background image

FH(Y)B+C(P) + FDY(P) + FBQ + FCQ + FDQ
Split system air conditioners
4PW10622-1C

Operation manual

4

M

AINTENANCE

How to clean the air filter

Clean the air filter when the display shows "

" (TIME TO CLEAN

AIR FILTER).

Increase the frequency of cleaning if the unit is installed in a room
where the air is extremely contaminated.

(As a yardstick for yourself, consider cleaning the filter once half a
year.)

If the dirt becomes impossible to clean, change the air filter. (Air filter
for exchange is optional.)

For FHYC and FCQ-units 

(See figure 6)

1

Open the suction grille.

Push both knobs simultaneously and carefully lower the grille.
(Identical procedure for closing.)

2

Remove the air filters.

Pull the air filter clips toward you, and detach the filter.

3

Clean the air filter. (Refer to 

figure 3

 

 air flow direction over

filter.)

Use vacuum cleaner or wash the air filter with water.
When the air filter is very dirty, use soft brush and neutral
detergent.

4

Remove water and dry in the shade.

5

Fix the air filter.

Attach the air filter to the suction grille by hanging it to the
projected portion above the suction grille.
Press the bottom of the air filter against the projections on the
bottom of the grille to snap the air filter into its place.

6

Shut the air inlet grille.

Refer to item 1 

"Open the suction grille." on page 4

.

7

After turning on the power, press the FILTER SIGN RESET
button.

The "TIME TO CLEAN AIR FILTER" display vanishes.

For FHYB and FBQ-units 

(See figure 7)

1

Open the suction grille. (Only for bottom suction.)

Slide both knobs simultaneously as shown and then pull them
downward.
If chains are present, unhook the chains.

2

Remove the air filters.

Remove the air filters by pulling its cloth upward (rear suction) or
backward (bottom suction).

3

Clean the air filter. (Refer to 

figure 3

 

 air flow direction over

filter.)

Use vacuum cleaner or wash the air filter with water.
When the air filter is very dirty, use soft brush and neutral
detergent.
Remove water and dry in the shade.

4

Fix the air filter.

Align the two hanger brackets and push the two clips in their
place (pull the cloth if necessary, rear, bottom suction).
Confirm that the four hangers are fixed.

5

Shut the air inlet grille. (Only for bottom suction.)

6

After turning on the power, press FILTER SIGN RESET button.

The "TIME TO CLEAN AIR FILTER" display is turned off.

For FDY and FDQ-units 

(See figure 5)

1

Remove the screws from the bottom of the filter frame and
remove the filter frame downwards.

2

Clean the air filter. (Refer to 

figure 3

 

 air flow direction over

filter.)

Use compressed air for blowing dust particles of the filter. When
the air filter is very dirty, use soft brush and neutral detergent or
wash with hot (30-40°C) water if needed. Do not rub or wring.

3

Remove water and dry in the shade.

4

Fix the air filter. Put the air filter frame back in its position and fix
firmly with the screws.

Caution

Only a qualified service person is allowed to perform
maintenance.

Before obtaining access to terminal devices, all power
supply circuits must be interrupted.

Do not use water or air of 50°C or higher for cleaning
air filters and outside panels.

When cleaning the heat exchanger, be sure to remove
the switchbox, fan motor, auxiliary electric heater and
drain pump. Water or detergent may deteriorate the
insulation of electronic components and result in burn-
out of these components.

Caution for drain socket

Do not remove the drain pipe plug. Water might leak out.

The drain outlet is only used to discharge water if the drain
pump is not used or before maintenance. Gently put in and
out the drain plug. Excessive force may deform the drain
socket of the drain pan.

Pulling out the plug 

Do not wiggle the plug up and down

Pushing in the plug

Set the plug and push it by using a Philips screwdriver

1

1

Drain plug

1

2

1

Drain plug

2

Philips screwdriver

Summary of Contents for FHC45B7V1

Page 1: ...Q35B7V1 FBQ50B7V1 FBQ60B7V1 FBQ71B7V3B FBQ100B7V3B FBQ125B7V3B FHB35GZ7V1 FHB45GZ7V1 FHYB35GZ7V1 FHYB45GZ7V1 FHYBP35B7V1 FHYBP45B7V1 FHYBP60B7V1 FHYBP71B7V1 FHYBP100B7V1 FHYBP125B7V1 FHC35BZ7V1 FHC45B...

Page 2: ...250 12 25 21 32 14 23 21 32 14 23 18 35 14 28 15 27 15 24 10 30 10 30 10 27 RXS35 50 60 4MXS68 80 RZQ71 100 125 RZQ71 100 125 R P 200 250 R P 71 100 125 R35 45 60 RS50 60 RKS35 50 60 RXS35 50 60 3MKS5...

Page 3: ...6 7 6 7...

Page 4: ...E These units can be controlled by a remote controller Refer to the manual of the remote controller for more information A Pair system or simultaneous operation system B Multi system 1 Unit with remot...

Page 5: ...play shows EXTERNAL CONTROL ICON and it flashes for a few seconds after pressing an operation button This is because the system is controlled or disabled by another controller with a higher priority W...

Page 6: ...alfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person If a safety device such as a fuse a breaker or an earth leakag...

Page 7: ...r Use vacuum cleaner or wash the air filter with water When the air filter is very dirty use soft brush and neutral detergent Remove water and dry in the shade 4 Fix the air filter Align the two hange...

Page 8: ...outlet are not blocked Remove any obstacle Check if the earth is connected Clean the air filter and outside panels After cleaning the air filter make sure to attach it Turn on the main power supply s...

Page 9: ...NOTES NOTES...

Page 10: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN10622 1C...