4
|
About the units and options
Installer and user reference guide
21
FCAG35~140BVEB
Split system air conditioners
4P561448-1B – 2021.07
In combination with R410A outdoor units
Outdoor units
Cooling
Heating
RXS35~60
–10~46°C DB
–15~18°C WB
14~28°C WB
10~30°C DB
3MXS40~68
4MXS68~80
5MXS90
–10~46°C DB
–15~18°C WB
14~28°C WB
10~30°C DB
RZQG71~140
–15~50°C DB
–20~15.5°C WB
12~28°C WB
10~27°C DB
RZQSG71~140
–15~46°C DB
–15~15.5°C WB
14~28°C WB
10~27°C DB
RZQ200~250
–5~46°C DB
–15~15°C WB
14~28°C WB
10~27°C DB
AZQS71
–15~46°C DB
–15~15.5°C WB
14~28°C WB
10~27°C DB
AZQS100~140
–5~46°C DB
–15~15.5°C WB
14~28°C WB
10~27°C DB
Indoor humidity
≤80%
(a)
Indoor humidity
(a)
To avoid condensation and water dripping out of the unit. If the temperature or the
humidity is beyond these conditions, safety devices may be put in action and the air
conditioner may not operate.