background image

3 Preparation

Installation manual

3

EKV EKVSU260A
Daikin Altherma – Domestic hot water tank kit
4P449984-1B – 2016.11

3

Preparation

3.1

Preparing installation site

3.1.1

Installation site requirements of the
domestic hot water tank kit

INFORMATION

The domestic hot water tank kit is mounted into the indoor
unit. The use of tank kit EKVSU260A extends the height of
the indoor unit by 190 mm.

3.2

Preparing water piping

Respect the following water circuit requirements:

Domestic hot water tank kit – Clean pipes. 

Before installing the

domestic hot water tank kit,

 

all piping and fittings must be flushed

free  of  flux  and  debris.  Failure  to  do  this  may  cause  irreparable
damage  to  the  tank  kit  control  valves.  Flush  the  system  by
opening the hot water tap.

Domestic  hot  water  tank  kit  –  Drainage. 

For  the  discharge

piping  connected  to  the  pressure  relief  valve  of  the  domestic  hot
water tank kit, respect the following requirements:

Item

Requirement

Pressure relief valve diameter

15 mm

Discharge pipe diameter (to pressure relief valve)

15 mm

Discharge piping diameter (from tundish)

22 mm

Discharge piping material (from tundish)

Metal

Vertical length below tundish, before first elbow or
bend

≥300 mm

Continuous fall after first elbow or bend

≥1:200

Maximum resistance

(a)

≤9 m

Resistance created by each elbow or bend

0.8 m

(a)

The maximum allowed resistance (i.e. equivalent length) is
expressed as a length of straight pipe (i.e. no elbows or
bends).

INFORMATION

All piping MUST be installed according to section G3 of the
Building Regulations.

Domestic hot water tank kit – Pressure balancing. 

To prevent

large pressure differences at the taps and damage to the shower
valve due to high‑pressure cold water (5 bar), provide a dedicated
2‑bar feed to both cold water and hot water taps. To do this, also
connect  the  cold  water  supply  for  the  cold  water  taps  to  the
pressure reducing valve of the domestic hot water tank kit.

a

b

e

c

d

e

h

f

f

g

g

e

a

Cold water supply into house at 5 bar

b

To 5-bar taps

c

Pressure reducing valve (part of the domestic hot water
tank kit)

d

Indoor unit

e

Dedicated 2‑bar feed

f

Cold water taps

g

Hot water taps

Domestic  hot  water  tank  kit  –  Secondary  return. 

Where  the

secondary return circuits are used, an additional expansion vessel
may be required.

4

Installation

4.1

Opening the units

4.1.1

To open the indoor unit

1

Loosen and remove the 4 screws that fix the top panel.

2

Remove the top panel from the unit.

4.2

Connecting the water piping

4.2.1

To connect the water piping

NOTICE

Do  NOT  use  excessive  force  when  connecting  the  piping.
Deformation of the piping can cause malfunctioning of the
unit.

INFORMATION

If you have to inspect the inside of the domestic hot water
tank, you can access it via the booster heater boss.

The installation of the domestic hot water tank kit is part of a larger
installation flow. The total installation of the water piping consists of:

1

Connecting the recirculation piping.

2

Connecting the water piping:

▪ Directly  to  the  indoor  unit:  connecting  the  water  piping  to  the

space heating inlet, the space heating outlet, and the domestic
hot water outlet.

Via  the  domestic  hot  water  tank  kit:  connecting  the  water
piping  to  the  unit’s  domestic  cold  water  inlet,  and
connecting the kit itself to the drain.

3

Connecting the pressure relief valve to the drain.

4

Filling the water circuit.

5

Filling the domestic hot water tank.

6

Insulating the water piping.

INFORMATION

For  more  information,  see  the  installation  manual  of  the
indoor unit and the installer reference guide.

Summary of Contents for EKVSU260A

Page 1: ...Installation manual Daikin Altherma Domestic hot water tank kit English 180 l 260 l Installation manual Daikin Altherma Domestic hot water tank kit EKVSU180A EKVSU260A ...

Page 2: ...omestic hot water tank kit installation manual Installation instructions Format Paper in the box of the domestic hot water tank kit Installer reference guide Preparation of the installation good practices reference data Format Digital files on http www daikineurope com support and manuals product information Addendum book for optional equipment Additional info about how to install optional equipme...

Page 3: ...lve due to high pressure cold water 5 bar provide a dedicated 2 bar feed to both cold water and hot water taps To do this also connect the cold water supply for the cold water taps to the pressure reducing valve of the domestic hot water tank kit a b e c d e h f f g g e a Cold water supply into house at 5 bar b To 5 bar taps c Pressure reducing valve part of the domestic hot water tank kit d Indoo...

Page 4: ...s These shut off valves are field supplied 2 Screw the indoor unit nuts on the shut off valves 3 Connect the domestic hot water out pipe to the indoor unit Via the domestic hot water tank kit 4 Mount the indoor unit height extension that is part of the kit EKVSU260A only 4 5 Mount the domestic hot water tank kit 180 l 260 l 6 Route the flexible hoses of the domestic hot water tank kit according to...

Page 5: ...Regulation G3 section 3 61 gives alternative points of discharge 600 mm 300 mm a D1 D2 c b d a Safety device pressure relief valve of domestic hot water tank pressure relief valve of domestic hot water tank kit b Tundish c Fixed grating d Trapped gully D1 Metal discharge pipe from safety device to tundish D2 Discharge pipe from tundish with continuous fall See Building Regulation G3 section 3 56 T...

Page 6: ......