Service & Maintenance
Service & Maintenance
Disconnect from main supply before servicing the air conditioner.
The unit is designed to give long life operation with minimum maintenance required. However, it should be
regularly checked and the following items should be given due attention.
Components
Maintenance Procedure
Recommended Schedule
Air
fi
lter
(Indoor Unit)
1. Remove the ionizer
fi
lter before cleaning the
fi
lter.
2. Remove the dust adhering on the
fi
lter by using
a vacuum cleaner or wash using water less than
40°C with a neutral cleaning detergent.
3. Rinse and dry it before
fi
tting back the ionizer
fi
lter
and set it back to unit.
4. Note : Never use petrol thinner, benzene or any
other chemicals.
At least once a month.
Indoor unit
1. Clean away dirt or dust on grille or panel by wiping
with soft cloth soaked in lukewarm (or cool) water
or neutral detergent solution.
2. Note : Never user petrol, thinner, benzene or
other volatile chemicals, which may cause
plastic surface to deform.
At least once a month.
Condense Drain
Pan & Pipe
1. Check the cleanliness and clean it if necessary.
2. Check the condensate water
fl
ow.
Every 3 months.
Indoor Fan
Check if there is any abnormal noise.
If necessary.
Indoor/Outdoor
Coil
1. Check and remove the dirt between the
fi
ns.
2. Check and remove any obstacles which hinder air
fl
ow through the indoor or outdoor.
Every month.
Power Supply
1. Check the running current and voltage for indoor
and outdoor unit.
2. Check the electrical wiring and tighten the wire onto
the terminal block if necessary.
Every 2 months.
Every year.
Compressor
No maintenance needed if refrigerant circuit remains
sealed. However, check for refrigerant leak at joint and
fi
tting.
Every 6 months.
Compressor Oil
Oil is factory charged. Not necessary to add oil if circuit
remains sealed.
No maintenance required.
Fan Motor Oil
All motors are pre-lubricated and sealed at factory.
No maintenance required.
DAIKIN_R22 CC.indb 148
DAIKIN_R22 CC.indb 148
11/8/2012 11:40:27 AM
11/8/2012 11:40:27 AM
Summary of Contents for FDM10CXV1
Page 2: ......
Page 134: ...131 Wiring Diagrams Indoor Unit Model FDM15CXV1 FDB15CXV1 Outdoor Unit Model R15CXV1...
Page 135: ...132 Wiring Diagrams Indoor Unit Model FDM20 25CXV1 FDB20 25CXV1 Outdoor Unit Model R20 25CXV1...
Page 136: ...133 Wiring Diagrams Indoor Unit Model FDM28 30CXV1 FDB30CXV1 Outdoor Unit Model R28CXV1...
Page 137: ...134 Wiring Diagrams Indoor Unit Model FDM28 30CXV1 FDB30CXV1 Outdoor Unit Model R30DXV1...
Page 138: ...135 Wiring Diagrams Indoor Unit Model FDM28 30CXV1 FDB30CXV1 Outdoor Unit Model R30DXY1...
Page 139: ...136 Wiring Diagrams Indoor Unit Model FDM38 40CXV1 FDB40CXV1 Outdoor Unit Model R35 40DXV1...
Page 141: ...138 Wiring Diagrams Indoor Unit Model FDM60CXV1 FDB60CXV1 Outdoor Unit Model R61DXY1...
Page 143: ...140 Wiring Diagrams Indoor Unit Model FDYM15CXV1 FDYB15CXV1 Outdoor Unit Model RY15CXV1...
Page 145: ...142 Wiring Diagrams Indoor Unit Model FDYM28 30CXV1 FDYB30CXV1 Outdoor Unit Model RY28CXV1...
Page 146: ...143 Wiring Diagrams Indoor Unit Model FDYM28 30CXV1 FDYB30CXV1 Outdoor Unit Model RY30DXV1...
Page 147: ...144 Wiring Diagrams Indoor Unit Model FDYM28 30CXV1 FDYB30CXV1 Outdoor Unit Model RY30DXY1...
Page 148: ...145 Wiring Diagrams Indoor Unit Model FDYM38 40CXV1 FDYB40CXV1 Outdoor Unit Model RY35 40DXV1...
Page 150: ...147 Wiring Diagrams Indoor Unit Model FDYM60CXV1 FDYB60CXV1 Outdoor Unit Model RY61DXY1...
Page 159: ......