2 Specific installer safety instructions
Installation manual
5
ETBH/X16E
Daikin Altherma 3 H HT W
4P644727-1B – 2022.03
Technical engineering data
▪ A
subset
of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The
full set
of latest technical data is available on the Daikin
Business Portal (authentication required).
Online tools
In addition to the documentation set, some online tools are available
for installers:
▪
Daikin Technical Data Hub
▪ Central hub for technical specifications of the unit, useful tools,
digital resources, and more.
▪ Publicly accessible via
https://daikintechnicaldatahub.eu
▪
Heating Solutions Navigator
▪ Digital toolbox that offers a variety of tools to facilitate the
installation and configuration of heating systems.
▪ To access Heating Solutions Navigator, registration to the
Stand By Me platform is required. For more information, see
https://professional.standbyme.daikin.eu
.
▪
Daikin e-Care
▪ Mobile app for installers and service technicians that allows you
to register, configure and troubleshoot heating systems.
▪ The mobile app can be downloaded for iOS and Android
devices using the QR codes below. Registration to the Stand
By Me platform is required to access the app.
App Store
Google Play
2
Specific installer safety
instructions
Always observe the following safety instructions and regulations.
Installation site (see
"4.1 Preparing the installation site"
WARNING
Follow the service space dimensions in this manual for
correct installation of the unit. See
requirements of the indoor unit"
Opening and closing the unit (see
7])
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
Mounting the indoor unit (see
8])
WARNING
Fixing method of the indoor unit MUST be in accordance
with the instructions from this manual. See
8].
Piping installation (see
8])
WARNING
Field piping method MUST be in accordance with the
instructions
from
this
manual.
See
In case of freeze protection by glycol:
WARNING
Ethylene glycol is toxic.
WARNING
Due to the presence of glycol, corrosion of the system is
possible. Uninhibited glycol will turn acidic under the
influence of oxygen. This process is accelerated by the
presence of copper and high temperatures. The acidic
uninhibited glycol attacks metal surfaces and forms
galvanic corrosion cells that cause severe damage to the
system. Therefore it is important that:
▪ the water treatment is correctly executed by a qualified
water specialist,
▪ a glycol with corrosion inhibitors is selected to
counteract acids formed by the oxidation of glycols,
▪ no automotive glycol is used because their corrosion
inhibitors have a limited lifetime and contain silicates
which can foul or plug the system,
▪ galvanized pipes are NOT used in glycol systems since
the presence may lead to the precipitation of certain
components in the glycol's corrosion inhibitor.
Electrical installation (see
DANGER: RISK OF ELECTROCUTION
WARNING
Electrical wiring connection method MUST be in
accordance with the instructions from:
▪ This manual. See
11].
▪ The wiring diagram, which is delivered with the unit,
located on the inside of the indoor unit switch box
cover. For a translation of its legend, see
36].
WARNING
▪ All wiring MUST be performed by an authorised
electrician and MUST comply with the applicable
legislation.
▪ Make electrical connections to the fixed wiring.
▪ All components procured on-site and all electrical
construction MUST comply with the applicable
legislation.
WARNING
ALWAYS use multicore cable for power supply cables.
WARNING
If the supply cord is damaged, it MUST be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
CAUTION
Do NOT push or place redundant cable length in the unit.
WARNING
The backup heater MUST have a dedicated power supply
and MUST be protected by the safety devices required by
the applicable legislation.
Summary of Contents for ETBH16E 6V Series
Page 39: ......