background image

6

• Check the unit stand for damage on a contin-

uous basis. 

If left in a damaged condition the unit may fall and 
cause injury.

• Do not allow children to play on or around the 

unit as they could be injured.

• Placing a flower vase or other containers with 

water or other liquids on the unit could result 
in a shock hazard or fire if a spill occurs.

• Do not put a finger or other objects into the air 

inlet or air outlet. 

The fan is rotating at high speed and will cause 
injury.

• The heat exchanger fins are sharp enough to 

cut. To avoid injury wear gloves or cover the 
fins while working around them.

Do not touch the air outlet or the horizontal flaps 
while the swing flap is in operation as fingers may 
get caught and injured.

• Be sure to establish an earth.

Do not earth the unit to a utility pipe, arrester, or 
telephone earth.
Incomplete earth may cause electrical shock, or 
fire.
A high surge current from lightning or other 
sources may cause damage to the air conditioner.

• Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may 
result in electric shocks, or fire.

• Never touch the internal parts of the control-

ler.

Do not remove the front panel because some 
parts inside are dangerous to touch. In addition, 
some parts may be damaged. For checking and 
adjusting internal parts, contact your dealer.

• Do not touch the air outlet or horizontal blades 

while the swing flap is in operation because 
fingers could get caught and injured.

CAUTION

• Do not use the air conditioner for other pur-

poses.

In order to avoid any quality deterioration, do not 
use the unit for cooling precision instruments, 
food, plants, animals or works of art.

• Do not place items under the indoor unit 

which may be damaged by water.

Condensation may form if the humidity is above 
80% or if the drain outlet gets blocked.

• Avoid placing the controller in a spot 

splashed with water.

Water coming inside the air conditioner may 
cause an electric leak or may damage the internal 
electronic parts.

• Do not operate the air conditioner when using 

a room fumigation - type insecticide.

Failure to observe could cause the chemicals to 
become deposited in the unit, which could endan-
ger the health of those who are hypersensitive to 
chemicals.

• Do not turn off the power immediately after 

stopping operation.

Always wait at least 5 minutes before turning off 
the power. Otherwise, water leakage and trouble 
may occur.

• The appliance is not intended for use by 

young children or infirm persons without 
supervision.

• The remote controller should be installed in 

such away that children cannot play with it.

• Consult with installation contractor for clean-

ing the inside of the air conditioner.

Wrong cleaning may make the plastics parts bro-
ken or cause failure of water leakage or electric 
shock.

• Do not touch the air inlet or aluminium fin of 

the air conditioner.

Otherwise, injury may be caused.

• Do not place objects in direct proximity of the 

outdoor unit and do not let leaves and other 
debris accumulate around the unit.

Leaves are a hotbed for small animals which can 
enter the unit. Once in the unit, such animals can 
cause malfunctions, smoke or fire when making 
contact with electrical parts.

01_EN_3PN05140-8W.fm  Page 6  Wednesday, September 14, 2005  2:06 PM

Summary of Contents for FCQ24MVJU

Page 1: ...FCQ24MVJU FCQ30MVJU FCQ36MVJU FCQ42MVJU OPERATION MANUAL Read these instructions carefully before installation Keep this manual in a handy place for future reference This manual should be left with t...

Page 2: ...2 00_3PN05140 8W_CV2 fm Page 2 Monday September 5 2005 2 30 PM...

Page 3: ...3 1 3 4 2 TEST F hr hr TEST NOT AVAILABLE L H 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 a b c d e e f g h i k e f l d j F hr H 00_3PN05140 8W_CV2 fm Page 1 Monday September 5 2005 2 30 PM...

Page 4: ...igure 2 on page 3 Please read these SAFETY CONSIDERATIONS carefully before installing air conditioning equipment and be sure to install it correctly After completing the installation make sure that th...

Page 5: ...dren will not play with them Chil dren playing with plastic bags face the danger of death by suffocation WARNING It is not good for your health to expose your body to the air flow for a long time Ask...

Page 6: ...In order to avoid any quality deterioration do not use the unit for cooling precision instruments food plants animals or works of art Do not place items under the indoor unit which may be damaged by...

Page 7: ...eral oil such as cutting oil b Where there is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as a fact...

Page 8: ...isplay shows the set fan speed 9 DISPLAY AIR FLOW FLAP Refer to AIR FLOW DIRECTION ADJUST 10 DISPLAY TIME TO CLEAN AIR FIL TER Refer to HOW TO CLEAN THE AIR FILTER 11 DISPLAY DEFROST Refer to DEFROST...

Page 9: ...temperature falls In this case use the air conditioner in combination with other heating systems A warm air circulating system is employed and therefore it takes some time until the entire room is war...

Page 10: ...g the stop time The sys tem stops operating after the set time has elapsed Programming the start time The sys tem starts operating after the set time has elapsed The timer can be programmed a maximum...

Page 11: ...on Turn off the main power supply switch when it is not used for long periods of time When the main power switch is turned on some watts of electric ity is being used even if the system is not operat...

Page 12: ...air filter into place 5 Shut the suction grille Refer to item No 1 6 Press the FILTER SIGN RESET BUTTON on the remote controller The display TIME TO CLEAN AIR FILTER vanishes NOTE NOTE NOTE Do not rem...

Page 13: ...HAT TO DO WHEN STOPPING THE SYS TEM FOR A LONG PERIOD Turn on FAN OPERATION for a half day and dry the unit Refer to FAN OPERATION Cut off the power supply When the main power switch is turned on some...

Page 14: ...the system is in COOLING OPERATION or at a stop The noise is heard when the drain pump is in operation A Pishi pishi squeaking sound is heard when the system is in operation or after the stop of opera...

Page 15: ...qualified service person to clean the air filters Refer to MAINTENANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outlet of the indoor or the out door unit i...

Page 16: ...1645 Wallace Drive Suite 110 Carrollton TX 75006 info daikinac com www daikinac com 0510 HT 3PN05140 8W EM04A052B 00_3PN05140 8W_CV1 fm Page 2 Thursday September 15 2005 8 53 AM...

Reviews: