak If the refrigerant leaks inside the room...

Page 6: ...TURE RZP71 DV1 VAL RZP100 DV1 VAL RZP125 DV1 TAL RZP140 DTAL TEMPERA TURE HUMID ITY D B 21 to 35 80 or below D B 5 to 50 W B 14 to 25 HEATING DB Dry bulb temperature WB Wet bulb temperature The setti...

Page 7: ...MED TIME This display shows the PROGRAMMED TIME of the system start or stop hr hr 8 DISPLAY SET TEMPERATURE This display shows the set temperature 9 DISPLAY FAN SPEED This display shows the set fan sp...

Page 8: ...M DRY OPERATION 1 2 After 6 to 8 minutes maximum 10 minutes of DEFROST OPERATION the system returns to HEATING OPERATION Regarding outside air temperature and heat ing capacity The heating capacity of...

Page 9: ...ating after the set time has elapsed Programming the start time The sys tem starts operating after the set time has elapsed The timer can be programmed a maximum of 72 hours The start and the stop tim...

Page 10: ...NING ACCESS TO TERMINAL DEVICES ALL POWER SUPPLY CIRCUITS MUST BE INTERRUPTED To clean the air conditioner be sure to stop oper ation and turn the power switch off Otherwise an electric shock and inju...

Page 11: ...ocedure for closing Fig 3 Fig 4 2 Detach the suction grille Open the suction grille 45 degrees and lift it upward 3 Detach the air filter Refer to HOW TO CLEAN THE AIR FILTER Refer to Fig 2 4 Clean th...

Page 12: ...an speed is different from the setting Pressing the fan speed control button does not change the fan speed When the room temperature reaches the set temperature in heating mode the outdoor unit stops...

Page 13: ...f the above mentioned malfunctions is evident investigate the system according to the following procedures 1 If the system does not operate at all Check if there is a power failure Wait until power is...

Page 14: ...3P083810 1W EM01A088E 0512 HT 00_CV_3P083810 1W_1 fm Page 1 Tuesday October 11 2005 10 32 AM...

Reviews: