background image

9

• Press the TIMER ON/OFF button once again to cancel pro-

gramming. The display vanishes.

Observe the following precautions to ensure the system oper-
ates.

• Adjust the room temperature properly for a comfortable envi-

ronment. Avoid excessive heating or cooling.

• Prevent direct sunlight from entering a room during cooling 

operation by using curtains or blinds.

• Ventilate the room regularly.

Using the unit for long periods of time requires attentive ven-
tilation of the room.

• Keep doors and windows closed. If the doors and windows 

remain open, room air will flow out and cause to decrease the 
effect of cooling and heating.

• Do not place other heaters directly below the indoor unit.

They may deform due to the heat.

• Never place objects near the air inlet and the air outlet of the 

unit. It may cause deterioration in the effect or stop in the 
operation.

• Turn off the main power supply switch when it is not used for 

long periods of time. When the main power switch is turned 
on, some watts of electricity is being used even if the system 
is not operating. Turn off the main power supply switch for 
saving energy. When reoperating, turn on the main power 
supply switch 6 hours before operation for smooth running 
(Refer to “MAINTENANCE”).

• When the display shows “

 

(TIME TO CLEAN AIR FIL-

TER), ask a qualified service person to clean the filters 
(Refer to “MAINTENANCE”).

ONLY A QUALIFIED SERVICE PERSON IS ALLOWED 
TO PERFORM MAINTENANCE

IMPORTANT!

• BEFORE OBTAINING ACCESS TO TERMINAL DEVICES, 

ALL POWER SUPPLY CIRCUITS MUST BE INTER-
RUPTED

• To clean the air conditioner, be sure to stop operation, and 

turn the power switch off. Otherwise, an electric shock and 
injury may result.

• Do not wash the air conditioner with water.

Doing so may result in an electric shock.

• Be careful with a scaffold or staging.

Caution must be exercised because of work at a high place.

HOW TO CLEAN THE AIR FILTER

Clean the air filter when the display shows “

” (TIME TO 

CLEAN AIR FILTER).
Increase the frequency of cleaning if the unit is installed in a 
room where the air is extremely contaminated.
If the dirt becomes impossible to clean, change the air filter
(Contact your dealer when you exchange air filter.).

1. Open the suction grille.

Slide knobs (×2) simultaneously as shown and then pull 
them downward. (Do the same procedure for closing.)

(Refer to Fig. 5)

2. Remove the air filters

Push the 2 tabs up, and remove slowly lower the air filter.

(Refer to Fig. 6)

3. Clean the air filter.

Use vacuum cleaner 

A)

 or wash the air filter with water

 B).

A)

Using a vacuum cleaner

(Do not use air of 120°F or higher.)

B)

Washing with water

When the air filter is very dirty, use 
soft brush and neutral detergent.
(Do not use water of 120°F or higher.)

Remove water and dry in the shade.

NOTE

• Do not wash the air conditioner with hot water of more than 

120°F, as doing so may result in discoloration and/or defor-
mation.

• Do not expose it to fire, as doing so may result in burning.

4. Fix the air filter

Set the tab of the air filter to the hook of the suction grille, 
and fix the air filter. (By the method opposite to removing.)

5. Shut the suction grille by the method opposite to opening.
6. Press the FILTER SIGN RESET BUTTON on the remote 

controller.

The display “

” (TIME TO CLEAN AIR FILTER) vanishes.

HOW TO CLEAN AIR OUTLET AND OUTSIDE PANELS

• Clean with soft cloth.
• When it is difficult to remove stains, use water or neutral 

detergent.

7.

OPTIMUM OPERATION

8.

MAINTENANCE
(FOR SERVICE PERSONNEL)

Knob

Fig. 5

Tab

Hook

Fig. 6

Summary of Contents for FHQ24MVJU

Page 1: ...FHQ30MVJU FHQ36MVJU FHQ42MVJU OPERATION MANUAL SPLIT SYSTEM Air Conditioners Read these instructions carefully before installation Keep this manual in a handy place for future reference This manual s...

Page 2: ...3 TEST F hr hr TEST NOT AVAILABLE L H 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 Fig 1 b d e k j a i h f f c e e d d g Fig 3 F hr H Fig 4 Fig 2...

Page 3: ...ng caution and note symbols DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situ ation which if...

Page 4: ...could result in a shock hazard or fire if a spill occurs Do not put a finger or other objects into the air inlet or air outlet The fan is rotating at high speed and will cause injury The heat exchang...

Page 5: ...Is a snow protection measure taken For details consult your dealer Regarding wiring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make...

Page 6: ...uns to discharge a gentle wind automatically until the temperature inside the air conditioner reaches a cer tain level At this time the remote controller displays Leave it as it stands and wait for a...

Page 7: ...in the following two ways Programming the stop time The system stops operating after the set time has elapsed Programming the start time The system starts operating after the set time has elapsed The...

Page 8: ...an electric shock and injury may result Do not wash the air conditioner with water Doing so may result in an electric shock Be careful with a scaffold or staging Caution must be exercised because of...

Page 9: ...n some watts of electricity is being used even if the system is not operating Turn off the main power supply switch for saving energy The display on the remote controller will vanish when the main pow...

Page 10: ...lug the power cord from the outlet and contact your dealer Continued operation under such circumstances may result in a failure electric shock and fire If a safety device such as a fuse a breaker or a...

Page 11: ...unlight enters the room when cooling Use curtains or blinds When there are too many inhabitants in the room when cooling Cooling effect decreases if heat gain of the room is too large If the heat sour...

Page 12: ...0510 FS 3PN05140 9W EM04A050A...