3 Preparation
Installation manual
3
EKV EKVSU260A
Daikin Altherma – Domestic hot water tank kit
4P449984-1B – 2016.11
3
Preparation
3.1
Preparing installation site
3.1.1
Installation site requirements of the
domestic hot water tank kit
INFORMATION
The domestic hot water tank kit is mounted into the indoor
unit. The use of tank kit EKVSU260A extends the height of
the indoor unit by 190 mm.
3.2
Preparing water piping
Respect the following water circuit requirements:
▪
Domestic hot water tank kit – Clean pipes.
Before installing the
domestic hot water tank kit,
all piping and fittings must be flushed
free of flux and debris. Failure to do this may cause irreparable
damage to the tank kit control valves. Flush the system by
opening the hot water tap.
▪
Domestic hot water tank kit – Drainage.
For the discharge
piping connected to the pressure relief valve of the domestic hot
water tank kit, respect the following requirements:
Item
Requirement
Pressure relief valve diameter
15 mm
Discharge pipe diameter (to pressure relief valve)
15 mm
Discharge piping diameter (from tundish)
22 mm
Discharge piping material (from tundish)
Metal
Vertical length below tundish, before first elbow or
bend
≥300 mm
Continuous fall after first elbow or bend
≥1:200
Maximum resistance
(a)
≤9 m
Resistance created by each elbow or bend
0.8 m
(a)
The maximum allowed resistance (i.e. equivalent length) is
expressed as a length of straight pipe (i.e. no elbows or
bends).
INFORMATION
All piping MUST be installed according to section G3 of the
Building Regulations.
▪
Domestic hot water tank kit – Pressure balancing.
To prevent
large pressure differences at the taps and damage to the shower
valve due to high‑pressure cold water (5 bar), provide a dedicated
2‑bar feed to both cold water and hot water taps. To do this, also
connect the cold water supply for the cold water taps to the
pressure reducing valve of the domestic hot water tank kit.
a
b
e
c
d
e
h
f
f
g
g
e
a
Cold water supply into house at 5 bar
b
To 5-bar taps
c
Pressure reducing valve (part of the domestic hot water
tank kit)
d
Indoor unit
e
Dedicated 2‑bar feed
f
Cold water taps
g
Hot water taps
▪
Domestic hot water tank kit – Secondary return.
Where the
secondary return circuits are used, an additional expansion vessel
may be required.
4
Installation
4.1
Opening the units
4.1.1
To open the indoor unit
1
Loosen and remove the 4 screws that fix the top panel.
2
Remove the top panel from the unit.
4×
4.2
Connecting the water piping
4.2.1
To connect the water piping
NOTICE
Do NOT use excessive force when connecting the piping.
Deformation of the piping can cause malfunctioning of the
unit.
INFORMATION
If you have to inspect the inside of the domestic hot water
tank, you can access it via the booster heater boss.
The installation of the domestic hot water tank kit is part of a larger
installation flow. The total installation of the water piping consists of:
1
Connecting the recirculation piping.
2
Connecting the water piping:
▪ Directly to the indoor unit: connecting the water piping to the
space heating inlet, the space heating outlet, and the domestic
hot water outlet.
▪
Via the domestic hot water tank kit: connecting the water
piping to the unit’s domestic cold water inlet, and
connecting the kit itself to the drain.
3
Connecting the pressure relief valve to the drain.
4
Filling the water circuit.
5
Filling the domestic hot water tank.
6
Insulating the water piping.
INFORMATION
For more information, see the installation manual of the
indoor unit and the installer reference guide.