Unique design in the market that integrates fully flat into the ceiling

Fully flat integration in standard architectural ceiling tiles, leaving only 
8mm

Remarkable blend of iconic design and engineering excellence with 
an elegant finish in white or a combination of silver and white

Two optional intelligent sensors improve energy efficiency and 
comfort. The presence sensor adjusts the set point  if no one is 
detected in the room.  It also automatically directs air flow away from 
any person to avoid draught. The infrared floor sensor detects the 
average floor temperature and ensures even temperature distribution 
between ceiling and floor to prevent cold feet.

Reduced energy consumption thanks to specially developed small 
tube heat exchanger, DC fan motor and drain pump

Fresh air intake integrated in the same system thus reducing 
installation cost as no additional ventilation is required

Standard drain pump with 850mm lift increases flexibility and 
installation speed

No optional adapter needed for DIII-connection, link your unit into the 
wider building management system.

Inverter

Presence & 
floor sensor

Home leave 

operation

Fan only

Draught 

prevention

Auto cooling-

heating 

changeover

Whisper quiet

Ceiling soiling 

prevention

Individual flap 

control

Vertical auto 

swing

Fan speed 

steps

Dry programme

Air filter

Weekly timer Infrared remote 

control

Wired remote 

control

Auto-restart

Self diagnosis

Drain pump kit

Twin/triple/

double twin 

application

Multi model 

application

VRV for 

residential 

application

Summary of Contents for FFQ25C

Page 1: ...Air Conditioning Technical Data Fully flat cassette EEDEN15 100 FFQ C...

Page 2: ......

Page 3: ...fety device settings 5 4 Options 6 5 Dimensional drawings 7 6 Centre of gravity 9 7 Piping diagrams 10 8 Wiring diagrams 11 Wiring Diagrams Single Phase 11 9 External connection diagrams 12 10 Sound d...

Page 4: ...re distribution between ceiling and floor to prevent cold feet Reduced energy consumption thanks to specially developed small tube heat exchanger DC fan motor and drain pump Fresh air intake integrate...

Page 5: ...Empty tubeplate hole Quantity 0 Fin Type Cross fin coil multi slit fins and hi XA tubes Air filter Type Resin net with mold resistance Fan Type Turbo fan Quantity 1 Air flow rate Cooling High m min 9...

Page 6: ...Quantity 8 Standard Accessories Screws Quantity 4 Standard Accessories Paper pattern for installation Quantity 1 Standard Accessories Insulation for fitting Quantity 2 Standard Accessories Sealing pad...

Page 7: ...3 3 Split Sky Air FFQ C 5 Indoor Unit FFQ C 3 Safety device settings 3 1 Safety Device Settings...

Page 8: ...HG RQ RII FRQWURO Yes Yes Yes DCS301B51 Schedule timer Yes Yes Yes DST301B51 Wiring adapter for electrical appendices Yes Yes Yes KRP1B57 Wiring adapter for electrical appendices Yes Yes Yes Wiring ad...

Page 9: ...3 5 Split Sky Air FFQ C 7 Indoor Unit FFQ C 5 Dimensional drawings 5 1 Dimensional Drawings...

Page 10: ...Indoor Unit FFQ C 5 Split Sky Air FFQ C 8 5 Dimensional drawings 5 1 Dimensional Drawings...

Page 11: ...3 6 Split Sky Air FFQ C 9 Indoor Unit FFQ C 6 Centre of gravity 6 1 Centre of Gravity...

Page 12: ...Indoor Unit FFQ C 7 Split Sky Air FFQ C 10 7 Piping diagrams 7 1 Piping Diagrams...

Page 13: ...3 8 Split Sky Air FFQ C 11 Indoor Unit FFQ C 8 Wiring diagrams 8 1 Wiring Diagrams Single Phase...

Page 14: ...Indoor Unit FFQ C 9 Split Sky Air FFQ C 12 9 External connection diagrams 9 1 External Connection Diagrams...

Page 15: ...3 10 Split Sky Air FFQ C 13 Indoor Unit FFQ C 10 Sound data 10 1 Sound Pressure Spectrum Cooling...

Page 16: ...Indoor Unit FFQ C 10 Split Sky Air FFQ C 14 10 Sound data 10 2 Sound Pressure Spectrum Heating...

Page 17: ...3 11 Split Sky Air FFQ C 15 Indoor Unit FFQ C 11 Air flow patterns 11 1 Air Flow Pattern Cooling...

Page 18: ...Indoor Unit FFQ C 11 Split Sky Air FFQ C 16 11 Air flow patterns 11 1 Air Flow Pattern Cooling...

Page 19: ...3 11 Split Sky Air FFQ C 17 Indoor Unit FFQ C 11 Air flow patterns 11 1 Air Flow Pattern Cooling...

Page 20: ...Indoor Unit FFQ C 11 Split Sky Air FFQ C 18 11 Air flow patterns 11 1 Air Flow Pattern Cooling...

Page 21: ...3 11 Split Sky Air FFQ C 19 Indoor Unit FFQ C 11 Air flow patterns 11 2 Air Flow Pattern Heating...

Page 22: ...Indoor Unit FFQ C 11 Split Sky Air FFQ C 20 11 Air flow patterns 11 2 Air Flow Pattern Heating...

Page 23: ...3 11 Split Sky Air FFQ C 21 Indoor Unit FFQ C 11 Air flow patterns 11 2 Air Flow Pattern Heating...

Page 24: ...Indoor Unit FFQ C 11 Split Sky Air FFQ C 22 11 Air flow patterns 11 2 Air Flow Pattern Heating...

Page 25: ...in Europe N V has compiled the content of this leaflet to the best of its knowledge No express or implied warranty is given for the completeness accuracy re liability or fitness for particular purpose...

Reviews: