Outdoor Unit • Daikin Altherma flex type• EMRQ-A
1
2
•
Heating • Daikin Altherma flex type
4
2
Specifications
Standard Accessories : Installation manual; Quantity : 1;
Notes
(1) Condition: Ta=7ºCDB/6ºCWB, 100% connection ratio
(2) Condition: Ta=35ºCDB, 100% connection ratio
(3) European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current \>16A and
\<= 75A per phase
(4) In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys
(system impedance)
≤
Zmax
(5) Ssc: Short-circuit power
(6) EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for
equipment with rated
≤
75A
(7) Maximum installation height difference between indoor units can be increased up to 25m with special field setting
(8) 380 V
(9) 400 V
(10) 415 V
2-2 Electrical Specifications
EMRQ8A
EMRQ10A
EMRQ12A
EMRQ14A
EMRQ16A
Power supply
Phase
3~
Frequency
Hz
50
Voltage
V
380-415
Voltage range
Min.
%
-10
Max.
%
6
Current
Zmax
Text
-
0.27
-
Recommended fuses
A
20
25
40
Current - 50Hz
Maximum running current
A
17.1
22.1
22.3
32.8
33
Minimum Ssc value
kVa
889
843
850
2,045
2,035
Wiring connections
For power supply
Quantity
4G
Remark
Select diameter and type according to national and local regulations
For connection with indoor
Qty.
2G
Remark
F1,F2
Power supply intake
Both indoor and outdoor unit