background image

Procedure to Remove Heat Exchanger

Si211309E

10

Removal Procedure

8. Procedure to Remove Heat Exchanger 

Procedure

Warning      Be sure to wait for 10 minutes or more after turning off all power 

supplies before disassembling work.

Step

Procedure

Points

Before dismounting a heat 

exchanger, make sure to 
proceed pump down 
refrigerant to outdoor unit and 
disconnect the connection 
pipe and wiring, then remove 
the indoor unit.

1

Dismount top plate.

2

Remove the 3 setting 
screws for heat 
exchanger and 1 screw 
for pipe fixing box.

There is a hock right hand side 
behind the heat exchanger.

Top plate

Pipe fixing box

Summary of Contents for FAY71FAVE

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Indoor Unit Non Inverter Pair Type 3 HP Class Si211309E...

Page 2: ...Service Manual Removal Procedure Indoor Unit Applicable Models zHeat Pump FAY71F A VE...

Page 3: ...e Panel Operation Display Cover and Front Grille 3 3 Procedure to Remove Electrical Parts Box 4 4 Procedure to Remove PCB 5 5 Procedure to Remove Swing Louvre Unit 6 6 Procedure to Remove Fan Motor 7...

Page 4: ...e 1 Procedure to Remove Air Filter Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 Hold the air filter t...

Page 5: ...fore disassembling work Step Procedure Points 1 Remove the left and right side panels 1 white screw each on left and right The wiring diagram is applied to the right side panel and troubleshooting lis...

Page 6: ...els operation display cover and front grille according to the procedures for their removal 1 Remove the 1 thermistor 2 heater connector and 3 rubber clip connected to the PCB 2 Remove the 2 screws fas...

Page 7: ...anels according to the procedure for removing the electrical parts box 1 Disconnect the front side wiring connector connected to the PCB 2 Disconnect the PCB from the tabs by pushing it inward Draw th...

Page 8: ...s or more after turning off all power supplies before disassembling work Step Procedure Points Remove the electrical parts box according to its removal procedure 1 Remove the horizontal blade 2 Remove...

Page 9: ...sembling work Step Procedure Points Remove side panels and other external casing and electrical parts box according to their removal procedures Use 2 5 mm hexagon nut driver 1 Loosen the hexagon set s...

Page 10: ...Carry out pump down disconnect the transmission piping and wiring and remove the main unit Remove side panels operation display cover and front cover according to their removal procedures 1 Remove the...

Page 11: ...moval Procedure 9 3 Remove the air discharge unit 7 screws Center of air discharge section also screw fastened 4 Remove the drain pan 1 Pull left side toward yourself 2 Move the drain hose to the righ...

Page 12: ...ore disassembling work Step Procedure Points Before dismounting a heat exchanger make sure to proceed pump down refrigerant to outdoor unit and disconnect the connection pipe and wiring then remove th...

Page 13: ...cedure Points Remove the heat exchanger according to its removal procedure You can also remove the auxiliary electric heater without removing the heat exchanger 1 Remove the 2 screws of the left side...

Page 14: ...Revision History Month Year Version Revised contents 06 2013 Si211309E First edition...

Page 15: ...oduct The User s Manual provides important safety instructions and warnings Be sure to follow these instructions and warnings If you have any enquiries please contact your local importer distributor a...

Reviews: