English
1
CONTENTS
ILLUSTRATIONS................................................. [1]
1. WHAT TO DO BEFORE OPERATION .......... 1
2. SAFETY CONSIDERATIONS........................ 2
3. OPERATION RANGE .................................... 4
4. INSTALLATION SITE..................................... 4
5. OPERATION PROCEDURE .......................... 5
6. OPTIMUM OPERATION ................................ 6
7. MAINTENANCE
(FOR SERVICE PERSONNEL) ..................... 6
8. NOT MALFUNCTION OF THE AIR
CONDITIONER .............................................. 8
9. TROUBLE SHOOTING .................................. 9
Important information regarding the refrig-
erant used
This product contains fluorinated greenhouse gases
covered by the Kyoto Protocol.
Refrigerant type:R410A
GWP
(1)
value:
1975
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be
required depending on European or local legisla-
tion. Please contact your local dealer for more infor-
mation.
The following systems are available, so check which
system is in place with your dealer before use.
1. WHAT TO DO BEFORE OPERA-
TION
Indoor unit
Unit with
remote
controller
Unit without remote
controller
(When used as
simultaneous
operation system)
Outdoor unit
• Pair system or Simultaneous operation
system
NOTE
•
Read the operation manual that came with the
remote controller you are using.
If your installation has a customized control system,
ask your Daikin dealer for the operation that corre-
sponds to your system.
•
Heat pump type
This system provides cooling, heating, automatic,
program dry, and fan operation modes.
•
Cooling only type
This system provides cooling, program dry, and
fan operation modes.
PRECAUTIONS FOR GROUP CONTROL
SYSTEM OR TWO REMOTE CONTROLLER
CONTROL SYSTEM
This system provides two other control systems
beside individual control (one remote controller con-
trols one indoor unit) system. Confirm the following if
your unit is of the following control system type.
• Group control system
One remote controller controls up to 16 indoor units.
All indoor units are equally set.
• Two remote controllers control system
Two remote controllers control one indoor unit (In
case of group control system, one group of indoor
units)
The unit is individually operated.
NOTE
•
Contact your Daikin dealer in case of changing
the combination or setting of group control and
two remote controllers control system.
• Multi system
Indoor unit
Indoor unit
Unit with
remote
controller
Unit with
remote
controller
Outdoor unit
01_EN_3PN07753-4E.fm Page 1 Wednesday, February 28, 2007 9:21 AM