background image

English

8

When the display shows “

 

 (TIME TO CLEAN 

AIR FILTER), ask a qualified service person to 
clean the filters (Referó to MAINTENANCE).

ONLY A QUALIFIED SERVICE PERSON IS 
ALLOWED TO PERFORM MAINTENANCE

IMPORTANT!

• BEFORE OBTAINING ACCESS TO TERMINAL 

DEVICES, ALL POWER SUPPLY CIRCUITS 
MUST BE INTERRUPTED

To clean the air conditioner, be sure to stop oper-
ation, and turn the power switch off. Otherwise, an 
electric shock and injury may result.

Do not wash the air conditioner with water
Doing so may result in an electric shock.

Be careful with a scaffold or staging
Caution must be exercised because of work at a 
high place.

HOW TO CLEAN THE AIR FILTER

Clean the air filter when the display shows “

” 

(TIME TO CLEAN AIR FILTER). 
Increase the frequency of cleaning if the unit is 
installed in a room where the air is extremely 
contaminated.
(As a yardstick for regulating yourself, consider 
cleaning the filter once every two weeks.)

1. Remove the air filters.

Pull the handle in the direction of the arrow.  

2. Clean the air filter.

Use vacuum cleaner 

A)

 or 

wash the air filter with water

 B).

A)

Using a vacuum cleaner

8. MAINTENANCE

(FOR SERVICE PERSONNEL)

B)

Washing with water
When the air filter is very 
dirty, use soft brush and 
neutral detergent.

Remove water and dry in the shade.

NOTE

Do not wash the air conditioner with hot water of 
more than 50°C, as doing so may result in discol-
oration and/or deformation.

Do not expose it to fire, as doing so may result in 
burning.

3. Reset the air filter in place.

After cleaning the filter, do not forget to put it 
back the way it was before.

4. Press the FILTER RESET button on the 

remote controller.

The display “ 

”(TIME TO CLEAN AIR FILTER) 

vanishes.

HOW TO CLEAN AIR OUTLET AND OUT-

SIDE PANELS

Clean with soft cloth.

When it is difficult to remove stains, use water or 
neutral detergent.

NOTE

Do not use gasoline, benzene, thinner, polishing 
powder, liquid insecticide. It may cause discolor-
ing or warping.

Do not use water or air of 50°C or higher for clean-
ing air filters and outside panels.

START UP AFTER A LONG STOP

Confirm the following

Check that the air inlet and outlet are not blocked.
Remove any obstacle.

Check if the earth is connected.
Might there be a broken wire somewhere?
Contact your dealer if there are any problems.

Clean the air filter and outside panels

After cleaning the air filter, make sure to attach it.

Turn on the main power supply switch

The display on the remote controller will be shown 
when the power is turned on.

To protect the unit, turn on the main power switch 
at least 6 hours before operation.

01_EN_3P170549-3.fm  Page 8  Friday, December 9, 2005  11:45 AM

Summary of Contents for FAY71FVE

Page 1: ...ANDY PLACE FOR FUTURE REFERENCE LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER ALGUNA DUDA MODELS Wall mounted type FAY71FVE...

Page 2: ...ng the manual file it away for future reference Le agradecemos la compra de este acondicio nador de aire Daikin Lea cuidadosamente el manual de funciona miento antes de utilizar el acondicionador de a...

Page 3: ...4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 10 11 3 1 4 5 6 7 8 14 15 16 17 18 19 20 21 22 12 9 13 R Y 71 b d f k e i h a j d f g e c R Y 100 C hr H 00_CV_3P170549 3 fm Page 2 Friday December 9 2005 1...

Page 4: ...SYSTEM This system provides two other control systems beside individual control one remote controller con trols one indoor unit system Confirm the following if your unit is of the following control s...

Page 5: ...r dealer When the air conditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the limiting concentration e...

Page 6: ...wise injury may be caused Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can...

Page 7: ...result in a water leakage from the indoor unit Under such circumstances stop the operation of the air conditioner and then consult your dealer or our service station Refer to figure 1 on page 1 The il...

Page 8: ...planation all indications are shown on the display in figure 1 contrary to actual running situations 6 OPERATION PROCEDURE COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION OPERATION MODE SELEC...

Page 9: ...t AIR FLOW DIRECTION ADJUST There are 2 ways of adjusting the air discharge angle ADJUSTMENT A Up and down adjustment B Left and right direction A UP AND DOWN DIRECTION Press the AIR FLOW DIRECTION AD...

Page 10: ...dure from to once again When the timer is programmed to stop the system after 3 hours and start the system after 4 hours the system will stop after 3 hours and then 1 hour later the system will start...

Page 11: ...ush and neutral detergent Remove water and dry in the shade NOTE Do not wash the air conditioner with hot water of more than 50 C as doing so may result in discol oration and or deformation Do not exp...

Page 12: ...E AIR CONDITIONER II WHITE MIST COMES OUT OF A UNIT When humidity is high during cooling opera tion In oily or dusty places If the inside of an indoor unit is extremely contam inated the temperature d...

Page 13: ...lfunction occurs UNIT No C L H Check if no fuse has blown Turn off the power supply Check if the breaker is blown Turn the power on with the breaker switch in the off position Do not turn the power on...

Page 14: ...9 CURRENT INPUT RAT ING A 17 4 22 6 CAPACITY kW 8 5 11 8 kcal h 7300 10100 WEIGHT OF INDOOR UNIT kg 26 27 26 27 WEIGHT OF OUTDOOR UNIT kg 87 117 91 120 REFRIGERANT R22 R22 R22 R22 MASS OF REFRIGERANT...

Page 15: ...3P170549 3 EM95A057F 0602 HT 00_CV_3P170549 3 fm Page 4 Friday December 9 2005 1 46 PM...

Reviews: