Ducted Air Conditioners

Operation Manual

NOISE FROM THE AIR CONDITIONER

• A continuous low “shuh” sound is heard when the system is in 

COOLING or DEFROST OPERATION. 

This is the sound of refrigerant gas flowing through both indoor and 

outdoor units.  

• A”shuh” sound which is heard at the start or immediately after 

the stop of operation or which is heard at the start or immediately 

after the stop of DEFROST OPERATION. 

This is the noise of refrigerant stopping or changing direction.

DUST FROM THE AIR CONDITIONER

• Dust may blow out from the unit when starting the air conditioner 

after a long resting time. 

Dust that has settled in the unit is blown out.

THE AIR CONDITIONER GIVES OFF ODOURS

• The unit absorbs the smell of rooms, furniture, cigarettes, etc., and 

then emits them.

THE LIQUID CRYSTAL OF THE REMOTE 

CONTROLLER SHOWS

 “          “

• Happens immediately after the main power supply switch is 

turned on. 

Shows that the remote controller is in normal condition. Continues 

temporarily.

TROUBLE SHOOTING 

If one of the following malfunctions occurs, take the measures 

shown below and contact your Daikin dealer.

 

The system must be repaired by a qualified service person.

      WARNING

  When the air conditioner is in abnormal conditions (smell of     

  something burning, etc.), switch off the main switch, and contact 

  your dealer or DAIKIN 1300 36 24 38.

  Continued operation under such circumstances may result in a failure,   

  electric shock, or fire. 

• 

If a safety device such as a fuse, a circuit breaker, or an earth leakage 

circuit breaker frequently actuates, or the ON/OFF switch does not properly 
work. 

Measure: 

Turn off the main power switch. 

• 

Concerning the indoor unit, if water leaks from any location besides the 

drain pipe. 

Measure: 

Stop the operation. 

• 

If a 2 digit fault code appears in the LCD screen. 

Measure: 

Write down the fault code and then stop the operation. 

Measure: 

Notify your Daikin dealer and inform him/her of the display.

If the system does not operate properly and none of the above 

mentioned malfunctions is evident, investigate the system 

according to the following procedures. 

1.If the system does not operate at all. 

 

• 

Check if there is a power failure. Wait until power is restored. If a power 

failure occurs during operation, the system may automatically restart 
immediately after the power supply recovers.

• 

Check if the fuse has blown or circuit breaker has tripped. 

Please contact and notify qualified technicians to check. 

2

.If the system stops operating after operating for a while. 

 

• 

Check if the air inlet or outlet of outdoor or indoor unit is blocked by 

obstacles. Remove the obstacle and make it well-ventilated. 

• 

Check if the air filter is clogged. Clean the air filter(s). (Refer to 

MAINTENANCE).

3.The system operates but it does not sufficiently cool or heat.

 

 

• 

Check if the air inlet or outlet of the indoor or the outdoor unit is blocked 

with obstacles. Remove the obstacle and make it well-ventilated.  

• 

Check if the air filter is clogged. Clean the air filter(s). (Refer to 

MAINTENANCE).

• 

Check if the set temperature is within a comfortable range. 

• 

Check if the FAN SPEED CONTROL button is set to high. If you normally 

use low fan speed ensure the air filter is clean.  

• 

Check if the doors or the windows are open. Shut doors or windows to 

prevent wind from coming in.  

• 

Check if direct sunlight enters the room. (when cooling) Use curtains or 

blinds.  

• 

When there are too many occupants in the room. (when cooling) Cooling 

effect decreases if heat gain of the room is too large.  

• 

Check if the heat source of the room is excessive. (when cooling) Cooling 

effect decreases if heat gain of the room is too large.

 

Summary of Contents for FDYAN50AV1

Page 1: ...ries Air Conditioners MODELS Ceiling concealed duct type FDYAN50 60 71 85 100 125 140 160AV1 FDYA71 85 100 125 140 160AV1 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THIS MANUAL...

Page 2: ......

Page 3: ...the air conditioner Doing so may result in a fire To clean the air conditioner stop the operation and switch the power off at the main switch Otherwise an electric shock and injury may result Do not e...

Page 4: ...air conditioner without the return air filter s in place Operating the unit without the filter s will allow dust to enter the indoor unit and build up on the heat exchanger coil and fan motor This wil...

Page 5: ...ormation so if the temperature on the downstairs controller is increased from 21 to 23 degrees the upstairs controller will also indicate 23 degrees OPTIMUM OPERATION Observe the following precautions...

Page 6: ...pipe Measure Stop the operation If a 2 digit fault code appears in the LCD screen Measure Write down the fault code and then stop the operation Measure Notify your Daikin dealer and inform him her of...

Page 7: ...least 6 hours before operation WHAT TO DO WHEN STOPPING THE SYSTEM FOR A LONG PERIOD Turn on FAN OPERATION for a half day and dry the unit Refer to fan setting or fan speed button on pages 4 6 of the...

Page 8: ...368 300 Technical Support Spare Parts 200 Governor Macquarie Drive Warwick Farm NSW 2170 Phone 1300 362 438 Daikin New Zealand 25 Dalrymple Road Garbutt 4814 www daikin com au DAIKIN INDUSTRIES LTD He...

Reviews: