Note for Multi System

A multi system has one outdoor unit connected to multiple indoor units.

 

„

Selecting the operation mode

1. When the priority room setting is active but  

the set unit is not operating or when the priority 

room setting is inactive

When more than one indoor unit is operating, priority is given to the first 
unit that was turned on.
In this case, set the units that are turned on later to the same operation 
mode as the first unit.
Otherwise, they will enter the standby state, and when using the wired 
remote controller the centralized control icon “

” will blink; this does not 

indicate malfunction.

2. 

With the priority room setting active

Refer to 

“Priority room setting”

.

 

„

NIGHT QUIET mode (Available only for COOL operation)

NIGHT QUIET mode requires initial programming during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET mode reduces the operation noise of the outdoor unit during the night-time hours to prevent annoyance to neighbours.

• NIGHT QUIET mode is activated when the temperature drops 6°C or more below the highest temperature recorded that day.  

When the temperature difference between the current outdoor temperature and the maximum outdoor temperature becomes 
less than 4°C, this function will be cancelled.

• NIGHT QUIET mode slightly reduces the cooling efficiency of the unit.

 

„

Priority room setting

 

(U

navailable when connected with outdoor model MKM50VVMG or 

MKP50VVMG

)

The priority room setting requires initial programming during installation. Please consult your authorized dealer for assistance.
The room designated as the priority room takes priority in the following situations.

Operation mode priority

• As the operation mode of the priority room takes precedence, you can select a different operation mode from other rooms.

[Example]

• Room A is the priority room in this example. 

When COOL operation is selected in room A while operating the following modes in room B, C and D:

Operation mode in room B, C and D

Status of room B, C and D when the unit in room A is in COOL operation

COOL or DRY or FAN

The current operation mode is maintained.

Room A

Room B

Room C

Room D

Outdoor unit

NOTE

Notes on operation mode for a multi system

•  COOL, DRY and FAN operation may be used at the same time.

4

Multi Connection

Care

01_EN_3P620957-9A.indd   4

31-Jul-20   2:03:48 PM

Summary of Contents for FDMF50VVMG

Page 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FDMF50VVMG FDMF71VVMG FDMF60VVMG 00_CV_3P620957 9A indd 1 31 Jul 20 2 04 06 PM...

Page 2: ...00_CV_3P620957 9A indd 2 31 Jul 20 2 04 06 PM...

Page 3: ...your physical condition and health Do not place objects including rods your fingers etc in the air inlet or outlet Product damage or personal injury may result due to contact with the air conditioner...

Page 4: ...er as this may result in electric shock or fire Do not place water containers vases etc above the unit as this may result in electric shock or fire hazards if they should topple over Do not insert the...

Page 5: ...ame BRC1E63 Wireless type Model name BRC086A22 BRC086A2R1 Model name Model name plate Suction duct Field supply Suction grille Field supply Air filter Sold separately Wiring between the indoor and out...

Page 6: ...low the highest temperature recorded that day When the temperature difference between the current outdoor temperature and the maximum outdoor temperature becomes less than 4 C this function will be ca...

Page 7: ...essory Do not attach objects other than the genuine air filter e g kitchen paper to the air inlet Otherwise the performance of the air conditioner will be degraded and icing or water leakage may resul...

Page 8: ...to dry out the inside 1 Press the MODE selector button and select FAN operation 2 Press the ON OFF button and start operation 2 After operation stops turn off the circuit breaker for the room air cond...

Page 9: ...tion is stopped The outdoor fan continues rotating for another 30 seconds for system protection While the air conditioner is not in operation When the outdoor temperature is very high the outdoor fan...

Page 10: ...al sound is heard during operation The circuit breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burnin...

Page 11: ...01_EN_3P620957 9A indd 9 31 Jul 20 2 03 49 PM...

Page 12: ...M20N056 2008 HT The two dimensional bar code is a manufacturing code 3P620957 9A 00_CV_3P620957 9A indd 3 31 Jul 20 2 04 06 PM...

Reviews: