background image

Outdoor Unit • Daikin Altherma flex type• EMRQ-A

1

9

Heating • Daikin Altherma flex type

18

9

Wiring diagrams

9 - 1 Wiring Diagrams - Single Phase

1TW59926-3

EMRQ14-16A

A1P

A8P

Printed circuit board

A1P: Main

A4P,A7P: Noise filter

A2P: Sub 1

A5P, A8P: Inverter

A3P: Sub 2

A6P,A9P: Fan

BS1

BS5

Push button switch (Mode, set, return, test, reset)

C1, C63, C66

Capacitor

E1HC, E2HC

Crankcase heater (A1P, A3P)

F1U, F2U

Fuse (T, 3.15A, 250V) (A1P, A3P)

F1U

Fuse (T, 3.15A, 250V) (A2P)

F1U

Fuse (8A, DC650V) (A6P, A9P)

F5U

Field fuse

F400U

Fuse (T, 6.3,250V) (A4P)(A7P)

H1P

H8P

Pilot lamp (service monitor-orange)

[H2P] Prepare test----Flickering

Malfunction detection----Light up

HAP

Pilot lamp (Service monitor green) (A1P A2P A3P)

K1

K4

K1: Magnetic relay (A5P,A8P)

K3: Magnetic relay (A4P,A7P)

K2: Magnetic contactor (M1C-A5P,M2C-A8P)

K4: Magnetic contactor (M1C-A4P,M2C-A7P)

K1R

K8R, K11R

Magnetic relay

K1R: Y4S

K5R: For option (A2P)

K2R: Y5S

K5R Y9S (A3P)

K3R: Y1S (A1P)

K6R: Y7S (A2P)

K3R: Y6S (A2P)

K7R: E1HC (A1P)

K4R: Y8S

K7R: (E2HC) (A3P)

K5R: Y2S (A1P)

K11R: Y10S (A3P)

L1R

Reactor

M1C, M2C

Motor (Compressor)

M1F, M2F

Motor (Fan)

PS

Switching power supply (A1P, A3P, A5P,A8P)

Q1DI

Earth leakage breaker

Q1RP

Reverse phase detection circuit (A1P, A3P)

R10

Resistor (current sensor) (A6P, A7P)

R50, R59

Resistor (A5P,A8P)

R90

Resistor (current sensor) (A5P,A8P)

R95

Resistor (current limiting) (A5P,A8P)

R1T

R15T

R31T, R32T

Thermistor

R1T: Air (A1P)

R8T: Suction 1

R1T: Fin (A5P,A8P)

R9T: Liquid

R2T: H/E gas 1

R10T: Suction 2

R31T: M1C Discharge

R11T: H/E gas 2

R32T: M2C Discharge

R12T: H/E deicer 2

R4T: H/E deicer 1

R13T: Subcool H/E gas 2

R5T: Subcool H/E gas 1

R14T: Liquid 2

R6T: Subcool H/E Liq

R15T: H/E Liquid 2

R7T: H/E Liquid 1

S1NPH

Pressure sensor (high)

S2NPL

Pressure sensor (Pressure sensor (low))

S1PH, S2PH

Pressure switch (high)

T1A

Current sensor

SD1

Safety devices input (A1P, 3AP)

V1R

Diode bridge (A5P,A8P)

Power module (A6P,A9P)

V2R

Power module (A5P,A8P)

X1A

X9A

Connector

X1M

Terminal strip (Power supply)

X1M

Terminal (Control) (A1P,A3P)

X2M

Terminal strip (Relay)

Y1E

Electronic expansion valve (Main 1)

Y2E

Electronic expansion valve (Subcool 1)

Y3E

Electronic expansion valve (Main 2)

Y4E

Electronic expansion valve (Charge)

Y5E

Electronic expansion valve (Subcool 2)

Female connector WHT

Male connector BLU

(Note 5) Indoor

To

in/d

unit

To

out/d

unit

To

multi

unit

(Note 4)

Male connector BLU

Female connector WHT

Female connector WHT

Male connector BLK

(Note 4)

POWER
SUPPLY

3/N

380-415V 50Hz

El. Compo. Box 2

El. Compo. Box 1

Front layer

Rear layer

Position of M1,2C, M1,2F

El. Compo. Box 2 El. Compo. Box 1

Outer shell

Wiring diagram

sticker

Detail of M1C, M2C

Notes:

1 This wiring diagram only applies to the outdoor unit
2

g

: Field wiring

3

D

: Terminal strip

F

: Fixed connector

R

: Protective earth (screw)

G

: Terminal

4 When using the option adaptor, refer to the installation manual
5 Refer to the installation manual for connection wiring to indoor - outdoor unit transmission F1-F2 and

how to use BS1-BS5

6 Do not operate the unit by short-circuiting any protection device S1Ph, S2PH.
7 BLK = Black

RED = Red

YLW = Yellow

WHT = White

PNK = Pink

BRN = Brown

GRY = Grey

GRN = Green

ORG = Orange

BLU = Blue

14,16 HP

To multi

unit

Front layer

Rear layer

Y1S

Y10S

Solenoid valve

Y1S: RMTG

Y6S: RMTT

Y2S: 4 way valve

Y7S: RMTO

Y3S: RMTL

Y8S: 4 way valve (pipe)

Y4S: hot gas

Y9S: 4 way valve (H/E 2)

Y5S: EV Bypass 1

Y10S: EV Bypass 2

Z1

Z8C

Noise filter (Ferrite core)

Z1F

Noise filter (with surge absorber) (A4P,A7P)

Connector for optional parts

X7A

Refer to the installation manual for connection wiring to indoor -

outdoor unit transmission F1-F2 and how to use BS1-BS5 (A2P)

X9A

Power supply (Adapter) (A2P)

X37A

Power supply (Adapter) (A3P)

Summary of Contents for EMRQ8A

Page 1: ...Heating Technical Data Daikin Altherma flex type EEDEN12 726 EMRQ A...

Page 2: ......

Page 3: ...acity tables 7 Heating Capacity Tables 7 Integrated Heating Capacity Correction Factor 10 Capacity Correction Factor 11 6 Dimensional drawings 14 Dimensional Drawings 14 7 Centre of gravity 15 Centre...

Page 4: ...n A l t h The ultimate heating solution for residential and commercial applications based on air to water heat pump technology Customised to meet your building s needs up to 10 indoor units can be co...

Page 5: ...antity 2 Type Hermetically sealed scroll compressor Starting method Soft start Crankcase heater Quantity 2 Operation range Heating Min CWB 15 Max CWB 20 Domestic hot water Ambien t Min CDB 15 Max CDB...

Page 6: ...IEC 61000 3 11 European international technical standard setting the limits for voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated 75A 7 Max...

Page 7: ...3 1 3 Heating Daikin Altherma flex type 5 Outdoor Unit Daikin Altherma flex type EMRQ A 3 Selection procedure 3 1 Selection Procedure...

Page 8: ...Outdoor Unit Daikin Altherma flex type EMRQ A 1 4 Heating Daikin Altherma flex type 6 4 Combination table 4 1 Combination Table...

Page 9: ...3 1 5 Heating Daikin Altherma flex type 7 Outdoor Unit Daikin Altherma flex type EMRQ A 5 Capacity tables 5 1 Heating Capacity Tables...

Page 10: ...Outdoor Unit Daikin Altherma flex type EMRQ A 1 5 Heating Daikin Altherma flex type 8 5 Capacity tables 5 1 Heating Capacity Tables...

Page 11: ...3 1 5 Heating Daikin Altherma flex type 9 Outdoor Unit Daikin Altherma flex type EMRQ A 5 Capacity tables 5 1 Heating Capacity Tables...

Page 12: ...Outdoor Unit Daikin Altherma flex type EMRQ A 1 5 Heating Daikin Altherma flex type 10 5 Capacity tables 5 2 Integrated Heating Capacity Correction Factor...

Page 13: ...1 heating D The correction factor for capacity when H 0m 0 85 cooling EXAMPLE Equivalent length Equivalent length Outdoor unit Liquid pipe Size increase Branch Indoor 3TW59912 2 EMRQ10A Capacity corr...

Page 14: ...m 1 heating D The correction factor for capacity when H 0m 0 91 cooling EXAMPLE Equivalent length Equivalent length Outdoor unit Liquid pipe Size increase Branch Indoor 3TW59912 2 EMRQ14A Capacity cor...

Page 15: ...een indoor and outdoor unit outdoor unit is on highest location Hm level difference m between indoor and outdoor outdoor unit is on lowest location Model Liquid standard Liquid increase Correction fac...

Page 16: ...AAY1 J19 1 Brazing connection EMRQ10 12AAY1 J22 2 Brazing connection EMRQ14 16AAY1 Suction gas pipe J19 1 Brazing connection EMRQ8AAY1 J22 2 Brazing connection EMRQ10 12AAY1 J28 6 Brazing connection E...

Page 17: ...gravity 7 1 Centre of Gravity 3TW59924 1 EMRQ8 16A Center of foundation bolt hole Center of foundation bolt hole Slot Item A B EMR08 10 12AAY1 613 322 EMRQ14 16AAY1 609 313 Center of foundation bolt h...

Page 18: ...Outdoor Unit Daikin Altherma flex type EMRQ A 1 8 Heating Daikin Altherma flex type 16 8 Piping diagrams 8 1 Piping Diagrams...

Page 19: ...H S2PH Pressure switch high T1A Current sensor SD1 Safety devices input A1P 3AP V1R Diode bridge A5P Power module A6P A7P V2R Power module X1A X9A Connector Male connector RED Female connector WHT Fem...

Page 20: ...S1PH S2PH Pressure switch high T1A Current sensor SD1 Safety devices input A1P 3AP V1R Diode bridge A5P A8P Power module A6P A9P V2R Power module A5P A8P X1A X9A Connector X1M Terminal strip Power su...

Page 21: ...3 1 10 Heating Daikin Altherma flex type 19 Outdoor Unit Daikin Altherma flex type EMRQ A 10 Sound data 10 1 Sound Power Spectrum...

Page 22: ...Outdoor Unit Daikin Altherma flex type EMRQ A 1 10 Heating Daikin Altherma flex type 20 10 Sound data 10 1 Sound Power Spectrum...

Page 23: ...3 1 10 Heating Daikin Altherma flex type 21 Outdoor Unit Daikin Altherma flex type EMRQ A 10 Sound data 10 2 Sound Pressure Spectrum...

Page 24: ...Outdoor Unit Daikin Altherma flex type EMRQ A 1 10 Heating Daikin Altherma flex type 22 10 Sound data 10 2 Sound Pressure Spectrum...

Page 25: ...artment building to be installed at identical piping distance from indoor unit I U Tank heat meter at identical distance A Space heat cooling meters at identical distance B The flow measuring unit of...

Page 26: ...month Minimum storage capacity 13 months 13 months 13 months 13 months Register kWh heat cooling values heat cooling values heat values heat values Check local regulations and heat meter documentation...

Page 27: ...at meter 12 Temperature sensors heat meter 13 Flow measuring unit of space heat and cooling meter 14 Temperature sensor space heat and cooling meter 15 Space heating and cooling applications 16 Refrig...

Page 28: ...Outdoor Unit Daikin Altherma flex type EMRQ A 1 11 Heating Daikin Altherma flex type 26 11 Installation 11 2 Refrigerant Pipe Selection...

Page 29: ...3 1 11 Heating Daikin Altherma flex type 27 Outdoor Unit Daikin Altherma flex type EMRQ A 11 Installation 11 2 Refrigerant Pipe Selection...

Page 30: ...Outdoor Unit Daikin Altherma flex type EMRQ A 1 11 Heating Daikin Altherma flex type 28 11 Installation 11 2 Refrigerant Pipe Selection...

Page 31: ...3 1 11 Heating Daikin Altherma flex type 29 Outdoor Unit Daikin Altherma flex type EMRQ A 11 Installation 11 2 Refrigerant Pipe Selection...

Page 32: ...Outdoor Unit Daikin Altherma flex type EMRQ A 1 12 Heating Daikin Altherma flex type 30 12 Operation range 12 1 Operation Range...

Page 33: ...3 1 12 Heating Daikin Altherma flex type 31 Outdoor Unit Daikin Altherma flex type EMRQ A 12 Operation range 12 1 Operation Range...

Page 34: ...ash com EEDEN12 726 06 12 Copyright Daikin The present publication supersedes EEDEN11 726 The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daiki...

Reviews: