7
|
Unit installation
Installer reference guide
62
EPRA14~W1 + ET9W
Daikin Altherma 3 H HT F
4P644739-1 – 2021.02
7.3.6 To install the discharge grille
INFORMATION
Electrical wiring.
Before installing the discharge grille, connect the electrical wiring.
Install the lower part of the discharge grille
1
Insert the hooks.
2
Insert the ball studs.
1
2
3
Fix the 2 lower screws.
3
2×
5 N•m
Install the upper part of the discharge grille
NOTICE
Vibrations.
Make sure the upper part of the discharge grille is attached seamlessly to
the lower part to prevent vibrations.
4
Align and attach the left side.
5
Align and attach the middle part.
6
Align and attach the right side.