![background image](http://html1.mh-extra.com/html/daikin/ewaq006bavp/ewaq006bavp_installers-reference-manual_3372780091.webp)
6/7
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.8
[9-00]
R/W
37~55°C, step: 1°C
55°C
A.8
[9-01]
R/W
15~37°C, step: 1°C
25°C
A.8
[9-02]
R/W
18~22°C, step: 1°C
22°C
A.8
[9-03]
R/W
5~18°C, step: 1°C
5°C
A.8
[9-04]
R/W
1~4°C, step: 1°C
1°C
A.8
[9-05]
25
A.8
[9-06]
55
A.8
[9-07]
5
A.8
[9-08]
22
A.8
[9-09]
R/W
3~10°C, step: 1°C
5°C
A.8
[9-0A]
R/W
3~10°C, step: 1°C
5°C
A.8
[9-0B]
R/W
0: Quick
1: Slow
A.8
[9-0C]
R/W
1~6°C, step: 0,5°C
1 °C
A.8
[9-0D]
R/W
0~8, step:1
0 : 100%
1~4 : 80~50%
5~8 : 80~50%
6
A.8
[9-0E]
6
A.8
[A-00]
0
A.8
[A-01]
0
A.8
[A-02]
0
A.8
[A-03]
0
A.8
[A-04]
0
A.8
[B-00]
0
A.8
[B-01]
0
A.8
[B-02]
0
A.8
[B-03]
0
A.8
[B-04]
0
A.8
[C-00]
0
A.8
[C-01]
0
A.8
[C-02]
R/W
0: No
1: Bivalent
2: -
3: -
A.8
[C-03]
R/W
-25~25°C, step: 1°C
0°C
A.8
[C-04]
R/W
2~10°C, step: 1°C
3°C
A.8
[C-05]
R/W
1: Thermo ON/OFF
2: C/H request
A.8
[C-06]
1
A.8
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
A.8
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
A.8
[C-09]
R/W
0: Normally open
1: Normally closed
A.8
[C-0A]
0
A.8
[C-0C]
R/W
0~7
0
A.8
[C-0D]
R/W
0~7
0
A.8
[C-0E]
R/W
0~7
0
A.8
[D-00]
R/W
0~3
0: None
2: BUH only
3: All heaters
A.8
[D-01]
R/W
0~3
0: No
1: Open tariff
2: Closed tariff
A.8
[D-02]
0
A.8
[D-03]
R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
A.8
[D-04]
R/W
0: No
1: Yes
A.8
[D-05]
R/W
0: Forced off
1: As normal
A.8
[D-07]
0
A.8
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.8
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.8
[D-0A]
0
A.8
[D-0B]
2
A.8
[D-0C]
R/W
0~49
0
A.8
[D-0D]
R/W
0~49
0
A.8
[D-0E]
R/W
0~49
0
Is an external kWh meter used for power measurement?
--
--
What is the high electricity price (Do not use)
What is the medium electricity price (Do not use)
What is the low electricity price (Do not use)
Leaving water temperature compensation around 0°C.
Is the option box used for PCC ?
Forced off contact type
Is the pump allowed to run if prefer. kWh rate PS is cut?
--
Is an external kWh meter used for power measurement?
--
High electricity price decimal (Do not use)
Medium electricity price decimal (Do not use)
Low electricity price decimal (Do not use)
Which heaters are permitted if prefer. kWh rate PS is cut?
--
Bivalent hysteresis temperature.
What is the thermo request contact type for the main zone?
--
What is the unit control method in space operation?
Which type of external sensor is installed?
What is the required alarm output contact type?
--
--
--
--
Is an external backup heat source connected?
Bivalent activation temperature.
--
--
--
--
--
--
What emitter type is connected to the main LWT zone?
Room temperature hysteresis.
Pump speed limitation
--
--
--
--
--
--
--
What is the desired delta T in heating?
What is the desired delta T in cooling?
What is the maximum desired LWT for main zone in heating?
What is the minimum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
What is the minimum desired LWT for main zone in cooling?
Leaving water temperature overshoot temperature.
4P478618-1B - 2017.06
(*1) EWYQ*_(*2) EWAQ*