VI. DUST FROM THE UNITS

• Dust may blow out from the unit after starting 

operation from long resting time.

Dust absorbed by the unit blows out.

VII.THE UNITS GIVE OFF ODORS

The unit absorbs the smell of rooms, furniture, 
cigarettes, etc., and then emits them.

VIII.THE LIQUID CRYSTAL OF THE REMOTE 

CONTROLLER SHOW “

• It happens immediately after the main power 

supply switch is turned on.

This shows that the remote controller is in nor-
mal condition. 
This continues temporary.

I. If one of the following malfunctions occurs,

take the measures shown below and contact

your Daikin dealer.

The system must be repaired by a qualified service 
person. 

WARNING

When the air conditioner is in abnormal con-

ditions (smell of something burning, etc), 

unplug the power cord from the outlet, and 

contact your dealer

Continued operation under such circumstances 

may result in a failure, electric shock, and fire.

If a safety device such as a fuse, a breaker, or an 
earth leakage breaker frequently actuates, or ON/
OFF switch does not properly work.

Measure: 

 Turn off the main power switch.

If water leaks from unit.

Measure:

  Stop the operation.

If the display “ 

 ” (INSPECTION), “UNIT No.”, 

and the OPERATION lamp flash and the “MAL-
FUNCTION CODE” appears.

10. TROUBLE SHOOTING

OPERATION lamp

INSPECTION

display

MALFUNCTION

CODE

INDOOR UNIT No. in which a

malfunction occurs

UNIT   No.

C

L

  H     

Measure:

 Notify your Daikin dealer and inform 

him/her of the display.

II. If the system does not properly operate 

except for the above mentioned case, and 

none of the above mentioned malfunctions is 

evident, investigate the system according to 

the following procedures.

1. If the system does not operate at all.

Check if there is a power failure.
Wait until power is restored. If power failure 
occurs during operation, the system automati-
cally restarts immediately after the power sup-
ply recovers.

Check if the fuse has blown or breaker has worked. 
Change the fuse or set the breaker.

2. If the system stops operating after operating 

the system.

Check if the air inlet or outlet of outdoor or 
indoor unit is blocked by obstacles.
Remove the obstacle and make it well-venti-
lated.

Check if the air filter is clogged.
Ask a qualified service person to clean the air 
filters (Refer to MAINTENANCE).

3. The system operates but it does not suffi-

ciently cool or heat.

If the air inlet or outlet of the indoor or the out-
door unit is blocked with obstacles.
Remove the obstacle and make it well-venti-
lated. 

If the air filter is clogged.
Ask a qualified service person to clean the air 
filters (Refer to MAINTENANCE).

If the set temperature is not proper (Refer to 
ADJUSTMENT).

If the FAN SPEED button is set to LOW 
SPEED (Refer to ADJUSTMENT).

If the air flow angle is not proper (Refer to 
ADJUSTING THE AIR FLOW DIRECTION).

If the doors or the windows are open. Shut doors 
or windows to prevent wind from coming in.

If direct sunlight enters the room (when cooling).
Use curtains or blinds.

When there are too many inhabitants in the 
room (when cooling).
Cooling effect decreases if heat gain of the 
room is too large.

If the heat source of the room is excessive 
(when cooling).
Cooling effect decreases if heat gain of the 
room is too large.

01_EN_3P083810-1W.fm  Page 10  Friday, October 14, 2005  1:56 PM

Summary of Contents for FHYCP100DVE

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted Multi flow Cassette type FHYCP50DVE FHYCP71DVL FHYCP60DVE FHYCP100DVL FHYCP71DVE FHYCP125DVL FHYCP100DVE FHYCP140DVL FHYCP125DVE 0...

Page 2: ...EST C hr hr TEST NOT AVAILABLE L H 2 10 11 3 1 4 5 6 7 8 14 15 16 17 18 19 20 21 22 12 9 13 a b c d e e f g h i k e f l d j RZP100 125 140 RZP71 C hr H 00_CV_3P083810 1W_2 fm Page 1 Tuesday October 4...

Page 3: ...cuidadosamente el manual de funcionamiento antes de utilizar el acondicionador de aire Dicho manual le indi car c mo utilizar adecuadamente la m quina y le ayudar en caso de aver a Despu s de leer el...

Page 4: ...Confirm the following if your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units All indoor units are equally set Two remote control...

Page 5: ...tioner Incomplete installation may result in a water leakage electric shock and fire The refrigerant in the air conditioner is safe and normally does not leak If the refrigerant leaks inside the room...

Page 6: ...TURE RZP71 DV1 VAL RZP100 DV1 VAL RZP125 DV1 TAL RZP140 DTAL TEMPERA TURE HUMID ITY D B 21 to 35 80 or below D B 5 to 50 W B 14 to 25 HEATING DB Dry bulb temperature WB Wet bulb temperature The setti...

Page 7: ...MED TIME This display shows the PROGRAMMED TIME of the system start or stop hr hr 8 DISPLAY SET TEMPERATURE This display shows the set temperature 9 DISPLAY FAN SPEED This display shows the set fan sp...

Page 8: ...M DRY OPERATION 1 2 After 6 to 8 minutes maximum 10 minutes of DEFROST OPERATION the system returns to HEATING OPERATION Regarding outside air temperature and heat ing capacity The heating capacity of...

Page 9: ...ating after the set time has elapsed Programming the start time The sys tem starts operating after the set time has elapsed The timer can be programmed a maximum of 72 hours The start and the stop tim...

Page 10: ...NING ACCESS TO TERMINAL DEVICES ALL POWER SUPPLY CIRCUITS MUST BE INTERRUPTED To clean the air conditioner be sure to stop oper ation and turn the power switch off Otherwise an electric shock and inju...

Page 11: ...ocedure for closing Fig 3 Fig 4 2 Detach the suction grille Open the suction grille 45 degrees and lift it upward 3 Detach the air filter Refer to HOW TO CLEAN THE AIR FILTER Refer to Fig 2 4 Clean th...

Page 12: ...an speed is different from the setting Pressing the fan speed control button does not change the fan speed When the room temperature reaches the set temperature in heating mode the outdoor unit stops...

Page 13: ...f the above mentioned malfunctions is evident investigate the system according to the following procedures 1 If the system does not operate at all Check if there is a power failure Wait until power is...

Page 14: ...3P083810 1W EM01A088E 0512 HT 00_CV_3P083810 1W_1 fm Page 1 Tuesday October 11 2005 10 32 AM...

Reviews: