background image

6

• Never pull or twist the electric wire of the remote controller.

It may cause the unit to malfunction.

• Do not place appliances which produce open fire in 

places exposed to the air flow from the unit or under the 
indoor unit. It may cause incomplete combustion or 
deformation of the unit due to the heat.

• Arrange the drain pipe to ensure smooth drainage. 

Incomplete drainage may cause wetting of the building, 
furniture etc.

• Do not place the controller exposed to direct sunlight.

The LCD display may get discolored, failing to display the data.

• Do not wipe the controller operation panel with benzine, 

thinner, chemical dustcloth, etc.

The panel may get discolored or the coating peeled off. If it is 
heavily dirty, soak a cloth in water-diluted neutral detergent, 
squeeze it well and wipe the panel clean. And wipe it with 
another dry cloth.

• Dismantling of the unit, treatment of the refrigerant, oil 

and eventual other parts, should be done in accordance 
with the relevant local and national regulations.

• Do not dry the filter by exposing it to direct sunlight or 

warming it using fire, etc. Doing so can result in the 
deformation of the filter.

If the temperature or the humidity is beyond the following condi-
tions, safety devices may work and the air conditioner may not 

operate, or sometimes, water may drop from the indoor unit.

D

 

B : Dry bulb temperature (

°

F)

WB : Wet bulb temperature (

°

F)

The setting temperature range of the remote controller is 60°F 
to 90°F.

Regarding places for installation

• Is the air conditioner installed at a well-ventilated place 

where there are no obstacles around?

• Do not use the air conditioner in the following places.

a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring resort
d. Where there are considerable voltage fluctuations such as 

a factory or plant

e. Vehicles and vessels
 f. Where there is much spray of oil and vapor such as a 

cookery, etc.

g. Where there are machines generating electromagnetic 

waves

h. Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer.

Regarding wiring

• All wiring must be performed by an authorized electrician.

To do wiring, ask your dealer. Never do it by yourself.

• Make sure that a separate power supply circuit is pro-

vided for this air conditioner and that all electrical work 
is carried out by qualified personnel according to local 
laws and regulations.

Pay attention to running noises, too

• Are the following places selected?

a. A place that can sufficiently withstand the weight of the air 

conditioner with less running noises and vibrations.

b. A place where the hot wind discharged from the air outlet 

of the outdoor unit and the running noises.

• Are you sure that there are no obstacles near the air out-

let of the outdoor unit?

Such obstacles may result in declined performance and 
increased running noises.

• If abnormal noises occur in use, consult your dealer.

Regarding drainage of drain pipe

• Is the drain pipe executed to perform complete drainage?

If proper drainage is not carried out from the outdoor drain 
pipes during air-conditioning operation, chances are that 
dust and dirt are clogged in the pipe. This may result in a 
water leakage from the indoor unit. Under such circum-
stances, stop the operation of the air conditioner, and then 
consult your dealer or our service station.

 Refer to Fig. 1 on page 3 

The illustrations in this operation manual correspond to the 
remote control format BRC1C type.

3.

OPERATION RANGE

OUTDOOR UNIT

OPERATION

TEMPERATURE (°F)

OUTDOOR

INDOOR

RZQ24 · 30 · 36 · 

42MVJU

COOLING

23 to 115 (DB)

57 to 77 (WB)

HEATING

5 to 64.5 (WB) 59 to 80.5 (DB)

4.

INSTALLATION SITE

5.

NAME AND FUNCTION OF EACH SWITCH 
AND DISPLAY ON THE REMOTE CON-
TROLLER 

1

ON/OFF BUTTON

Press the button and the system will start. Press the 
button again and the system will stop.

2

OPERATION LAMP (RED)

The lamp lights up during operation.

3

DISPLAY “

(UNDER CENTRALIZED CONTROL)

When this display shows, the system is UNDER CEN-
TRALIZED CONTROL.

4

DISPLAY  “

”  “

”  “

”  “

”  “

(OPERATION MODE)

This display shows the current OPERATION MODE.

5

DISPLAY “

TEST

(INSPECTION/TEST OPERATION)

When the INSPECTION/TEST OPERATION BUTTON 
is pressed, the display shows the system mode is in.

6

DISPLAY “

” (PROGRAMMED TIME)

This display shows the PROGRAMMED TIME of the 
system start or stop.

hr

hr

Summary of Contents for FHQ24MVJU

Page 1: ...FHQ30MVJU FHQ36MVJU FHQ42MVJU OPERATION MANUAL SPLIT SYSTEM Air Conditioners Read these instructions carefully before installation Keep this manual in a handy place for future reference This manual s...

Page 2: ...3 TEST F hr hr TEST NOT AVAILABLE L H 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 Fig 1 b d e k j a i h f f c e e d d g Fig 3 F hr H Fig 4 Fig 2...

Page 3: ...ng caution and note symbols DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situ ation which if...

Page 4: ...could result in a shock hazard or fire if a spill occurs Do not put a finger or other objects into the air inlet or air outlet The fan is rotating at high speed and will cause injury The heat exchang...

Page 5: ...Is a snow protection measure taken For details consult your dealer Regarding wiring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make...

Page 6: ...uns to discharge a gentle wind automatically until the temperature inside the air conditioner reaches a cer tain level At this time the remote controller displays Leave it as it stands and wait for a...

Page 7: ...in the following two ways Programming the stop time The system stops operating after the set time has elapsed Programming the start time The system starts operating after the set time has elapsed The...

Page 8: ...an electric shock and injury may result Do not wash the air conditioner with water Doing so may result in an electric shock Be careful with a scaffold or staging Caution must be exercised because of...

Page 9: ...n some watts of electricity is being used even if the system is not operating Turn off the main power supply switch for saving energy The display on the remote controller will vanish when the main pow...

Page 10: ...lug the power cord from the outlet and contact your dealer Continued operation under such circumstances may result in a failure electric shock and fire If a safety device such as a fuse a breaker or a...

Page 11: ...unlight enters the room when cooling Use curtains or blinds When there are too many inhabitants in the room when cooling Cooling effect decreases if heat gain of the room is too large If the heat sour...

Page 12: ...0510 FS 3PN05140 9W EM04A050A...

Reviews: