Daikin FHQ71BUV1B x 2 Operation Manual Download Page 8

4

English

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.

COOLING

HEATING

For Australia model Only
COOLING

HEATING

D B: Dry bulb temperature (

°

C)

WB: Wet bulb temperature (

°

C)

The setting temperature range of the remote con-
troller is 16°C to 32°C.

3. OPERATION RANGE

OUTDOOR UNIT

INDOOR

OUTDOOR 
TEMPERA-
TURE

TEMPERA-
TURE

HUMID-
ITY

RZQ71 · 100 ·

125 · 140

DB 18 to 37

80% or 
below

DB – 15 to 50

WB 12 to 28

RQ 71 · 100 ·

125

DB 18 to 37

80% or 
below

DB – 5 to 46

WB 12 to 28

RR 71 · 100 ·

125

DB 18 to 37

80% or 
below

DB – 15 to 46

WB 12 to 28

OUTDOOR UNIT

INDOOR
TEMPERATURE

OUTDOOR 
TEMPERATURE

RZQ71 · 100 ·

125 · 140

DB

10 to 27

DB

–19.5 to 21

WB

– 20 to 15.5

RQ 71 · 100 ·

125

DB

10 to 27

DB

– 9 to 21

WB

– 10 to 15

OUTDOOR UNIT

INDOOR

OUTDOOR 
TEMPERA-
TURE

TEMPERA-
TURE

HUMID-
ITY

RZQ71

DB 20 to 37

80% or 
below

DB – 5 to 46

WB 14 to 28

OUTDOOR UNIT

INDOOR
TEMPERATURE

OUTDOOR 
TEMPERATURE

RZQ71

DB

10 to 27

DB

– 14 to 21

WB

– 15 to 15.5

Regarding places for installation

• Is the air conditioner installed at a well-venti-

lated place where there are no obstacles 
around?

• Do not use the air conditioner in the following 

places.

a.Filled with much mineral oil such as cutting oil
b.Where there is much salt such as a beach area
c.Where sulfured gas exists such as a hot-spring 

resort

d.Where there are considerable voltage fluctua-

tions such as a factory or plant

e.Vehicles and vessels

 

f

 

.Where there is much spray of oil and vapor such 

as a cookery, etc.

g.Where there are machines generating electro-

magnetic waves

h.Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer.

Regarding wiring

• All wiring must be performed by an authorized 

electrician.

To do wiring, ask your dealer. Never do it by your-
self.

• Make sure that a separate power supply cir-

cuit is provided for this air conditioner and 
that all electrical work is carried out by quali-
fied personnel according to local laws and 
regulations.

Pay attention to running noises, too

• Are the following places selected?

a.A place that can sufficiently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b.A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises.

• Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

• If abnormal noises occur in use, stop the 

operation of the air conditioner, and then con-
sult your dealer or our service station.

4. INSTALLATION SITE

01_EN_3PN07753-4E.fm  Page 4  Wednesday, February 28, 2007  9:21 AM

Summary of Contents for FHQ71BUV1B x 2

Page 1: ...SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling suspension type FHQ71BUV1B FHQ71BVV1B FHQ100BUV1B FHQ100BVV1B FHQ125BUV1B FHQ125BVV1B English Deutsch Fran ais Espa ol Italiano Nederlands Portu...

Page 2: ...l acondicionador de aire Dicho manual le indicar c mo utilizar adec uadamente la m quina y le ayudar en caso de aver a Despu s de leer el manual cons rvelo para consultas futuras Funcionamiento consul...

Page 3: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 4: ...1 b d e k j a k i h f f c e e d d g...

Page 5: ...manual that came with the remote controller you are using If your installation has a customized control system ask your Daikin dealer for the operation that corre sponds to your system Heat pump type...

Page 6: ...your health may be ruined When the air conditioner is in abnormal con ditions smell of something burning etc unplug the power cord from the outlet and contact the dealer where you purchased the air c...

Page 7: ...nit or avoid placing any object on it Falling or tumbling may result in injury Do not expose animals and plants directly to the wind from the air conditioner Adverse influence to animals and plants ma...

Page 8: ...with much mineral oil such as cutting oil b Where there is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions...

Page 9: ...ore it takes some time until the entire room is warmed up after the start of operation An indoor fan runs to discharge a gentle wind automatically until the temperature inside the air conditioner reac...

Page 10: ...upply switch when it is not used for long periods of time When the main power switch is turned on some watts of electricity is being used even if the system is not operating Turn off the main power su...

Page 11: ...thinner polishing powder liquid insecticide It may cause discolor ing or warping Do not let the indoor unit get wet It may cause an electric shock or a fire Do not use water or air of 50 C or higher f...

Page 12: ...OF THE AIR CONDITIONER The outdoor unit is stopped This is because the room temperature has reached the set temperature The indoor unit switches to fan operation II WHEN IS DISPLAYED AND OPER ATION IS...

Page 13: ...f operation Expansion and contraction of plastic parts caused by temperature change makes this noise VII DUST FROM THE UNITS Dust may blow out from the unit after starting operation from long resting...

Page 14: ...MAINTENANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outlet of the indoor or the out door unit is blocked with obstacles Remove the obstacle and make it we...

Page 15: ...EM03A093D 0704 HT 3PN07753 4E...