4
For FCA50 · 60 · 71 · 85 · 100 · 125 · 140CVMA
DB: Dry bulb temperature (°C)
WB: Wet bulb temperature (°C)
The setting temperature range of the remote controller is
16°C to 32°C.
Regarding places for installation
•
Is the air conditioner installed at a well-ventilated
place where there are no obstacles around?
COOLING
d. Where there are considerable voltage fluctuations
such as a factory or plant
e. Vehicles and vessels
f. Where there is much spray of oil and vapor such as a
cookery, etc.
g. Where there are machines generating electromagnetic
waves
h. Filled with acid and/or alkaline steam or vapor
•
Is a snow protection measure taken?
For details, consult your dealer about snow protection
hoods, etc.
Regarding wiring
•
All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by yourself.
•
Make sure that a separate power supply circuit is
provided for this air conditioner and that all electrical
work is carried out by qualified personnel according
to local laws and regulations.
Pay attention to running noises, too
•
Are the following places selected?
System relocation
•
Consult your Daikin dealer about remodelling and
relocation.
a. A place that can sufficiently withstand the weight of the
air conditioner with less running noises and vibrations.
b. A place where the hot wind discharged from the air
outlet of the outdoor unit and the running noises do
not cause a nuisance to neighbours.
•
Are you sure that there are no obstacles near the air
outlet of the outdoor unit?
Such obstacles may result in declined performance and
increased running noises.
•
If abnormal noises occur in use, stop the operation
of the air conditioner, consult your dealer.
Regarding drainage of drain pipe
•
•
•
•
•
•
Is the drain pipe executed to perform complete
drainage?
If
Operation procedure
Read the operation manual attached to the remote
controller.
Operation procedure varies with heat pump type and
cooling only type. Contact your local dealer to confirm
your system type.
To protect the unit, turn on the main power supply switch
6 hours before operation.
Do not shut off the power supply during seasonal use of
the air conditioner.
This is required in order to activate the air conditioner
smoothly.
If the main power supply switch is turned off during
operation, operation will restart automatically after the
power truns back on again.
proper drainage is not carried out from the outdoor drain
pipes during air-conditioning operation, chances are that
dust and dirt are clogged in the pipe. This may result in a
water leakage from the indoor unit. Under such
circumstances, stop the operation of the air conditioner,
and then consult your dealer or our service station.
3. OPERATION RANGE
4. INSTALLATION SITE
5. OPERATION PROCEDURE
OUTDOOR
UNIT
INDOOR
OUTDOOR
TEMPERA-
TURE
TEMPERA-
TURE
HUMIDITY
D
B
21 to 32
80% or below
D
B
-5 to 50
W
B
14 to 25
D
B
21 to 32
D
B
-5 to 46
W
B
14 to 25
RZAS-B
RZAV-C
RZAC-C
OUTDOOR
UNIT
INDOOR
OUTDOOR
TEMPERA-
TURE
TEMPERA-
TURE
HUMIDITY
D
B
21 to 32
80% or below
D
B
21 to 46
W
B
14 to 25
D
B
21 to 32
D
B
-5 to 50
W
B
14 to 25
RZF-C
RZA-B
For FCF50 · 60 · 71 · 100 · 125 · 140CVM(4)
HEATING
OUTDOOR
UNIT
INDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
RZAS-B
RZA-B
RZAV-C
RZAC-C
D
B
15 to 27
D
B
–15 to 21
W
B
–15 to 16
•
Do not use the air conditioner in the following places.
a. Filled with much mineral oil such as cutting oil
c. Where sulfured gas exists such as a hot-spring resort
b. Where there is much salt such as a beach area
FCA50 · 60 · 71CAVMA