![background image](http://html1.mh-extra.com/html/daikin/ffq09q2vjuffq12q2vjuffq15q2vjuffq18q2vjurx09qmvjurx12qmvjurx15qmvjurx18qmvju/ffq09q2vjuffq12q2vjuffq15q2vjuffq18q2vjurx09qmvjurx12qmvjurx15qmvjurx18qmvju_service-manual_2460415013.webp)
SiUS091628EA
Functions
List of Functions
2
1. Functions
Category
Functions
FFQ
09
/12/
15/
18Q2V
JU
RX
09/
12/
15/
18QM
V
J
U
wi
th B
Y
FQ60B
3W1
FFQ
09
/12/
15/
18Q2V
JU
RX
09/
12/
15/
18QM
V
J
U
wi
th B
Y
FQ60C2W1W(S
)
Category
Functions
FFQ
09
/12/
15/
18Q2V
JU
RX
09/
12/
15/
18QM
V
J
U
wi
th B
Y
FQ60B
3W1
FFQ
09
/12/
15/
18Q2V
JU
RX
09/
12/
15/
18QM
V
J
U
wi
th B
Y
FQ60C2W1W(S
)
Basic
Functions
Inverter (with inverter power control)
z
z
Health &
Cleanliness
Auto cleaning filter
—
—
Operation limit for cooling
Refer to
P. 133
Air-purifying filter
—
—
Operation limit for heating
Titanium apatite deodorizing filter
(option)
—
—
PAM control
—
—
Standby electricity saving
—
—
Longlife filter
z
z
Compressor
Oval scroll compressor
—
—
Air filter
—
—
Swing compressor
z
z
Filter cleaning indicator
z
z
Rotary compressor
—
—
Wipe-clean flat panel
—
—
Reluctance DC motor
z
z
Washable grille
z
z
Comfortable
Airflow
Power-airflow flap (horizontal blade)
—
—
MOLD PROOF operation
—
—
Power-airflow dual flaps
(horizontal blade)
—
—
Good-sleep cooling operation
—
—
Timer
Schedule TIMER operation
z
★
1
z
★
1
Power-airflow diffuser
—
—
72-hour ON/OFF TIMER
z
★
2
z
★
2
Wide-angle louvers (vertical blades)
—
—
NIGHT SET mode
—
—
Auto-swing (up and down)
z
z
Off Timer (power off forget prevention)
z
★
1
z
★
1
Auto-swing (right and left)
—
—
Worry Free
(Reliability &
Durability)
Auto-restart (after power failure)
z
z
Individual flap control
—
z
★
1
Self-diagnosis (R/C, LED)
z
z
3-D airflow
—
—
Wiring error check function
—
—
COMFORT AIRFLOW operation
—
—
Anti-corrosion treatment of outdoor heat
exchanger
—
—
Comfort
Control
Auto fan speed
z
★
1
z
★
1
Indoor unit quiet operation
—
—
Flexibility
Multi-split/split type compatible indoor
unit
z
z
NIGHT QUIET mode (automatic)
—
—
OUTDOOR UNIT QUIET operation
(manual)
—
—
H/P, C/O compatible indoor unit
—
—
Flexible power supply correspondence
—
—
Presence and floor sensor (option)
—
z
★
1
Chargeless
32.8 ft
(10 m)
32.8 ft
(10 m)
Hot-start function
z
z
Draft prevention with sensor
z
z
Either side drain (right or left)
—
—
Automatic defrosting
z
z
Power selection
—
—
Operation
Automatic operation
z
z
Low outdoor temperature cooling
operation (-20°C) (-4°F)
z
★
3
z
★
3
Program dry function
z
z
Fan only
z
z
°F/°C changeover R/C temperature
display (factory setting: °F)
z
★
1
z
★
1
Setback function
z
★
1
z
★
1
Lifestyle
Convenience
POWERFUL operation (non-inverter)
—
—
Remote
Control
Remote control adaptor
(normal open pulse contact) (option)
—
—
POWERFUL operation (inverter)
—
—
Priority-room setting
—
—
Remote control adaptor
(normal open contact) (option)
—
—
COOL/HEAT mode lock
—
—
HOME LEAVE operation
—
—
DIII-NET compatible (adaptor) (option)
—
—
ECONO operation
—
—
Remote
Controller
Wireless (option)
z
z
Indoor unit
ON/OFF
button
—
—
Wired (option)
z
z
Signal receiving sign
z
★
2
★
4
z
★
2
★
4
R/C with back light
z
★
1
z
★
1
Note:
z
: Available
— : Not available
★
1: With wired remote controller
★
2: With wireless remote controller
★
3: With air direction adjustment grille (option)
★
4: Receiving sound only
Summary of Contents for FFQ09Q2VJUFFQ12Q2VJUFFQ15Q2VJUFFQ18Q2VJURX09QMVJURX12QMVJURX15QMVJURX18QMVJU
Page 12: ...SiUS091628EA 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 14: ...SiUS091628EA 3 Specifications Part 2 Specifications 1 Specifications 4...
Page 120: ...Check SiUS091628EA 109 Service Diagnosis 15 18 class R20701 1 2 3 4 Multimeter...