The following symptoms do not indicate air 

conditioner malfunction

HEATING OPERATION within 6 hours after the 
power is supplied to the air conditioner.
Some models perform the following operation to 
protect the devices.
If the HEATING OPERATION is performed within 6 
hours after the power is supplied to the air 

 

The above operation is performed not only at the 
time of installation, but every time the power 
circuit breaker is turned off/on.
For comfort heating, it is recommended not to turn 
off the power circuit breaker during the HEATING 
OPERATION.

1. THE AIR CONDITIONER DOES NOT OPERATE

• The air conditioner does not restart 

immediately after the ON/OFF button is 
pressed.

• The air conditioner does not restart 

immediately when TEMPERATURE 

SETTING button is returned to the former 

position after pushing the button.

If the OPERATION lamp lights, the air 
conditioner is in normal condition.
It does not restart immediately because a 
safety device operates to prevent overload of 
the air conditioner.
After approx. 3 minutes, the air conditioner 
will turn on again automatically.

• The air conditioner does not start when 

the display shows “

” and it 

flashes for few seconds after pressing an 

operation button.

This is because the air conditioner is under 
centralized control.
Flashes on the display indicates that the air 
conditioner cannot be controlled by the 
remote controller.

• HEATING OPERATION within 6 hours 

after the power is supplied to the air

conditioner.

Some models perform the following 
operation to protect the devices.
If the HEATING OPERATION is performed 
within 6 hours after the power is supplied to 
the air conditioner, the indoor fan stops for 
about 10 minutes during the outdoor unit 
operation to protect the devices.
The above operation is performed not only at 
the time of installation, but every time the 
power circuit breaker is turned off/on.

9. NOT MALFUNCTION OF THE 

AIR CONDITIONER

For comfortable use, do not turn off the 
power circuit breaker during seasonal use of 
the HEATING OPERATION.

• The outdoor unit stops.

This is because the indoor temperature has 
reached the set temperature.
The indoor unit is in the FAN OPERATION.

COOLING OPERATION 
(AUTOMATIC COOLING OPERATION):
Lower the set temperature.
HEATING OPERATION 
(AUTOMATIC HEATING OPERATION):
Raise the set temperature.

The operation starts after a while when the 
air conditioner is in normal condition.

• The remote controller displays “

”, 

and airflow stops.

This is because the air conditioner 
automatically switches to the DEFROST 
OPERATION to prevent a decrease in 
heating capacity when frost on the outdoor 
unit increases.
After maximum 10 minutes, the air conditioner 
returns to its original operation.

2. THE OPERATION SOMETIMES STOPS

• The remote controller displays “U4” and 

“U5”, and the operation stops. However, it 

will restart in a few minutes.

This is because communication between the 
indoor and outdoor units or indoor units and 
remote controllers is shut off and stops the 
operation due to noise caused by devices 
other than the air conditioner.
When the electrical noise decreases, the air 
conditioner automatically restarts.

3. THE FAN SPEED IS DIFFERENT FROM THE 

SETTING

• Pressing the fan speed control button 

does not change the fan speed.

During the COOLING OPERATION, the low 
fan speed or a gentle wind is used to prevent 
the discharge of melt water.
During the DEFROST OPERATION 
(HEATING OPERATION), the wind from the 
air conditioner stops to prevent air discharge 
directly toward your body.
After a while, the fan speed can be changed.
(The fan speed cannot be set for the 
PROGRAM DRY OPERATION.)
When the room temperature reaches the set 
temperature during the HEATING 
OPERATION, the outdoor unit stops and the 
indoor unit goes into gentle wind.
It takes some time until the fan speed 
changes. Raise the set temperature. After a 
while, the fan speed changes.

conditioner, the indoor fan stops for about 10 minutes
during the outdoor unit operation to protect the devices.

Summary of Contents for FAA50BAVMA

Page 1: ...SPLIT SYSTEM Air Conditioners OPERATION MANUAL MODELS Wall mounted type FAA71BVMA FAA60BAVMA FAA50BAVMA FAA85BVMA FAA100BVMA...

Page 2: ......

Page 3: ...reading the manual file it away for future reference Furthermore make certain that this operation manual is handed to a new user when he takes over the operation As this operation manual is dedicated...

Page 4: ...ipment is transferred to a new user be sure also to hand over the manual The precautions described herein are classi ed as WARNING and CAUTION They both contain important information regarding safety...

Page 5: ...Contact professional personnel about attachment of accessories and be sure to use only accessories specified by the manufacturer If a defect results from your own workmanship it may result in water l...

Page 6: ...cy ensure that the room is adequately ventilated if equipment such as a burner is used together with the air conditioner Do not leave the remote controller wherever there is a risk of wetting If water...

Page 7: ...ged use check the unit stand and its mounts for damage If left in a damaged condition the unit may fall and cause injury Arrange the drain hose to ensure smooth drainage Imperfect drainage may cause w...

Page 8: ...rol systems beside individual control one remote controller controls one indoor unit system Confirm the following if your unit is the following control system type Group control system One remote cont...

Page 9: ...er consult your local dealer 4 INSTALLATION SITE Operating procedure varies with heat pump type and cooling only type Contact your local dealer to confirm your system type To protect the air condition...

Page 10: ...air temperature and heating capacity The heating capacity of the air conditioner declines as the outside air temperature falls In such a case use the air conditioner in combination with other heating...

Page 11: ...ING AUTOMATIC COOLING PROGRAM DRY HEATING AUTOMATIC HEATING Up and down direction When operating continuously at downward airflow direction Air blows in the automaticallyset direction for a period of...

Page 12: ...nd remote controller Images may become fuzzy and noise may be generated 7 OPTIMUM OPERATION Turn off the power circuit breaker when it is not in use for a long period When the power circuit breaker is...

Page 13: ...You may change the time of indication or Time to clean filter If the indoor unit is used in a space where the air is more contaminated ask your local dealer for solution If it becomes difficult to re...

Page 14: ...to the remote controller The indication can be turned off whether in operation or at stop 11 CAUTION Hold the front panel firmly so that it does not fall Do not use water which is 50 C or more benzen...

Page 15: ...t turn off the power circuit breaker during seasonal use of the HEATING OPERATION WHAT TO DO TO STOP THE AIR CONDITIONER FOR A LONG PERIOD Turn on FAN OPERATION for a half day on the fine day and dry...

Page 16: ...MALFUNCTION OF THE AIR CONDITIONER For comfortable use do not turn off the power circuit breaker during seasonal use of the HEATING OPERATION The outdoor unit stops This is because the indoor temperat...

Page 17: ...nit Ask your local dealer for details on cleaning the indoor unit This cleaning requires a qualified service person Check the usage environment When the air conditioner is changed over to the HEATING...

Page 18: ...lades at the air outlet are closed while the indoor stops Check if the air filter is clogged Ask a qualified service person to clean the air filters A decrease in the airflow volume of the air conditi...

Page 19: ...nected Contact the central control room that directed the stop Are you sure that the display for centralized control is not lit Contact the central control room that directed the stop If the problem i...

Page 20: ...3P427030 3R M15N111D 2110 HT The two dimensional bar code is a manufacturing code...

Reviews: