  SAFETY CONSIDERATIONS .....................................[i] [ii]
1. WHAT TO DO BEFORE OPERATION .............................. 1
2. OPERATION RANGE ...................................................... 1
3. OPERATION PROCEDURE ............................................ 2
4. MAINTENANCE  

(FOR SERVICE PERSONNEL) ....................................... 2

1.  WHAT TO DO BEFORE OPERATION

This operation manual is for the system with standard control. 
Before initiating operation, contact your Daikin dealer for the 
operation that corresponds to your system.

Indoor unit

Outdoor unit

Remote controller

If your installation has a customized control system, ask your 
Daikin dealer for the operation that corresponds to your sys-
tem.

• 

Heat pump type
This system provides cooling, heating, automatic, drying 
and fan operation modes.

• 

Cooling only type
This system provides cooling, drying and fan operation 
modes.

PRECAUTIONS FOR TWO REMOTE CONTROLLERS 

CONTROL SYSTEM

This system provides another control system beside individual 
control (one remote controller controls one indoor unit) sys-

tem. Confirm the following if your unit is the following control 

system type.

• 

Two remote controllers control system

Two remote controllers control one indoor unit.
The unit is individually operated.

NOTE 

• 

Contact your Daikin dealer in case of changing setting of 
two remote controllers control system.

Names and functions of parts

a

b

c

d

e

f

g

h

i

j

k

l

m

n

o

p

a

Drain pump

 (Built-in)

b

Drain pan inspection window

c

Remote controller

 (Optional accessory)

Depending on the system configuration, the remote 

controller is not provided.

d

Power supply wiring

e

Discharge grille

f

Discharge duct

g

Refrigerant piping

h

Drain piping

i

Name plate

j

Air filter

k

Suction filter chamber

l

Suction duct

m

Suction grille

n

Ground wiring

The wiring passes electricity from the indoor unit to 
the earth to prevent accidental electric shock.

o

Transmission wiring

p

Remote controller wiring

2.  OPERATION RANGE

If the temperature or the humidity is beyond the following 
conditions, safety devices may work and the air conditioner 
may not operate, or sometimes, water may drop from the 
indoor unit.

OPERATION

TEMPERATURE

OUTDOOR

INDOOR

COOLING

23 to 122°F DB
(-5 to 50°C DB)

57.2 to 77°F WB
(14 to 25°C WB)

HEATING

-4 to 60°F WB

(-20 to 15.5°C WB)

59 to 80.6°F DB
(15 to 27°C DB)

DB:  Dry bulb temperature (°F (°C))
WB: Wet bulb temperature (°F (°C))

The setting temperature range of the remote controller is 60°F 
(16°C) to 90°F (32°C).