112
Performance Data
Model: FDYM40CXV1 - RY40DXY1
Heating Mode
ID DB
Outdoor WB
-9°C
-6°C
-5°C
6°C
12°C
15°C
18°C
TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW)
15°C
7.087
7.087
8.021
8.021
8.333
8.333
11.758 11.758 13.627 13.627 14.561 14.561 15.495 15.495
17°C
6.901
6.901
7.157
7.157
8.118
8.118
11.744 11.744 13.287 13.287 14.199 14.199 15.111 15.111
19°C
6.715
6.715
6.294
6.294
7.902
7.902
11.730 11.730 12.946 12.946 13.836 13.836 14.727 14.727
21°C
6.530
6.530
5.992
5.992
7.687
7.687
11.474 11.474 12.606 12.606 13.474 13.474 14.342 14.342
23°C
6.344
6.344
6.253
6.253
7.472
7.472
10.977 10.977 12.266 12.266 13.112 13.112 13.958 13.958
25°C
6.158
6.158
6.513
6.513
7.257
7.257
10.479 10.479 11.925 11.925 12.749 12.749 13.573 13.573
27°C
5.972
5.972
6.774
6.774
7.041
7.041
9.981
9.981
11.585 11.585 12.387 12.387 13.189 13.189
Frost Region
Remark:
AFR: Air
fl
ow rate (CFM)
EWB: Entering Wet Bulb Temp. (°C)
EDB: Entering Dry Bulb Temp. (°C)
TC: Total Cooling / Heating Capacity (kW)
SC: Sensible Cooling / Heating Capacity (kW)
PI: Power Input (kW)
Notes:
1. Ratings shown are net capacities.
2.
shows nominal capacities.
3. Direct interpolation is permissible. Do not extrapolate.
4. Unit is able to operate at ambient from 19°C to 46°C DB (cooling) / -9°C to 18°C WB (heating) without pressure trip.
DAIKIN_R22 CC.indb 112
DAIKIN_R22 CC.indb 112
11/8/2012 11:40:20 AM
11/8/2012 11:40:20 AM
Summary of Contents for FDM10CXV1
Page 2: ......
Page 134: ...131 Wiring Diagrams Indoor Unit Model FDM15CXV1 FDB15CXV1 Outdoor Unit Model R15CXV1...
Page 135: ...132 Wiring Diagrams Indoor Unit Model FDM20 25CXV1 FDB20 25CXV1 Outdoor Unit Model R20 25CXV1...
Page 136: ...133 Wiring Diagrams Indoor Unit Model FDM28 30CXV1 FDB30CXV1 Outdoor Unit Model R28CXV1...
Page 137: ...134 Wiring Diagrams Indoor Unit Model FDM28 30CXV1 FDB30CXV1 Outdoor Unit Model R30DXV1...
Page 138: ...135 Wiring Diagrams Indoor Unit Model FDM28 30CXV1 FDB30CXV1 Outdoor Unit Model R30DXY1...
Page 139: ...136 Wiring Diagrams Indoor Unit Model FDM38 40CXV1 FDB40CXV1 Outdoor Unit Model R35 40DXV1...
Page 141: ...138 Wiring Diagrams Indoor Unit Model FDM60CXV1 FDB60CXV1 Outdoor Unit Model R61DXY1...
Page 143: ...140 Wiring Diagrams Indoor Unit Model FDYM15CXV1 FDYB15CXV1 Outdoor Unit Model RY15CXV1...
Page 145: ...142 Wiring Diagrams Indoor Unit Model FDYM28 30CXV1 FDYB30CXV1 Outdoor Unit Model RY28CXV1...
Page 146: ...143 Wiring Diagrams Indoor Unit Model FDYM28 30CXV1 FDYB30CXV1 Outdoor Unit Model RY30DXV1...
Page 147: ...144 Wiring Diagrams Indoor Unit Model FDYM28 30CXV1 FDYB30CXV1 Outdoor Unit Model RY30DXY1...
Page 148: ...145 Wiring Diagrams Indoor Unit Model FDYM38 40CXV1 FDYB40CXV1 Outdoor Unit Model RY35 40DXV1...
Page 150: ...147 Wiring Diagrams Indoor Unit Model FDYM60CXV1 FDYB60CXV1 Outdoor Unit Model RY61DXY1...
Page 159: ......